The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Rapid Prototyping: Porous Titanium Alloy Scaffolds Produced by Selective Laser Melting for Bone Tissue Engineering
Abstract
Selective laser melting (SLM), a method used in the nuclear, space, and racing industries, allows the creation of customized titanium alloy scaffolds with highly defined external shape and internal structure using rapid prototyping as supporting external structures within which bone tissue can grow. Human osteoblasts were cultured on SLM-produced Ti6Al4V mesh scaffolds to demonstrate biocompatibility using scanning electron microscopy (SEM), fluorescence microscopy after cell vitality staining, and common biocompatibility tests (lactate dihydrogenase (LDH), 3-(4,5-dimethylthiazol-2-yl)-2, 5-diphenyltetrazolium bromide (MTT), 5-bromo-2-deoxyuridine (BrdU), and water soluble tetrazolium (WST)). Cell occlusion of pores of different widths (0.45-1.2 mm) was evaluated. Scaffolds were tested for resistance to compressive force. SEM investigations showed osteoblasts with well-spread morphology and multiple contact points. Cell vitality staining and biocompatibility tests confirmed osteoblast vitality and proliferation on the scaffolds. Pore overgrowth increased during 6 weeks' culture at pore widths of 0.45 and 0.5 mm, and in the course of 3 weeks for pore widths of 0.55, 0.6, and 0.7 mm. No pore occlusion was observed on pores of width 0.9-1.2 mm. Porosity and maximum compressive load at failure increased and decreased with increasing pore width, respectively. In summary, the scaffolds are biocompatible, and pore width influences pore overgrowth, resistance to compressive force, and porosity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Porosity of 3D biomaterial scaffolds and osteogenesis
Karageorgiou, V., & Kaplan, D. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2005.02.002 · Cited by 6,622
Scaffolds in tissue engineering bone and cartilage
Hutmacher, D. W. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00121-6 · Cited by 4,994
Bone tissue engineering using polycaprolactone scaffolds fabricated via selective laser sintering
Williams, J. M., Adewunmi, A., Schek, R. M., Flanagan, C. L., Krebsbach, P. H., Feinberg, S. E., Hollister, S. J., & Das, S. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.11.057 · Cited by 1,563
Fabrication methods of porous metals for use in orthopaedic applications
Ryan, G., Pandit, A., & Apatsidis, D. P. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.12.002 · Cited by 1,391
Effect of Pore Size and Void Fraction on Cellular Adhesion, Proliferation, and Matrix Deposition
Zeltinger, J., Sherwood, J. K., Graham, D. A., Müeller, R., & Griffith, L. G. (2001) · Tissue Engineering · doi:10.1089/107632701753213183 · Cited by 794
Growth and transplantation of a custom vascularised bone graft in a man
Warnke, P., Springer, I., Wiltfang, J., Acil, Y., Eufinger, H., Wehmöller, M., Russo, P., Bolte, H., Sherry, E., Behrens, E., et al. (2004) · The Lancet · doi:10.1016/s0140-6736(04)16935-3 · Cited by 717
Self-citationHollister, S. J., Maddox, R. D., & Taboas, J. M. (2002) · Biomaterials · doi:10.1016/s0142-9612(02)00148-5 · Cited by 715
Taboas, J. M., Maddox, R. D., Krebsbach, P. H., & Hollister, S. J. (2003) · Biomaterials · doi:10.1016/s0142-9612(02)00276-4 · Cited by 691
Osteoconduction at porous hydroxyapatite with various pore configurations
Chang, B.-S., Lee, >. K. >.-K., Hong, K.-S., Youn, H.-J., Ryu, H.-S., Chung, S.-S., & Park, K.-W. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00030-2 · Cited by 635
Mechanical and in vivo performance of hydroxyapatite implants with controlled architectures
Chu, T.-M. G., Orton, D. G., Hollister, S. J., Feinberg, S. E., & Halloran, J. W. (2002) · Biomaterials · doi:10.1016/s0142-9612(01)00243-5 · Cited by 554
Hollander, D. A., von Walter, M., Wirtz, T., Sellei, R., Schmidt-Rohlfing, B., Paar, O., & Erli, H.-J. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.07.041 · Cited by 482
Processing and biocompatibility evaluation of laser processed porous titanium
Xue, W., Krishna, B. V., Bandyopadhyay, A., & Bose, S. (2007) · Acta Biomaterialia · doi:10.1016/j.actbio.2007.05.009 · Cited by 471
Ceramic components manufacturing by selective laser sintering
Bertrand, P., Bayle, F., Combe, C., Goeuriot, P., & Smurov, I. (2007) · Applied Surface Science · doi:10.1016/j.apsusc.2007.08.085 · Cited by 351
Computer‐aided tissue engineering: overview, scope and challenges
Sun, W., Darling, A., Starly, B., & Nam, J. (2004) · Biotechnology and Applied Biochemistry · doi:10.1042/ba20030108 · Cited by 341
Characterization of porous hydroxyapatite
Hing, K. A., Best, S. M., & Bonfield, W. (1999) · Journal of Materials Science Materials in Medicine · doi:10.1023/a:1008929305897 · Cited by 323
Flexible manufacturing of metallic products by selective laser melting of powder
Osakada, K., & Shiomi, M. (2006) · International Journal of Machine Tools and Manufacture · doi:10.1016/j.ijmachtools.2006.01.024 · Cited by 294
Processing and mechanical properties of autogenous titanium implant materials
Wen, C. E., Yamada, Y., Shimojima, K., Chino, Y., Asahina, T., & Mabuchi, M. (2002) · Journal of Materials Science: Materials in Medicine · doi:10.1023/a:1014344819558 · Cited by 254
Human articular chondrocyte adhesion and proliferation on synthetic biodegradable polymer films
Ishaug-Riley, S. (1999) · Biomaterials · doi:10.1016/s0142-9612(99)00155-6 · Cited by 235
Sun, W., Starly, B., Darling, A., & Gomez, C. (2004) · Biotechnology and Applied Biochemistry · doi:10.1042/ba20030109 · Cited by 223
Xu, L., Zhang, E., Yin, D., Zeng, S., & Yang, K. (2008) · Journal of Materials Science: Materials in Medicine · doi:10.1007/s10856-007-3219-y · Cited by 209
Smooth muscle cell adhesion to tissue engineering scaffolds
Nikolovski, J., & Mooney, D. J. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00079-x · Cited by 150
Wu, Y., SHAW, S., Lin, H., LEE, T., & YANG, C. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2005.07.002 · Cited by 143
Rochus, P., Plesseria, J.-Y., Van Elsen, M., Kruth, J.-P., Carrus, R., & Dormal, T. (2007) · Acta Astronautica · doi:10.1016/j.actaastro.2007.01.004 · Cited by 141
Santos, E. C., Osakada, K., Shiomi, M., Kitamura, Y., & Abe, F. (2004) · Proceedings of the Institution of Mechanical Engineers Part C Journal of Mechanical Engineering Science · doi:10.1243/0954406041319545 · Cited by 116
Selective Laser Sintering of SiC/Polyamide Composites
Hon, K. K. B., & Gill, T. (2003) · CIRP Annals · doi:10.1016/s0007-8506(07)60558-7 · Cited by 110
Geometry of Porous Hydroxyapatite Implants Influences Osteogenesis in Baboons {Papio ursinus)
Magan, A., & Ripamonti, U. (1996) · Journal of Craniofacial Surgery · doi:10.1097/00001665-199601000-00016 · Cited by 85
Pamuła, E., Bačáková, L., Filová, E., Buczyńska, J., Dobrzyński, P., Nosková, L., & Grausová, Ľ. (2007) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-007-3001-1 · Cited by 76
Implant design and production—a new approach by selective laser melting
Wehmöller, M., Warnke, P. H., Zilian, C., & Eufinger, H. (2005) · International Congress Series · doi:10.1016/j.ics.2005.03.155 · Cited by 70
Self-citationYadroitsev, I. A., Bertrand, P., Laget, B., & Smurov, I. Y. (2007) · Journal of Nuclear Materials · doi:10.1016/j.jnucmat.2007.01.078 · Cited by 64
Properties of Titanium Dental Implant Models Made by Laser Processing
Laoui, T., Santos, E. C., Osakada, K., Shiomi, M., Morita, M., Shaik, S. K., Толочко, Н. К., Abe, F., & Takahashi, M. (2006) · Proceedings of the Institution of Mechanical Engineers Part C Journal of Mechanical Engineering Science · doi:10.1243/09544062jmes133 · Cited by 47
Li, J., de Wijn, J. R., van Blitterswijk, C., & de Groot, K. (2005) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-005-4723-6 · Cited by 44
Hydroxyapatite (HA) bone scaffolds with controlled macrochannel pores
Bae, C., Kim, H., Kim, H.-W., et al. (2006) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-006-8934-2 · Cited by 43
Cited by
Review of selective laser melting: Materials and applications
Yap, C. Y., Chua, C. K., Dong, Z. L., Liu, Z. H., Zhang, D. Q., Loh, L. E., & Sing, S. L. (2015) · Applied Physics Reviews · doi:10.1063/1.4935926 · Cited by 2,353
Normal Bone Anatomy and Physiology
Clarke, B. (2008) · Clinical Journal of the American Society of Nephrology · doi:10.2215/cjn.04151206 · Cited by 2,192
Zhang, L., & Attar, H. (2016) · Advanced Engineering Materials · doi:10.1002/adem.201500419 · Cited by 721
Surface Morphology in Selective Laser Melting of Metal Powders
Yadroitsev, I., & Smurov, I. (2011) · Physics Procedia · doi:10.1016/j.phpro.2011.03.034 · Cited by 349
Microstructure and mechanical behavior of porous Ti–6Al–4V parts obtained by selective laser melting
Sallica-Leva, E., Jardini, A. L., & Fogagnolo, J. B. (2013) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2013.05.011 · Cited by 340
Metadata
- Authors
- Warnke, P. H., Douglas, T., Wollny, P., Sherry, E., Steiner, M., Galonska, S., Becker, S. T., Springer, I. N., Wiltfang, J., & Sivananthan, S.
- Venue
- Tissue Engineering Part C: Methods
- Publisher
- SAGE Publications
- Published
- 2009-06
- Volume
- 15
- Issue
- 2
- Pages
- 115-124
- ISSN
- 1937-3384 (ISSN-L)
- 1937-3392
- OpenAlex
- W2082301825
- Cited by
- 305
- References
- 32
- FWCI
- 2.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.