Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 262

The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.

Validation of a new pediatric air-displacement plethysmograph for assessing body composition in infants

Open access
Ma, Guansheng, Yao, Manjiang, Liu, Yan, Lin, Aiwei, Zou, Hui, Urlando, Alessandro, Wong, William W, Nommsen-Rivers, Laurie, Dewey, Kathryn G·2004·The American Journal of Clinical Nutrition

Abstract

BACKGROUND The accurate measurement of body composition is useful in assessments of infant growth and nutritional status. OBJECTIVE This study evaluated the reliability and accuracy of a new air-displacement plethysmography (ADP) system for body-composition assessment in infants. DESIGN Between- and within-day reliability was assessed by comparing the percentage body fat (%BF) obtained on consecutive days and on the same day, respectively, in 36 full-term infants. Accuracy was assessed by comparing %BF measured with the use of ADP and %BF measured with the use of deuterium (2H2O) dilution in 53 infants. RESULTS There were no significant differences in %BF between days (-0.50 +/- 1.21%BF) or within days (0.16 +/- 1.44%BF). Mean between- and within-day test-retest SDs of 0.69 and 0.72%BF, respectively, indicated excellent reliability. The %BF measurements obtained by using ADP were not significantly influenced by infant behavioral state. Mean %BF obtained by using ADP (20.32%BF) did not differ significantly from that obtained by using 2H2O dilution (20.39%BF), and the regression line [%BF(2H2O) = 0.851%BF (ADP) + 3.094] gave a high R2 (0.76) and a low SEE (3.26). The 95% limits of agreement between ADP and 2H2O (-6.84%BF, 6.71%BF) were narrower than those reported for other body-composition techniques used in infants. Individual differences between the 2 methods were not a function of body mass or fatness. CONCLUSION ADP is a reliable and accurate instrument for determining %BF in infants, and it has the potential for use in both research and clinical settings.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/ajcn/79.4.653

Cites

32 of 32 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 262

Metadata

Authors
Ma, G., Yao, M., Liu, Y., Lin, A., Zou, H., Urlando, A., Wong, W. W., Nommsen-Rivers, L., & Dewey, K. G.
Venue
The American Journal of Clinical Nutrition
Publisher
Elsevier BV
Published
2004-04
Volume
79
Issue
4
Pages
653-660
ISSN
0002-9165 (ISSN-L)
OpenAlex
W2114843449
Cited by
262
References
32
FWCI
2.09
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.