Accuracy of Free Thyroxine Measurements Across Natural Ranges of Thyroxine Binding to Serum Proteins
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Systemic inaccuracies, proportional to the concentrations of serum proteins and the thyroxine (T4) they carry, have been reported in direct free T4 immunoassays. However, analytical recoveries of free T4 have not been carefully examined in most current methods, and they have not previously been examined across the pathophysiological range of serum T4 binding. In the present study we investigated ranges of serum T4 binding using free and total T4 measurements from 1359 individuals. Carefully characterized, gravimetrically calibrated, serum-based free T4 test solutions were then prepared with a constant normal free T4 concentration (12 ng/L) and varied serum T4 binding (approximately 300:1 to 24,000:1, ng protein bound T4: ng free T4). These standardized test solutions were analyzed using five T4 analog based free T4 methods. Analytical recoveries were calculated as ratios of actual free T4 measurements to the target value, and expressed as a percent of the target. Analytical recoveries were directly proportional to the extent of serum T4 binding and ranged 2% to 155%, 25% to 131%, 53% to 106%, 37% to 93%, and 37% to 73%, lowest to highest, in different methods. These systemic inaccuracies will confound interpretations of free T4 test results in clinical conditions with altered T4 binding. Future investigations into free T4 status must examine the analytical recovery of the free T4 method(s) used, as they relate to the extent of serum T4 binding in the clinical condition(s) studied.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Radioimmunoassay for Measurement of Thyroxine in Unextracted Serum*
CHOPRA, I. J. (1972) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem-34-6-938 · Cited by 539
Applications of a New Chemiluminometric Thyrotropin Assay to Subnormal Measurement*
SPENCER, C. A., LoPRESTI, J. S., PATEL, A., GUTTLER, R. B., EIGEN, A., SHEN, D., GRAY, D., & NICOLOFF, J. T. (1990) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem-70-2-453 · Cited by 371 · cited 3×
“The competitive binding antithyroid microsomal antibody radioassay was in use for a time before the antithyroid peroxidase antibody ICMA was available.”
Direct determination of free thyroxin in undiluted serum by equilibrium dialysis/radioimmunoassay.
Nelson, J. C., & Tomei, R. T. (1988) · Clinical Chemistry · doi:10.1093/clinchem/34.9.1733 · Cited by 128
Self-citation
Cited by
Polybrominated Diphenyl Ether (PBDE) Flame Retardants and Thyroid Hormone during Pregnancy
Chevrier, J., Harley, K. G., Bradman, A., Gharbi, M., Sjödin, A., & Eskenazi, B. (2010) · Environmental Health Perspectives · doi:10.1289/ehp.1001905 · Cited by 297
De Groot, L. J. (2006) · Critical Care Clinics · doi:10.1016/j.ccc.2005.10.001 · Cited by 188
Tandem mass spectrometry improves the accuracy of free thyroxine measurements during pregnancy
Kahric-Janicic, N., Soldin, S. J., Soldin, O. P., West, T., Gu, J., & Jonklaas, J. (2007) · Thyroid · doi:10.1089/thy.2006.0303 · Cited by 166
“‘‘Outlier values’’ were specifically not excluded from any of the analyses because of the previously documented substantial disagreement between values obtained by different assays (28–30 ,”
Total and free thyroxine and triiodothyronine: measurement discrepancies, particularly in inpatients
Jonklaas, J., Sathasivam, A., Wang, H., Gu, J., Burman, K. D., & Soldin, S. J. (2014) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2014.06.007 · Cited by 40
Bliddal, S., Rasmussen, Å. K., Sundberg, K., Brocks, V., Skovbo, P., & Feldt-Rasmussen, U. (2011) · Thyroid · doi:10.1089/thy.2010.0286 · Cited by 24
“Either way, the estimates are influ-enced by the rise in TBG during pregnancy, and the use of trimester-specific reference ranges based on the specific laboratory method is essential (24,31–33).”
Metadata
- Authors
- Wang, R., Nelson, J. C., Weiss, R. M., & Wilcox, R. B.
- Venue
- Thyroid
- Publisher
- SAGE Publications
- Published
- 2000-01
- Volume
- 10
- Issue
- 1
- Pages
- 31-39
- ISSN
- 1050-7256 (ISSN-L)
- 1557-9077
- OpenAlex
- W2015768034
- Cited by
- 85
- References
- 3
- FWCI
- 2.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Accuracy of Free Thyroxine Measurements Across Natural Ranges of Thyroxine Binding to Serum Proteins. https://app.cochat.ai/papers/10.1089/thy.2000.10.31
- The paper
- Wang, R., Nelson, J. C., Weiss, R. M., & Wilcox, R. B. (2000). Accuracy of Free Thyroxine Measurements Across Natural Ranges of Thyroxine Binding to Serum Proteins. Thyroid. https://doi.org/10.1089/thy.2000.10.31
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.