Validity and Reliability Evaluation of Four Commercial Activity Trackers' Step Counting Performance
Abstract
INTRODUCTION: Activity trackers are useful tools for physical rehabilitation purposes. Most available activity trackers are designed for fitness and wellness use, lacking in both accuracy and precision at lower speeds. Validity and reliability at all clinically relevant speeds are crucial selection criteria for use in clinical practice. The aim of this study was to assess the validity and reliability of four consumer-based activity trackers at clinical relevant walking speeds for patient groups undergoing rehabilitation. METHODS: The four commercial activity trackers Fitbit Surge (FS), Fitbit Charge HR (FC), Microsoft Band 2 (MB), and A&D 101NFC Activity Monitor (A&D) were evaluated at 2, 4, 4.5, and 5.5 km/h. Twenty healthy participants aged 25.6 ± 2 years walked on a treadmill at the four velocities in two trials of 100 steps each. Mean average percentage error (MAPE), intraclass correlation coefficient (ICC), and Bland-Altman 95% limits of agreement were calculated to assess validity and reliability. RESULTS: MAPE levels were between -8% and -6% for FS, -15% and 0% for MB, 7% and 21% for FC, and -53% and 1% for AD. The biggest inaccuracies were seen at 2 km/h, where AD underestimated by 53%. The highest accuracy was predominantly found with MB and AD, which overestimated ≤2% at velocities ≥4 km/h. ICC was moderate (0.73) for FS, good (0.88) for MB, moderate (0.52) for FC, and excellent (0.98) for AD. CONCLUSIONS: MB, FS, and AD accurately counted steps, when participants walked with velocities corresponding to a brisk walk (≥4 km/h). Walking at lower speeds (≤2 km/h) was not counted accurately. Thus, the four evaluated activity trackers are not useful for patient groups walking at lower speeds during rehabilitation, nor for counting indoor walking.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Two studies (13 comparisons) reported intradevice reliability for step count, with sample sizes of 20 and 24.
“Two studies (13 comparisons) reported on intradevice reliability for step count, with sample sizes of 20 [82] and 24 [150].”
From Reliability and Validity of Commercially Available Wearable Devices for Measuring Steps, Energy Expenditure, and Heart Rate: Systematic Review (2020) · cites this paper as [82]
The citation lists haven’t been fetched yet
References 17 · Cited by 18
- Authors
- Tophøj, K. H., Petersen, M. G., Sæbye, C., Baad-Hansen, T., & Wagner, S.
- Affiliations
- Aarhus University (DK)
- Aarhus University Hospital (DK)
- Department of Orthopedic Surgery, Aarhus University Hospital, Aarhus, Denmark.
- Corresponding author
- Petersen, Matilde Grøndahl
- Venue
- Telemedicine and e-Health
- Publisher
- SAGE Publications
- Published
- 2018-09
- Volume
- 24
- Issue
- 9
- Pages
- 669-677
- ISSN
- 1530-5627 (ISSN-L)
- 1556-3669
- OpenAlex
- W2781981952
- Cited by
- 18
- References
- 17
- Citations by year
- 2026: 1 · 2025: 1 · 2024: 1 · 2023: 2 · 2022: 2 · 2021: 6 · 2020: 3 · 2019: 2
- FWCI
- 1.90
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Telemedicine Journal and e-Health (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Physiology › Physical Activity and Health
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Health Sciences › Health Professions › General Health Professions › Mobile Health and mHealth Applications
- Keywords
- wearable activity trackers, step counting, wearable devices, walking speed, physical rehabilitation, device accuracy, Fitbit, treadmill walking, indoor walking, consumer health technology
- MeSH terms
- Walking Speed, Fitness Trackers, Adult, Female, Humans, Male, Reproducibility of Results, Walking, Young Adult, Accelerometry
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review