Comparing the Effectiveness of Telemedicine and Traditional Surveillance in Providing Diabetic Retinopathy Screening Examinations: A Randomized Controlled Trial
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To determine the effectiveness of telemedicine for providing diabetic retinopathy screening examinations compared with the effectiveness of traditional surveillance in community health clinics with a high proportion of minorities, including American Indian/Alaska Natives. SUBJECTS AND METHODS: We conducted a multicenter, randomized controlled trial and assigned diabetic participants to one of two groups: (1) telemedicine with a nonmydriatic camera or (2) traditional surveillance with an eye care provider. For those receiving telemedicine, the criteria for requiring follow-up with an eye care provider were (1) moderate nonproliferative diabetic retinopathy or higher, (2) presence of clinically significant macular edema, or (3) "unable to grade" result for diabetic retinopathy or macular edema. RESULTS: The telemedicine group (n=296) was more likely to receive a diabetic retinopathy screening examination within the first year of enrollment compared with the traditional surveillance group (n=271) (94% versus 56%, p<0.001). The overall prevalence of diabetic retinopathy at baseline was 21.4%, and macular edema was present in 1.4% of participants. In the telemedicine group, 20.5% would require further evaluation with an eye care provider, and 86% of these referrals were because of poor-quality digital images. CONCLUSIONS: Telemedicine using nonmydriatic cameras increased the proportion of participants who obtained diabetic retinopathy screening examinations, and most did not require follow-up with an eye care provider. Telemedicine may be a more effective way to screen patients for diabetic retinopathy and to triage further evaluation with an eye care provider. Methods to decrease poor quality imaging would improve the effectiveness of telemedicine for diabetic retinopathy screening examinations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Prevalence of Diabetic Retinopathy in the United States, 2005-2008
Zhang, X., Saaddine, J. B., Chou, C.-F., Cotch, M. F., Cheng, Y. J., Geiss, L. S., Gregg, E. W., Albright, A. L., Klein, B. E. K., & Klein, R. (2010) · JAMA · doi:10.1001/jama.2010.1111 · Cited by 1,196 · cited 1×
“38 However, we used ‘‘unable to determine’’ as the criteria for referral because most telemedicine protocols would recommend referral if the eye was unable to be examined with photographs.”
Diabetes mellitus in the Pima Indians: Incidence, risk factors and pathogenesis
Knowler, W. C., Pettitt, D. J., Saad, M. F., & Bennett, P. H. (1990) · Diabetes/Metabolism Reviews · doi:10.1002/dmr.5610060101 · Cited by 578
Research works printed but not linked: 34
- 10.2337/dc09-0459 · DOI · Paper page
- 10.2337/diaclin.27.4.140 · DOI · Paper page
- 10.1093/oxfordjournals.aje.a112648 · DOI · Paper page
- 10.1002/ajpa.1330620114 · DOI · Paper page
- 10.1001/archopht.1984.01040030398010 · DOI · Paper page
- 10.1056/NEJM199908263410907 · DOI · Paper page
- 10.1167/iovs.06-0107 · DOI · Paper page
- 10.1093/pubmed/fdn042 · DOI
- 10.1167/iovs.06-0934 · DOI
- 10.1016/1056-8727(92)90060-X · DOI
- 10.1016/S0002-9394(02)01522-2 · DOI · Paper page
- 10.2337/dc06-0295 · DOI · Paper page
- Hersh W, , Wallace J, , Patterson P et al. Telemedicine for the Medicare Population. Evidence Reports/Technology AssessmentsNumber 24Rockville, MD: Agency for Healthcare Research and Quality, 2001.
- Li HK, , Horton M, , Bursell SE et al. Telehealth practice recommendations for diabetic retinopathy. second Telemed J E Health, 2011; 17:814–837.
- Diabetic retinopathy study. Report number 6. Design, methods, and baseline results. Report Number 7. A modification of the Airlie House classification of diabetic retinopathy. Prepared by the Diabetic Retinopathy. Invest Ophthalmol Vis Sci, 1981; 21:1–226.
- Moss SE, , Meuer SM, , Klein R, , Hubbard LD, , Brothers RJ, , Klein BE. Are seven standard photographic fields necessary for classification of diabetic retinopathy? Invest Ophthalmol Vis Sci, 1989; 30:823–828.
- 10.1016/S0161-6420(00)00604-7 · DOI · Paper page
- 10.1016/S0161-6420(03)00475-5 · DOI · Paper page
- Grading diabetic retinopathy from stereoscopic color fundus photographs—An extension of the modified Airlie House classificationETDRS report number 10Early Treatment Diabetic Retinopathy Study Research Group. Ophthalmology, 1991; 98,5 Suppl:786–806.
- 10.1016/j.ajo.2005.03.075 · DOI
- 10.1016/S1262-3636(07)70142-8 · DOI
- 10.1016/S0008-4182(03)80111-4 · DOI
- 10.1164/ajrccm.164.10.2103068 · DOI
- 10.1001/archopht.1992.01080150079033 · DOI · Paper page
- 10.2307/2531248 · DOI · Paper page
- 10.4158/EP.13.3.260 · DOI
- American Diabetes Association. Executive summary: standards of medical care in diabetes—2009. Diabetes Care, 2009; 32,Suppl 1:S6–S12.
- 10.2307/2529310 · DOI · Paper page
- 10.1682/JRRD.2005.07.0117 · DOI · Paper page
- 10.2337/diacare.26.8.2476 · DOI
- 10.2337/diacare.28.2.318 · DOI · Paper page
- 10.2337/dc06-1509 · DOI · Paper page
- Virgili G, , Menchini F, , Murro V, , Peluso E, , Rosa F, , Casazza G. Optical coherence tomography (OCT) for detection of macular oedema in patients with diabetic retinopathy. Cochrane Database Syst Rev, 2011; 7:CD008081.
- 10.1159/000284351 · DOI
Cited by
Abràmoff, M. D., Lou, Y., Erginay, A., Clarida, W., Amelon, R., Folk, J. C., & Niemeijer, M. (2016) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.16-19964 · Cited by 1,101
Virgili, G., Menchini, F., Casazza, G., Hogg, R., Das, R. R., Wang, X., & Michelessi, M. (2015) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd008081.pub3 · Cited by 265
Mansberger, S. L., Sheppler, C., Barker, G., Gardiner, S. K., Demirel, S., Wooten, K., & Becker, T. M. (2015) · JAMA Ophthalmology · doi:10.1001/jamaophthalmol.2015.1 · Cited by 177
Self-citationGonçalves-Bradley, D. C., J Maria, A. R., Ricci-Cabello, I., Villanueva, G., Fønhus, M. S., Glenton, C., Lewin, S., Henschke, N., Buckley, B. S., Mehl, G. L., et al. (2020) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd012927.pub2 · Cited by 145
Gomez Rossi, J., Rojas-Perilla, N., Krois, J., & Schwendicke, F. (2022) · JAMA Network Open · doi:10.1001/jamanetworkopen.2022.0269 · Cited by 141
Metadata
- Authors
- Mansberger, S. L., Gleitsmann, K., Gardiner, S., Sheppler, C., Demirel, S., Wooten, K., & Becker, T. M.
- Venue
- Telemedicine and e-Health
- Publisher
- SAGE Publications
- Published
- 2013-12
- Volume
- 19
- Issue
- 12
- Pages
- 942-948
- ISSN
- 1530-5627 (ISSN-L)
- 1556-3669
- OpenAlex
- W2070976294
- Cited by
- 111
- References
- 2
- FWCI
- 8.82
- Type
- journal article
- Language
- en
- Open access
- green
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.