Heterophilic Antibodies Remain a Problem for the Immunoassay Laboratory
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The prevalence of heterophilic antibody interference in a modern immunochemiluminometric assay containing blocking agents was determined using thyrotropin as an illustrative example. Serum samples were obtained from 295 consecutive patients who underwent routine thyroid function testing. The following versions of the thyrotropin assay were used: protocol A (zero blocker), protocol B (routine blocker concentration), and protocol C (extra blocker). Ten patients (prevalence 3.4%) had significant levels of heterophilic antibodies (protocol A value greater than 9 SD from the protocol B value). The observed thyrotropin levels for protocols B and C were the same for all patients, consistent with the reagent blockers in routine assays adequately eliminating heterophilic antibody interference. However, seven more patients (0.03%) in series of 21,000 assessed by routine thyroid function testing had discordant results because of a concentration of heterophilic antibodies so high as to overwhelm the added blocking agents.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Statistical methods for assessing agreement between two methods of clinical measurement
Bland, J. M., & Altman, D. G. (2010) · International Journal of Nursing Studies · doi:10.1016/j.ijnurstu.2009.10.001 · Cited by 5,220
The Use and Misuse of the Sensitive Thyrotropin Assays
NICOLOFF, J. T., & SPENCER, C. A. (1990) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem-71-3-553 · Cited by 197
Cited by
Subclinical Thyroid Disease: Scientific Review and Guidelines for Diagnosis and Management
Surks, M. I., Ortiz, E., Daniels, G. H., Sawin, C. T., Col, N. F., Cobin, R. H., Franklyn, J. A., Hershman, J. M., Burman, K. D., Denke, M. A., et al. (2004) · JAMA · doi:10.1001/jama.291.2.228 · Cited by 1,800
The Thyrotropin Reference Range Should Remain Unchanged
Surks, M. I., Goswami, G., & Daniels, G. H. (2005) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2005-0170 · Cited by 287
Levinson, S. S., & Miller, J. J. (2002) · Clinica Chimica Acta · doi:10.1016/s0009-8981(02)00275-9 · Cited by 236
Stockigt, J. R., & Lim, C.-F. (2009) · Best Practice & Research Clinical Endocrinology & Metabolism · doi:10.1016/j.beem.2009.06.004 · Cited by 79
Abnormal serum free thyroid hormone levels due to heparin administration
Laji, K. (2001) · QJM · doi:10.1093/qjmed/94.9.471 · Cited by 37
Metadata
- Authors
- Ward, G., Mckinnon, L., Badrick, T., & Hickman, P. E.
- Venue
- American Journal of Clinical Pathology
- Publisher
- Oxford University Press (OUP)
- Published
- 1997-10-01
- Volume
- 108
- Issue
- 4
- Pages
- 417-421
- ISSN
- 0002-9173 (ISSN-L)
- 1943-7722
- OpenAlex
- W204465126
- Cited by
- 112
- References
- 2
- FWCI
- 1.72
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.