The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Computerised prescribing support still needs a human touch
Open accessAbstract
Sir, We wish to compliment O’Mahony et al. with the SENATOR trial [1]. Despite the non-significant results for the primary outcome, we believe the SENATOR findings are still relevant for clinical practice. Their statements on the clinical decision support system (CDSS) uptake align well with our own experiences regarding automated alerts. In the University Hospitals Leuven, patients have an electronic health record (EHR) and medication is prescribed using a computerised physician order entry system, which incorporates multiple CDSS modules [2]. Uptake of these CDSS modules into clinical practice is very low. For example, from June 2019 to May 2020, 21,990 CDSS alerts were generated for very severe drug–drug interactions, only 11.8% was accepted by attending physicians. In our opinion, major causes were the low specificity and low clinical relevance of the CDSS alerts, contributing to alert fatigue [3]. To better impact prescribing, a more specific and clinically relevant approach was needed. Hence, the ‘Check of Medication Appropriateness’ (CMA) service was developed in adjunct to the existing CDSS modules. The CMA concerns a centralised service comprising both a rule-based screening for potentially inappropriate prescriptions (PIP) as well as a medication review performed by trained clinical pharmacists. All clinical rules are derived from guideline recommendations and validated by a local multidisciplinary expert panel to further increase downstream uptake. Each clinical rule is provided with a dedicated flowchart to guarantee consistency when performing medication reviews. Finally, all pharmacist recommendations are provided directly in the EHR by adding notes addressing the treating physician [2]. In a first stand-alone (i.e. non-integrated) prototype of the CMA, EHRs were screened daily. Preliminary results showed a high number of recommendations for clinically relevant PIPs with an acceptance rate of 69.4% [2]. Optimization of the service then led to the development of the current CMA software, which is fully integrated into the hospital’s information system (HIS). The rule-based screening now runs continuously on real-time and dynamic patient data and is able to discern rapid changes, such as those of biochemical values. From June 2019 to May 2020, 6,137 recommendations were provided with an acceptance rate of 77.4%. In sum, we believe that the SENATOR software might surely be worth further study. We are convinced that two aspects are important to take into consideration for future investigations. First, the software should be integrated in the HIS, allowing a continuous screening using real-time patient data. Second, software-generated recommendations should be interpreted clinically for relevance and communicated to the attending physician by a specified trained person (e.g. a pharmacist). CDSS without a human interface might only be successful if it leads to a limited number of highly clinically relevant alerts for a well-defined patient population. Preferably, the implementation should also be supported by local consensus. None. None.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
There is added value of a secondary review of overridden DDI alerts by a specified trained person (e.g. a pharmacist).
“Moreover, it underlines the added value of a secondary review of overridden DDI alerts by a specified trained person (e.g. a pharmacist) [25].”
From Overall performance of a drug–drug interaction clinical decision support system: quantitative evaluation and end-user survey (2022) · cites this paper as [25]
In the letter’s “Sir” section (p. 1), the authors recommend that a specified trained person, such as a pharmacist, assess software-generated recommendations for clinical relevance. They also report low acceptance of severe drug–drug interaction alerts, but do not specifically describe a secondary review of alerts that physicians have overridden. (LLM, conf=0.87)
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
O’Mahony, D., Guðmundsson, A., Soiza, R. L., Petrović, M., Cruz-Jentoft, A. J., Cherubini, A., Fordham, R. J., Byrne, S., Dahly, D. L., Gallagher, P., et al. (2020) · Age and Ageing · doi:10.1093/ageing/afaa072 · Cited by 151
Quintens, C., Rijdt, T. D., Nieuwenhuyse, T. V., Simoens, S., Peetermans, W. E., den Bosch, B. V., Casteels, M., & Spriet, I. (2019) · BMC Medical Informatics and Decision Making · doi:10.1186/s12911-019-0748-5 · Cited by 62
Self-citationAverting Alert Fatigue to Prevent Adverse Drug Reactions
Carroll, A. E. (2019) · JAMA · doi:10.1001/jama.2019.11710 · Cited by 37
Flagged first, then by citations
Cited by
Sorted by citations
Van De Sijpe, G., Quintens, C., Walgraeve, K., Van Laer, E., Penny, J., De Vlieger, G., Schrijvers, R., De Munter, P., Foulon, V., Casteels, M., et al. (2022) · BMC Medical Informatics and Decision Making · doi:10.1186/s12911-022-01783-z · Cited by 54
Self-citation
Metadata
- Authors
- Quintens, C., Van de Sijpe, G., Van der Linden, L., & Spriet, I.
- Affiliations
- Universitair Ziekenhuis Leuven (BE)
- Department of Pharmaceutical and Pharmacological Sciences, KU Leuven, Leuven, Belgium
- Corresponding author
- Quintens, Charlotte
- Venue
- Age and Ageing
- Publisher
- Oxford University Press (OUP)
- Published
- 2020-09-30
- Volume
- 50
- Issue
- 6
- Pages
- e3-e4
- ISSN
- 0002-0729 (ISSN-L)
- 1468-2834
- OpenAlex
- W3089528937
- Cited by
- 22
- References
- 3
- Citations by year
- 2025: 2 · 2024: 1 · 2023: 2 · 2022: 12 · 2021: 3 · 2020: 2
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- academic.oup.com/journals/pages/open_access/funder_policies/chorus/standard_publication_model (vor)
- Locations
- Age and Ageing (publishedVersion)
- PubMed (publishedVersion)
- Lirias (KU Leuven) (acceptedVersion)
- Lirias (submittedVersion)
- Topics
- Health Sciences › Health Professions › Health Information Management › Electronic Health Records Systems
- Health Sciences › Medicine › Geriatrics and Gerontology › Pharmaceutical Practices and Patient Outcomes
- Health Sciences › Medicine › Health Informatics › Artificial Intelligence in Healthcare and Education
- Keywords
- clinical decision support systems, potentially inappropriate prescribing, medication review, clinical pharmacists, alarm fatigue, electronic health records, hospital information systems, real-time patient data, drug-drug interactions
- MeSH terms
- Potentially Inappropriate Medication List, Humans, Touch, Inappropriate Prescribing
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review