Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 176

The DOI matches its Crossref record.

The Impact of Assessing Specimen Adequacy and Number of Needle Passes for Fine-Needle Aspiration Biopsy of Thyroid Nodules

Redman, Rachel, Zalaznick, Hillary, Mazzaferri, Ernest L., Massoll, Nicole A.·2006·Thyroid

Abstract

Fine-needle aspiration biopsy (FNAB) of thyroid nodules is a safe, cost-effective procedure but the rates of inadequate cytology specimens range from approximately 1% to 15%. This study tests the hypothesis that ultrasonographically (US) guided FNAB and onsite assessment of cytology improves the adequacy rate of FNAB. A retrospective analysis was performed on 693 thyroid FNAB specimens obtained with and without ultrasound guidance and with or without onsite cytology assessment. Overall, 29 specimens (4%) were inadequate for diagnosis. Among 163 cystic nodules and 530 solid nodules, inadequacy rates were 15% (n = 24) and 1% (n = 5) respectively (p = 0.0001). An onsite assessment of cytology for adequacy was done in 550 cases (83%), which was more accurately performed by a cytopathologist (97%) than a cytotechnologist (93%, p = 0.015). With US-guided FNAB, 3% of the cytology specimens were inadequate, compared to a 7% rate when US was not done (p = 0.003). The mean number of needle punctures necessary for an adequate specimen was 3.8 +/- 0.06 (median, 3.0; range, 1-11), which was different among various types of doctors, ranging from 3.2 +/- 0.07 to 5.4 +/- 0.12 (p = 0.001 analysis of variance [ANOVA]). The fewest number of needle passes to achieve an adequate specimen were required by university endocrinologists and pathologists working together (average, 3.2 +/- 0.07; median, 3.0; range, 1-11). Sample inadequacy rate varied significantly among physician groups, ranging from 3% to 18% (p = 0.0001 ANOVA). Stepwise regression analysis showed that onsite assessment of cytology, US-guided FNAB (p = 0.16), and cystic nature of the nodule (p < 0.0001 for all) correlated with adequacy of the specimen. We conclude that US-guided FNAB with onsite evaluation of cytology specimens substantially increases the adequacy of cytology specimens and decreases the number of required needle passes, which ultimately reduces patient discomfort and diagnostic errors, thus raising the question as to whether this should eventually become the standard of care. We believe this is a goal that training programs should strive to achieve.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/thy.2006.16.55

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 176

Metadata

Authors
Redman, R., Zalaznick, H., Mazzaferri, E. L., & Massoll, N. A.
Venue
Thyroid
Published
2006-01
Volume
16
Issue
1
Pages
55-60
ISSN
  • 1050-7256 (ISSN-L)
  • 1557-9077
OpenAlex
W2052925947
Cited by
176
References
0
FWCI
5.65
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Impact of Assessing Specimen Adequacy and Number of Needle Passes for Fine-Needle Aspiration Biopsy of Thyroid Nodules. https://app.cochat.ai/papers/10.1089/thy.2006.16.55
The paper
Redman, R., Zalaznick, H., Mazzaferri, E. L., & Massoll, N. A. (2006). The Impact of Assessing Specimen Adequacy and Number of Needle Passes for Fine-Needle Aspiration Biopsy of Thyroid Nodules. Thyroid. https://doi.org/10.1089/thy.2006.16.55

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.