The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Bioreactors for Tissue Engineering: Focus on Mechanical Constraints. A Comparative Review
Abstract
Considering the current techniques in cell culture, the stimulation of cellular proliferation and the formation of bidimensional tissues such as skin are widely performed in academic and industrial research laboratories. However, the formation of cohesive, organized, and functional tissues by three-dimensional (3D) cell culture is complex. A suitable environment is required, which is achieved and maintained in a specific bioreactor, a device that reproduces the physiological environment (including biochemical and mechanical functions) specific to the tissue that is to be regenerated. Bioreactors can also be used to apply mechanical constraints during maturation of the regenerating tissue for studying and understanding the mechanical factors influencing tissue regeneration. In this work, the main types of bioreactors used for tissue engineering and regeneration, as well as their most common applications, were reviewed and compared. The importance of the mechanical properties applied to the scaffolds and the regenerating constructs has been often neglected. This review focused on the influence of mechanical stresses and strains during the culture period that leads to the final mechanical properties of the construct.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Controlling the Cellular Organization of Tissue‐Engineered Cardiac Constructs
GONEN‐WADMANY, M., GEPSTEIN, L., & SELIKTAR, D. (2004) · Annals of the New York Academy of Sciences · doi:10.1196/annals.1302.025 · Cited by 56
Cited by
Oh, S. H., Park, I. K., Kim, J. M., & Lee, J. H. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2006.11.024 · Cited by 713
Chang, R., Nam, J., & Sun, W. (2008) · Tissue Engineering Part A · doi:10.1089/ten.a.2007.0004 · Cited by 549
Small-diameter vascular tissue engineering
Seifu, D. G., Purnama, A., Mequanint, K., & Mantovani, D. (2013) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2013.77 · Cited by 501
Self-citationBiomaterials in cardiac tissue engineering: Ten years of research survey
Chen, Q.-Z., Harding, S. E., Ali, N. N., Lyon, A. R., & Boccaccini, A. R. (2008) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2007.08.001 · Cited by 382
Bone tissue engineering bioreactors: Dynamic culture and the influence of shear stress
Yeatts, A. B., & Fisher, J. P. (2011) · Bone · doi:10.1016/j.bone.2010.09.138 · Cited by 298
Metadata
- Authors
- Bilodeau, K., & Mantovani, D.
- Venue
- Tissue Engineering
- Publisher
- SAGE Publications
- Published
- 2006-08
- Volume
- 12
- Issue
- 8
- Pages
- 2367-2383
- ISSN
- 1076-3279 (ISSN-L)
- 1557-8690
- OpenAlex
- W2051075021
- Cited by
- 170
- References
- 1
- FWCI
- 10.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Bioreactors for Tissue Engineering: Focus on Mechanical Constraints. A Comparative Review. https://app.cochat.ai/papers/10.1089/ten.2006.12.2367
- The paper
- Bilodeau, K., & Mantovani, D. (2006). Bioreactors for Tissue Engineering: Focus on Mechanical Constraints. A Comparative Review. Tissue Engineering. https://doi.org/10.1089/ten.2006.12.2367
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.