Cited by 160

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

In Vivo Remodeling and Structural Characterization of Fibrin-Based Tissue-Engineered Heart Valves in the Adult Sheep Model

Flanagan, Thomas C., Sachweh, Jörg S., Frese, Julia, Schnöring, Heike, Gronloh, Nina, Koch, Sabine, Tolba, Rene H., Schmitz-Rode, Thomas, Jockenhoevel, Stefan·2009·Tissue Engineering Part A

Abstract

Autologous fibrin-based tissue-engineered heart valves have demonstrated excellent potential as patient-derived valve replacements. The present pilot study aims to evaluate the structure and mechanical durability of fibrin-based heart valves after implantation in a large-animal model (sheep). Tissue-engineered heart valves were molded using a fibrin scaffold and autologous arterial-derived cells before 28 days of mechanical conditioning. Conditioned valves were subsequently implanted in the pulmonary trunk of the same animals from which the cells were harvested. After 3 months in vivo , explanted valve conduits (n = 4) had remained intact and exhibited native tissue consistency, although leaflets demonstrated insufficiency because of tissue contraction. Routine histology showed remarkable tissue development and cell distribution, along with functional blood vessel ingrowth. A confluent monolayer of endothelial cells was present on the valve surface, as evidenced by scanning electron microscopy and positive von Willebrand factor staining. Immunohistochemistry and extracellular matrix (ECM) assay demonstrated complete resorption of the fibrin scaffold and replacement with ECM proteins. Transmission electron microscopy revealed mature collagen formation and viable, active resident tissue cells. The preliminary findings of implanted fibrin-based tissue-engineered heart valves are encouraging, with excellent tissue remodeling and structural durability after 3 months in vivo . The results from this pilot study highlight the potential for construction of completely “autologous” customized tissue-engineered heart valves based on a patient-derived fibrin scaffold.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/ten.tea.2009.0018

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 160

Metadata

Authors
Flanagan, T. C., Sachweh, J. S., Frese, J., Schnöring, H., Gronloh, N., Koch, S., Tolba, R. H., Schmitz-Rode, T., & Jockenhoevel, S.
Venue
Tissue Engineering Part A
Published
2009-05-05
Volume
15
Issue
10
Pages
2965-2976
ISSN
  • 1937-3341 (ISSN-L)
  • 1937-335X
OpenAlex
W2035419918
Cited by
160
References
1
FWCI
11.38
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: In Vivo Remodeling and Structural Characterization of Fibrin-Based Tissue-Engineered Heart Valves in the Adult Sheep Model. https://app.cochat.ai/papers/10.1089/ten.tea.2009.0018
The paper
Flanagan, T. C., Sachweh, J. S., Frese, J., Schnöring, H., Gronloh, N., Koch, S., Tolba, R. H., Schmitz-Rode, T., & Jockenhoevel, S. (2009). In Vivo Remodeling and Structural Characterization of Fibrin-Based Tissue-Engineered Heart Valves in the Adult Sheep Model. Tissue Engineering Part A. https://doi.org/10.1089/ten.tea.2009.0018

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.