Nonmydriatic teleretinal imaging improves adherence to annual eye examinations in patients with diabetes
The DOI matches its Crossref record.
Abstract
We studied whether nonmydriatic digital retinal imaging with remote interpretation (teleretinal imaging) in the ambulatory care setting affected adherence to annual dilated eye examinations among patients with diabetes. We randomly assigned 448 patients to a teleretinal imaging group or a control group. We measured the number of patients who had dilated eye examinations within 12 months of group assignment and the agreement for level of diabetic retinopathy between teleretinal imaging and the eye examinations. The teleretinal imaging group (n = 223) had significantly more dilated eye examinations than the control group (n = 225). Teleretinal imaging and eye examination results showed significant correlation and moderate agreement. Cataract and smaller pupil size were significantly associated with ungradable retinal images. Two-thirds of patients with ungradable images had other ocular findings. Patients reported high satisfaction with nonmydriatic teleretinal imaging. Nonmydriatic teleretinal imaging improves diabetic retinopathy assessment rates.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Diabetic Retinopathy Preferred Practice Pattern®
Flaxel, C. J., Adelman, R. A., Bailey, S. T., Fawzi, A., Lim, J. I., Vemulakonda, G. A., & Ying, G.-S. (2020) · Ophthalmology · doi:10.1016/j.ophtha.2019.09.025 · Cited by 717
Detection of anaemia from retinal fundus images via deep learning
Mitani, A., Huang, A., Venugopalan, S., Corrado, G. S., Peng, L., Webster, D. R., Hammel, N., Liu, Y., & Varadarajan, A. V. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-019-0487-z · Cited by 230
Mansberger, S. L., Sheppler, C., Barker, G., Gardiner, S. K., Demirel, S., Wooten, K., & Becker, T. M. (2015) · JAMA Ophthalmology · doi:10.1001/jamaophthalmol.2015.1 · Cited by 177
Gonçalves-Bradley, D. C., J Maria, A. R., Ricci-Cabello, I., Villanueva, G., Fønhus, M. S., Glenton, C., Lewin, S., Henschke, N., Buckley, B. S., Mehl, G. L., et al. (2020) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd012927.pub2 · Cited by 145
Wolf, R. M., Channa, R., Liu, T. Y. A., Zehra, A., Bromberger, L., Patel, D., Ananthakrishnan, A., Brown, E. A., Prichett, L., Lehmann, H. P., et al. (2024) · Nature Communications · doi:10.1038/s41467-023-44676-z · Cited by 159
Metadata
- Authors
- Conlin, P. R., Fisch, B. M., Cavallerano, A. A., Cavallerano, J. D., Bursell, S.-E., & Aiello, L. M.
- Venue
- The Journal of Rehabilitation Research and Development
- Published
- 2006
- Volume
- 43
- Issue
- 6
- Pages
- 733
- ISSN
- 0742-3241 (ISSN-L)
- 0748-7711
- OpenAlex
- W2113035748
- Cited by
- 82
- References
- 0
- FWCI
- 1.92
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Nonmydriatic teleretinal imaging improves adherence to annual eye examinations in patients with diabetes. https://app.cochat.ai/papers/10.1682/jrrd.2005.07.0117
- The paper
- Conlin, P. R., Fisch, B. M., Cavallerano, A. A., Cavallerano, J. D., Bursell, S.-E., & Aiello, L. M. (2006). Nonmydriatic teleretinal imaging improves adherence to annual eye examinations in patients with diabetes. The Journal of Rehabilitation Research and Development. https://doi.org/10.1682/jrrd.2005.07.0117
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.