Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 300

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Reliability of measurement of muscle tone and muscle power in stroke patients

Gregson, J·2000·Age and Ageing

Abstract

OBJECTIVES: to establish the reliability of the modified Ashworth scale for measuring muscle tone in a range of muscle groups (elbow, wrist, knee and ankle; flexors and extensors) and of the Medical Research Council scale for measuring muscle power in the same muscle groups and their direct antagonists. DESIGN: a cross-sectional study involving repeated measures by two raters. We estimated reliability using the kappa statistic with quadratic weights (Kw). SETTING: an acute stroke ward, a stroke rehabilitation unit and a continuing care facility. SUBJECTS: people admitted to hospital with an acute stroke-35 patients, median age 73 (interquartile range 65-80), 20 men and 15 women. RESULTS: inter- and intra-rater agreement for the measurement of power was good to very good for all tested muscle groups (Kw = 0.84-0.96, Kw = 0.70-0.96). Inter- and intra-rater agreement for the measurement of tone in the elbow, wrist and knee flexors was good to very good (Kw = 0.73-0.96, Kw = 0.77-0.94). Inter- and intra-rater agreement for the measurement of tone in the ankle plantarflexors was moderate to good (Kw = 0.45-0.51, Kw = 0.59-0.64). CONCLUSIONS: the Medical Research Council scale was reliable in the tested muscle groups. The modified Ashworth scale demonstrated reliability in all tested muscle groups except the ankle plantarflexors. If reliable measurement of tone at the ankle is required for a specific purpose (e.g. to measure the effect of therapeutic intervention), further work will be necessary.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/ageing/29.3.223

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Cited by

See all 300

Metadata

Authors
Gregson, J.
Venue
Age and Ageing
Published
2000-05-01
Volume
29
Issue
3
Pages
223-228
ISSN
  • 0002-0729 (ISSN-L)
  • 1468-2834
OpenAlex
W2108793872
Cited by
300
References
9
FWCI
4.19
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Reliability of measurement of muscle tone and muscle power in stroke patients. https://app.cochat.ai/papers/10.1093/ageing/29.3.223
The paper
Gregson, J. (2000). Reliability of measurement of muscle tone and muscle power in stroke patients. Age and Ageing. https://doi.org/10.1093/ageing/29.3.223

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.