CoChat

Simultaneous Measurement of Free Thyroxine and Free 3,5,3′-Triiodothyronine in Undiluted Serum by Direct Equilibrium Dialysis/Radioimmunoassay: Evidence that Free Triiodothyronine and Free Thyroxine are Normal in Many Patients with the Low Triiodothyronine Syndrome

CHOPRA, INDER J. · 1998 · Thyroid
Cited by 62

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

UNLABELLED: We have devised a practical, sensitive and specific method for simultaneous measurement of free thyroxine (FT4) and free triiodothyronine (FT3) in undiluted serum by direct equilibrium dialysis radioimmunoassay (RIA). Two hundred microliters serum sample was dialyzed against buffer (pH 7.4) for 20 hours at 37 degrees C and approximately 800 microL of the dialysate was used for measuring FT4 and FT3 simultaneously. The assay was set up in polystyrene tubes coated with anti-T4 antibody and available commercially for FT4 measurement (Quest-Nichols Institute, San Juan Capistrano, CA). The mean +/- SE (range) FT4 concentration (ng/dL) was 1.2 +/- 0.04 (0.7.0 to 2.30) in 54 normal subjects. It was significantly increased (3.6 +/- 0.4 [1.8 to 9.6], n = 20) in hyperthyroidism and clearly decreased (0.40 +/- 0.04 [1.10 to 0.70], n = 26] in hypothyroidism. All nonthyroid illness (NTI) patients had normal FT4 except 3, 2 of whom were on amiodarone and 1 had received heparin. Serum FT4 concentration was minimally elevated in 18 newborn cord blood serum (1.40 +/- 0.08 [0.90 to 2.2], cf. normal p < .05). The mean serum FT3 concentration (pg/dL) was 285 +/- 10 (134 to 454) in 54 normal sera. It was clearly increased in hyperthyroidism (1033 +/- 98 [593 to 2134], n = 20, p < .001). However, serum FT3 varied widely in hypothyroidism (27 to 597, mean 235 +/- 24, NS) as did serum total T3 (19 to 175). Interestingly, however, the mean serum FT3 concentration was normal (273 +/- 28 [62 to 575, NS]) in 25 NTI patients. All of these patients had low serum total T3 (46 +/- 5.0 [10 to 84], ng/dL; normal 84 to 160, p < 0.001), while FT3 was clearly normal in 21 of 25 patients and low in the remaining 4 patients. Similarly, among 18 newborn cord blood sera serum FT3 concentration was normal in 15 and subnormal only in the remaining 3 while all had clearly subnormal total T3 (28 to 74 ng/dL). CONCLUSIONS: (1) A practical, sensitive, and specific assay for simultaneous measurement of FT4 and FT3 is described; (2) FT3 is consistently elevated in hyperthyroidism while FT4 is elevated in most (approximately 85%) cases; (3) FT4 is consistently decreased in hypothyroidism but FT3 varies widely; (4). Serum FT3 concentration is normal in approximately 83% of patients with the low T3 syndrome in NTI and newborn cord blood serum. These data suggest that normal FT3 may explain clinical euthyroidism in many patients with the low T3 syndrome.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/thy.1998.8.249

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 62

Metadata

Authors
CHOPRA, I. J.
Venue
Thyroid
Published
1998-03
Volume
8
Issue
3
Pages
249-257
ISSN
  • 1050-7256 (ISSN-L)
  • 1557-9077
OpenAlex
W2070681606
Cited by
62
References
3
FWCI
2.56
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Simultaneous Measurement of Free Thyroxine and Free 3,5,3′-Triiodothyronine in Undiluted Serum by Direct Equilibrium Dialysis/Radioimmunoassay: Evidence that Free Triiodothyronine and Free Thyroxine are Normal in Many Patients with the Low Triiodothyronine Syndrome. https://app.cochat.ai/papers/10.1089/thy.1998.8.249
The paper
CHOPRA, I. J. (1998). Simultaneous Measurement of Free Thyroxine and Free 3,5,3′-Triiodothyronine in Undiluted Serum by Direct Equilibrium Dialysis/Radioimmunoassay: Evidence that Free Triiodothyronine and Free Thyroxine are Normal in Many Patients with the Low Triiodothyronine Syndrome. Thyroid. https://doi.org/10.1089/thy.1998.8.249

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.