The DOI matches its Crossref record.
Formalin Fixation for Electron Microscopy: A Re-evaluation
Abstract
Several common formaldehyde fixative solutions using various buffer systems were evaluated for use with both light and electron microscopy. Ultrastructural detail was judged best using formaldehyde buffered with monobasic sodium phosphate and sodium hydroxide, which is easy to prepare and of such low cost that it serves as an excellent routine fixative for all specimens. A parallel series of specimens, half of which were fixed in this solution and half in Millonig’s phosphate buffered paraformaldehyde, demonstrated no obvious variations in ultrastructural preservation due to the 10 to 15% methanol present in formalin. The need for preselection of tissue to be subsequently examined ultrastructurally is unnecessary if this fixative is used routinely in the histopathology laboratory.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Rosa, D. D., Grześkowiak, Ł. M., Ferreira, C. L. L. F., Fonseca, A. C. M., Reis, S. A., Dias, M. M., Siqueira, N. P., Silva, L. L., Neves, C. A., Oliveira, L. L., et al. (2016) · Food & Function · doi:10.1039/c6fo00339g · Cited by 62
Davis, W. L., Jones, R. G., & Hagler, H. K. (1981) · Journal of Histochemistry & Cytochemistry · doi:10.1177/29.5.7252127 · Cited by 34
Metadata
- Authors
- Carson, F. L., Martin, J. H., & Lynn, J. A.
- Venue
- American Journal of Clinical Pathology
- Publisher
- Oxford University Press (OUP)
- Published
- 1973-03-01
- Volume
- 59
- Issue
- 3
- Pages
- 365-373
- ISSN
- 0002-9173 (ISSN-L)
- 1943-7722
- OpenAlex
- W2317198665
- Cited by
- 397
- References
- 0
- FWCI
- 2.92
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Formalin Fixation for Electron Microscopy: A Re-evaluation. https://app.cochat.ai/papers/10.1093/ajcp/59.3.365
- The paper
- Carson, F. L., Martin, J. H., & Lynn, J. A. (1973). Formalin Fixation for Electron Microscopy: A Re-evaluation. American Journal of Clinical Pathology. https://doi.org/10.1093/ajcp/59.3.365
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.