Comparison of Poly( l -lactide-co-ɛ-caprolactone) and Poly(trimethylene carbonate) Membranes for Urethral Regeneration: An In Vitro and In Vivo Study
Open accessThe DOI matches its Crossref record.
Abstract
Urethral defects are normally reconstructed using a patient's own genital tissue; however, in severe cases, additional grafts are needed. We studied the suitability of poly(l-lactide-co-ɛ-caprolactone) (PLCL) and poly(trimethylene carbonate) (PTMC) membranes for urethral reconstruction in vivo. Further, the compatibility of the materials was evaluated in vitro with human urothelial cells (hUCs). The attachment and viability of hUCs and the expression of different urothelial cell markers (cytokeratin 7, 8, 19, and uroplakin Ia, Ib, and III) were studied after in vitro cell culture on PLCL and PTMC. For the in vivo study, 32 rabbits were divided into the PLCL (n = 15), PTMC (n = 15), and control or sham surgery (n = 2) groups. An oval urethral defect 1 × 2 cm in size was surgically excised and replaced with a PLCL or a PTMC membrane or urethral mucosa in sham surgery group. The rabbits were followed for 2, 4, and 16 weeks. After the follow-up, urethrography was performed to check the patency of the urethra. The defect area was excised for histological examination, where the epithelial integrity and structure, inflammation, and fibrosis were observed. There was no notable difference on hUCs attachment on PLCL and PTMC membranes after 1 day of cell seeding, further, the majority of hUCs were viable and maintained their urothelial phenotype on both biomaterials. Postoperatively, animals recovered well, and no severe strictures were discovered by urethrography. In histological examination, the urothelial integrity and structure developed toward a normal urothelium with only mild signs of fibrosis or inflammation. According to these results, PLCL and PTMC are both suitable for reconstructing urethral defects. There were no explicit differences between the PLCL and PTMC membranes. However, PTMC membranes were more flexible, easier to suture and shape, and developed significant epithelial integrity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Liu, X., Liu, S., Li, K., Fan, Y., Feng, S., Peng, L., Zhang, T., Wang, X., Chen, D., Xiong, C., et al. (2021) · Colloids and Surfaces A: Physicochemical and Engineering Aspects · doi:10.1016/j.colsurfa.2021.127550 · Cited by 24
Liu, X., Liu, S., Fan, Y., Qi, J., Wang, X., Bai, W., Chen, D., Xiong, C., & Zhang, L. (2021) · Journal of Industrial and Engineering Chemistry · doi:10.1016/j.jiec.2021.08.014 · Cited by 13
Liu, X., Liu, S., Feng, S., Wang, X., Bai, W., Xiao, J., Chen, D., Xiong, C., & Zhang, L. (2021) · Journal of Polymer Research · doi:10.1007/s10965-021-02802-9 · Cited by 11
Soft, Formstable (Co)Polyester Blend Elastomers
Neffe, A., Izraylit, V., Hommes-Schattmann, P., & Lendlein, A. (2021) · Nanomaterials · doi:10.3390/nano11061472 · Cited by 9
Kurki, A., Hannula, M., Miettinen, S., Teittinen, H., Paakinaho, K., Hyttinen, J., Lindén, J., & Sartoneva, R. (2025) · Regenerative Biomaterials · doi:10.1093/rb/rbaf097 · Cited by 3
Self-citation
Metadata
- Authors
- Sartoneva, R., Nordback, P. H., Haimi, S., Grijpma, D. W., Lehto, K., Rooney, N., Seppänen-Kaijansinkko, R., Miettinen, S., & Lahdes-Vasama, T.
- Venue
- Tissue Engineering Part A
- Publisher
- SAGE Publications
- Published
- 2018-01
- Volume
- 24
- Issue
- 1-2
- Pages
- 117-127
- ISSN
- 1937-3341 (ISSN-L)
- 1937-335X
- OpenAlex
- W2610163652
- Cited by
- 33
- References
- 0
- FWCI
- 2.02
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.