The DOI matches its Crossref record.
The Behavior of Human Mesenchymal Stem Cells in 3D Fibrin Clots: Dependence on Fibrinogen Concentration and Clot Structure
Abstract
Natural biopolymers such as human fibrin are appealing to tissue engineers, because fibrin is biocompatible, bioresorbable, and essential in normal wound healing. There have been numerous studies to date to develop a fibrin-based injectable cell delivery system, albeit with varying success. We propose that the outcome of fibrin cell delivery can, in part, be attributed to the relative concentrations of fibrinogen and thrombin solutions (i.e., formulations) and the structure of the final 3D fibrin clot. Formulation-dependent proliferation of human mesenchymal stem cells (hMSCs) within 3D fibrin clots was investigated in vitro. Our results indicate that hMSCs are viable in all fibrin sealant formulations investigated, and proliferation rates vary with fibrin formulations. Furthermore, the fibrinogen solution, not thrombin, was found to have a more dominant role on hMSC proliferation, with dilute fibrinogen solutions promoting greater hMSC proliferation. Confocal and electron microscopy reveal formulation dependence on 3D fibrin clot structure, with dilute fibrinogen solutions yielding more open, homogeneous microstructures. This study suggests that the concentrations of fibrinogen and thrombin solutions must be carefully considered for cell delivery because they affect 3D fibrin clot structure and cell proliferation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Injectable and biodegradable hydrogels: gelation, biodegradation and biomedical applications
Li, Y., Rodrigues, J., & Tomás, H. (2012) · Chem. Soc. Rev. · doi:10.1039/c1cs15203c · Cited by 1,445
Malafaya, P. B., Silva, G. A., & Reis, R. L. (2007) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2007.03.012 · Cited by 1,401
Falanga, V., Iwamoto, S., Chartier, M., Yufit, T., Butmarc, J., Kouttab, N., Shrayer, D., & Carson, P. (2007) · Tissue Engineering · doi:10.1089/ten.2006.0278 · Cited by 783
Strategies and Molecular Design Criteria for 3D Printable Hydrogels
Jungst, T., Smolan, W., Schacht, K., Scheibel, T., & Groll, J. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00303 · Cited by 712
A review of fibrin and fibrin composites for bone tissue engineering
Noori, A., Ashrafi, S. J., Vaez-Ghaemi, R., Hatamian-Zaremi, A., & Webster, T. J. (2017) · International Journal of Nanomedicine · doi:10.2147/ijn.s124671 · Cited by 458
Metadata
- Authors
- Ho, W., Tawil, B., Dunn, J. C. Y., & Wu, B. M.
- Venue
- Tissue Engineering
- Publisher
- SAGE Publications
- Published
- 2006-06
- Volume
- 12
- Issue
- 6
- Pages
- 1587-1595
- ISSN
- 1076-3279 (ISSN-L)
- 1557-8690
- OpenAlex
- W2055495773
- Cited by
- 232
- References
- 0
- FWCI
- 8.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Behavior of Human Mesenchymal Stem Cells in 3D Fibrin Clots: Dependence on Fibrinogen Concentration and Clot Structure. https://app.cochat.ai/papers/10.1089/ten.2006.12.1587
- The paper
- Ho, W., Tawil, B., Dunn, J. C. Y., & Wu, B. M. (2006). The Behavior of Human Mesenchymal Stem Cells in 3D Fibrin Clots: Dependence on Fibrinogen Concentration and Clot Structure. Tissue Engineering. https://doi.org/10.1089/ten.2006.12.1587
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.