CoChat

One Month Is Sufficient for Urinary Iodine to Return to Its Baseline Value After the Use of Water-Soluble Iodinated Contrast Agents in Post-Thyroidectomy Patients Requiring Radioiodine Therapy

Open access
Padovani, Rosália P., Kasamatsu, Teresa S., Nakabashi, Claudia C.D., Camacho, Cleber P., Andreoni, Danielle M., Malouf, Eduardo Z., Marone, Marilia M.S., Maciel, Rui M.B., Biscolla, Rosa Paula M. · 2012 · Thyroid
Cited by 127

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

BACKGROUND: There is a concern regarding the use of iodinated contrast agents (ICA) for chest and neck computed tomography (CT) to localize metastatases in patients with differentiated thyroid cancer (DTC). This is because the iodine in ICA can compete with (131)I and interfere with subsequent whole scans or radioactive iodine treatment. The required period for patients to eliminate the excess iodine is not clear. Therefore, knowing the period for iodine levels to return to baseline after the injection of ICA would permit a more reliable indication of CT for DTC patients. The most widely used marker to assess the plasmatic iodine pool is the urinary iodine (UI) concentration, which can be collected over a period of 24 hours (24U) or as a single-spot urinary sample (sU). As 24U collections are more difficult to perform, sU samples are preferable. It has not been established, however, if the measurement of iodine in sU is accurate for situations of excess iodine. METHODS: We evaluated 25 patients with DTC who received ICA to perform chest or neck CT. They collected 24U and sU urinary samples before the CT scan and 1 week and 1, 2, and 3 months after the test. UI was quantified by a semiautomated colorimetric method. RESULTS: Baseline median UI levels were 21.8 μg/dL for 24U and 26 μg/dL for sU. One week after ICA, UI median levels were very high for all patients, 800 μg/dL. One month after ICA, however, UI median levels returned to baseline in all patients, 19.0 μg/dL for 24U and 20 μg/dL for sU. Although the values of median UI obtained from sU and 24U samples were signicantly different, we observed a significant correlation between samples collected in 24U and sU in all evaluated periods. CONCLUSION: One month is required for UI to return to its baseline value after the use of ICA and for patients (after total thyroidectomy and radioiodine therapy) to eliminate the excess of iodine. In addition, sU samples, although not statistically similar to 24U values, can be used as a good marker to evaluate patients suspected of contamination with iodine.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/thy.2012.0099

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 127

Metadata

Authors
Padovani, R. P., Kasamatsu, T. S., Nakabashi, C. C. D., Camacho, C. P., Andreoni, D. M., Malouf, E. Z., Marone, M. M. S., Maciel, R. M. B., & Biscolla, R. P. M.
Venue
Thyroid
Published
2012-09
Volume
22
Issue
9
Pages
926-930
ISSN
  • 1050-7256 (ISSN-L)
  • 1557-9077
OpenAlex
W2154347411
Cited by
127
References
2
FWCI
7.36
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.