Using Machine Learning-Based Multianalyte Delta Checks to Detect Wrong Blood in Tube Errors
Open accessThe DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
Objectives: An unfortunate reality of laboratory medicine is that blood specimens collected from one patient occasionally get mislabeled with identifiers from a different patient, resulting in so-called “wrong blood in tube” (WBIT) errors and potential patient harm. Here, we sought to develop a machine learning-based, multianalyte delta check algorithm to detect WBIT errors and mitigate patient harm. Methods: We simulated WBIT errors within sets of routine inpatient chemistry test results to develop, train, and evaluate five machine learning-based WBIT detection algorithms. Results: The best-performing WBIT detection algorithm we developed was based on a support vector machine and incorporated changes in test results between consecutive collections across 11 analytes. This algorithm achieved an area under the curve of 0.97 and considerably outperformed traditional single-analyte delta checks. Conclusions: Machine learning-based multianalyte delta checks may offer a practical strategy to identify WBIT errors prior to test reporting and improve patient safety.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The application of ML models demonstrated superior capabilities in preventing WBIT errors, effectively reducing potential harm to patients [28].”
From Machine learning-based clinical decision support using laboratory data (2024) · cites this paper as [28]
In the citing paper
“The SVM model outperformed conventional single-analyte delta checks, exhibiting an impressive AUC of 0.97.”
From Machine learning-based clinical decision support using laboratory data (2024) · cites this paper as [28]
Citations
Cites
R: A Language and Environment for Statistical Computing
R Core Team (2025) · doi:10.32614/r.manuals · Cited by 352,181
Medical error—the third leading cause of death in the US
Makary, M. A., & Daniel, M. (2016) · BMJ · doi:10.1136/bmj.i2139 · Cited by 3,264
Misc Functions of the Department of Statistics, ProbabilityTheory Group (Formerly: E1071), TU Wien
MEYER, D. A., Dimitriadou, E., Hornik, K., Weingessel, A., & Leisch, F. (2015) · Cited by 523
Introduction to Machine Learning
Baştanlar, Y., & Özuysal, M. (2014) · Methods in Molecular Biology · doi:10.1007/978-1-62703-748-8_7 · Cited by 505 · cited 1×
“SVMs have been extensively described in prior literature.(17) We trained support vector machine-based models in R using the e1071 package with default settings.”
MethodLaposata, M., & Dighe, A. (2007) · Clinical Chemical Laboratory Medicine · doi:10.1515/cclm.2007.173 · Cited by 162
An international study of the performance of sample collection from patients
Dzik, S., Murphy, M. F., Andreu, G., Heddle, N. M., Högman, C. F., Kekomäki, R., Murphy, S., Shimizu, M., Smit‐Sibinga, C. T., & the Biomedical Excellence for Safer Transfusion (BEST) Working Party of the International Society for Blood Transfusion (2003) · Vox Sanguinis · doi:10.1046/j.1423-0410.2003.00313.x · Cited by 152 · cited 1×
“6,7 For example, in one setting, Dzik et al 8 found that WBIT errors occurred in approximately one in 165 specimens.”
BackgroundTopaz, M., Seger, D. L., Slight, S. P., Goss, F., Lai, K., Wickner, P. G., Blumenthal, K., Dhopeshwarkar, N., Chang, F., Bates, D. W., et al. (2016) · Journal of the American Medical Informatics Association · doi:10.1093/jamia/ocv143 · Cited by 116
Wrong blood in tube – potential for serious outcomes: can it be prevented?
Bolton‐Maggs, P. H. B., Wood, E. M., & Wiersum‐Osselton, J. C. (2014) · British Journal of Haematology · doi:10.1111/bjh.13137 · Cited by 74 · cited 1×
“6,7 For example, in one setting, Dzik et al 8 found that WBIT errors occurred in approximately one in 165 specimens.”
BackgroundDickerson, J. A., Cole, B., Conta, J. H., Wellner, M., Wallace, S. E., Jack, R. M., Rutledge, J. C., & Astion, M. L. (2013) · Archives of Pathology & Laboratory Medicine · doi:10.5858/arpa.2012-0726-oa · Cited by 63 · cited 1×
“3-5 Likewise, other prean-alytic laboratory testing errors, such as those related to improper specimen collection, transport, or processing, can also lead to erroneous test results and may unfortunately be somewhat common.”
BackgroundThe role of informatics and decision support in utilization management
Baron, J. M., & Dighe, A. S. (2013) · Clinica Chimica Acta · doi:10.1016/j.cca.2013.09.027 · Cited by 61
Self-citation
Research works printed but not linked: 2
- National Center for Health Statistics, 2017, Health, United States, 2016: With Chartbook on Long-Term Trends in Health
- 2012, National Comparative Audit of Blood Transfusion
Cited by
Role of artificial intelligence in patient safety outcomes: systematic literature review
Choudhury, A., & Asan, O. (2020) · JMIR Medical Informatics · doi:10.2196/18599 · Cited by 440
“Another study used inpatient laboratory test reports from Sunquest Laboratory Information System and identified wrong blood in tube errors [80].”
MethodInfluentialArtificial Intelligence and Mapping a New Direction in Laboratory Medicine: A Review
Herman, D. S., Rhoads, D. D., Schulz, W. L., & Durant, T. J. S. (2021) · Clinical Chemistry · doi:10.1093/clinchem/hvab165 · Cited by 81
Rashidi, H. H., Pantanowitz, J., Hanna, M. G., Tafti, A. P., Sanghani, P., Buchinsky, A., Fennell, B. D., Deebajah, M., Wheeler, S., Pearce, T. M., et al. (2025) · Modern Pathology · doi:10.1016/j.modpat.2024.100688 · Cited by 113
Machine learning-based clinical decision support using laboratory data
Çubukçu, H. C., Topcu, D. İ., & Yenice, S. (2024) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2023-1037 · Cited by 66
“Rosenbaum et al. directed their research toward identifying WBIT errors by utilizing logistic regression and support vector machine (SVM) models [28].”
MethodPantanowitz, L., Pearce, T. M., Abukhiran, I. M., Hanna, M. G., Wheeler, S., Soong, T. R., Tafti, A. P., Pantanowitz, J., Lu, M. Y., Mahmood, F., et al. (2024) · Modern Pathology · doi:10.1016/j.modpat.2024.100680 · Cited by 89
Clinlabomics: leveraging clinical laboratory data by data mining strategies
Wen, X., Leng, P., Wang, J., Yang, G., Zu, R., Jia, X., Zhang, K., Mengesha, B. A., Huang, J. H., Wang, D., et al. (2022) · BMC Bioinformatics · doi:10.1186/s12859-022-04926-1 · Cited by 81
“Continuous monitoring of specimen acceptability, collection and transport can result in the prompt identification and correction of problems, leading to improved patient care and a reduction in unnecessary redraws and delays in reporting results [85–88].”
MethodResultInfluentialRise of the Machines: Artificial Intelligence and the Clinical Laboratory
Haymond, S., & McCudden, C. R. (2021) · The Journal of Applied Laboratory Medicine · doi:10.1093/jalm/jfab075 · Cited by 80
Hanna, M. G., Olson, N. H., Zarella, M. D., Dash, R. C., Herrmann, M. D., Furtado, L. V., Stram, M. N., Raciti, P. M., Hassell, L. A., Mays, A., et al. (2023) · Archives of Pathology & Laboratory Medicine · doi:10.5858/arpa.2023-0042-cp · Cited by 58
Recent evolutions of machine learning applications in clinical laboratory medicine
Bruyne, S. D., Speeckaert, M. M., Biesen, W. V., & Delanghe, J. (2020) · Critical Reviews in Clinical Laboratory Sciences · doi:10.1080/10408363.2020.1828811 · Cited by 60
“Rosenbaum and Baron [30] demonstrated that ML-based multianalyte delta checks have the potential to overpower traditional single-analyte delta checks.”
BackgroundMethodInfluentialArtificial intelligence in the clinical laboratory
Hou, H., Zhang, R., & Li, J. (2024) · Clinica Chimica Acta · doi:10.1016/j.cca.2024.119724 · Cited by 65
Deimazar, G., & Sheikhtaheri, A. (2023) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2023.105246 · Cited by 58
Identifying mislabelled samples: Machine learning models exceed human performance
Farrell, C.-J. (2021) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1177/00045632211032991 · Cited by 35
“Preliminary investigations have demonstrated that machine learning (ML) models are superior to delta checks in identifying mislabelled samples.(2,3) The relative performance of different ML algorithms has not been established, however.”
BackgroundYang, H. S., Rhoads, D. D., Sepulveda, J. L., Zang, C., Chadburn, A., & Wang, F. (2022) · Archives of Pathology & Laboratory Medicine · doi:10.5858/arpa.2021-0635-ra · Cited by 42
Ronzio, L., Cabitza, F., Barbaro, A., & Banfi, G. (2021) · Diagnostics · doi:10.3390/diagnostics11020372 · Cited by 36
“Using Machine Learning-Based Multianalyte Delta Checks to Detect Wrong Blood in Tube Errors Rosenbaum and Baron (2018) [26] 2018 LM 20,638 patient collections of 4855 patients 3 features for each of 11 lab tests RC Rch To test whether machine learning-based multianalyte delta checks could outperform traditional single…”
MethodInfluentialAutomating the Detection of IV Fluid Contamination Using Unsupervised Machine Learning
Spies, N. C., Hubler, Z. M. L., Azimi, V., Zhang, R., Jackups, R., Gronowski, A. M., Farnsworth, C. W., & Zaydman, M. A. (2023) · Clinical Chemistry · doi:10.1093/clinchem/hvad207 · Cited by 23
Farrell, C.-J. L., Makuni, C., Keenan, A., Maeder, E., Davies, G., & Giannoutsos, J. (2023) · Clinical Chemistry · doi:10.1093/clinchem/hvad100 · Cited by 24
Lorde, N., Mahapatra, S., & Kalaria, T. (2024) · Diagnostics · doi:10.3390/diagnostics14161808 · Cited by 38
“Rosenbaum and Baron used ML multianalyte delta checks to identify WBIT [39].”
MethodA Machine Learning Approach for the Automated Interpretation of Plasma Amino Acid Profiles
Wilkes, E. H., Emmett, E. C., Beltran, L., Woodward, G., & Carling, R. S. (2020) · Clinical Chemistry · doi:10.1093/clinchem/hvaa134 · Cited by 22
Optimized Delta Check Rules for Detecting Misidentified Specimens in Children
Tan, R. Z., Markus, C., Choy, K. W., Doery, J. C. G., & Loh, T. P. (2019) · American Journal of Clinical Pathology · doi:10.1093/ajcp/aqz201 · Cited by 18
Haroun, A., Al-Ruzzieh, M. A., Hussien, N., Masa’ad, A., Hassoneh, R., Alrub, G. A., & Ayaad, O. A. (2021) · Asian Pacific Journal of Cancer Prevention · doi:10.31557/apjcp.2021.22.4.1247 · Cited by 25
“…barcode system, automated sample labeling, delta checks, and electronic identification system (Al-Ruzzieh et al., 2020; Ning et al., 2016; Rosenbaum and Baron, 2018; Sharikh et al., 2020); redesigning the process; structured quality and administrative rounds (Ayaad, et al., 2019); proper…”
BackgroundMethodArtificial Intelligence Applications in Clinical Chemistry
Bunch, D. R., Durant, T. J. S., & Rudolf, J. W. (2022) · Clinics in Laboratory Medicine · doi:10.1016/j.cll.2022.09.005 · Cited by 21
Impact of delta check time intervals on error detection capability
Tan, R. Z., Markus, C., & Loh, T. P. (2019) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2019-1004 · Cited by 17
Choucair, I., Lee, E. S., Vera, M. A., Drongmebaro, C., El-Khoury, J. M., & Durant, T. J. S. (2022) · Clinica Chimica Acta · doi:10.1016/j.cca.2022.10.011 · Cited by 15
Machine Learning and Other Emerging Decision Support Tools
Baron, J. M., Kurant, D. E., & Dighe, A. S. (2019) · Clinics in Laboratory Medicine · doi:10.1016/j.cll.2019.01.010 · Cited by 14
Self-citationSeok, H. S., Choi, Y., Yu, S., Shin, K., Kim, S., & Shin, H. (2023) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2023-1185 · Cited by 15
Church, D. L., & Naugler, C. T. (2020) · Critical Reviews in Clinical Laboratory Sciences · doi:10.1080/10408363.2020.1720591 · Cited by 19
Decision support or autonomous artificial intelligence? The case of wrong blood in tube errors
Farrell, C.-J. L. (2022) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2021-0873 · Cited by 12
Farrell, C.-J. L., & Giannoutsos, J. (2022) · International Journal of Laboratory Hematology · doi:10.1111/ijlh.13820 · Cited by 14
Relationship between biological variation and delta check rules performance
Tan, R. Z., Markus, C., & Loh, T. P. (2020) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2020.03.017 · Cited by 12
Benirschke, R. C., & Gniadek, T. J. (2020) · American Journal of Clinical Pathology · doi:10.1093/ajcp/aqaa039 · Cited by 13
Baron, J. M., Paranjape, K., Love, T. M., Sharma, V., Heaney, D. L., & Prime, M. S. (2020) · Journal of the American Medical Informatics Association · doi:10.1093/jamia/ocaa254 · Cited by 15
Self-citationData-Driven Anomaly Detection in Laboratory Medicine: Past, Present, and Future
Spies, N. C., Farnsworth, C. W., & Jackups, R. (2022) · The Journal of Applied Laboratory Medicine · doi:10.1093/jalm/jfac114 · Cited by 16
Applications of machine learning in the chemical pathology laboratory
Punchoo, R., Bhoora, S., & Pillay, N. (2021) · Journal of Clinical Pathology · doi:10.1136/jclinpath-2021-207393 · Cited by 11
“24 Using ML-based multianalyte delta checks, Rosenbaum and Baron 25 investigated the detection of ‘wrong blood in tube’ (WBIT) specimens resulting from incorrect patient identifiers being attached to specimen tubes due to patient misidentification or specimen mislabelling.”
MethodNational survey on delta checks in clinical laboratories in China
He, S., Kang, F., Wang, W., Chen, B., & Wang, Z. (2020) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2019-1131 · Cited by 10
“More complicated multianalyte delta checks [7, 8], which use interrelated analytes for the delta check calculations, have been developed in recent years.”
BackgroundCardozo, G., Tirloni, S. F., Moro, A. R. P., & Marques, J. L. B. (2022) · JMIR Bioinformatics and Biotechnology · doi:10.2196/40473 · Cited by 15
“Similarly, Baron et al [16] used an algorithm to generate a decision tree capable of identifying tests with possible problems arising from the preanalytical process during the execution of laboratory tests.”
MethodCarmack, H. J., Lazenby, B. S., Wilson, K., Bakkum-Gamez, J. N., & Carranza, L. (2024) · American Journal of Clinical Pathology · doi:10.1093/ajcp/aqae055 · Cited by 9
GPT-4 Underperforms Experts in Detecting IV Fluid Contamination
Spies, N. C., Hubler, Z. M. L., Roper, S. M., Omosule, C. L., Senter-Zapata, M. J., Roemmich, B., Brown, H. M., Gimple, R. C., & Farnsworth, C. W. (2023) · The Journal of Applied Laboratory Medicine · doi:10.1093/jalm/jfad058 · Cited by 9
Spies, N. C., Militello, L., Farnsworth, C. W., El-Khoury, J. M., Durant, T. J. S., & Zaydman, M. A. (2024) · Clinical Chemistry · doi:10.1093/clinchem/hvae168 · Cited by 8
Practical delta check limits for tumour markers in different clinical settings
Yu, S., Shin, K., Shin, S., Lee, H., Yoo, S. J., Jun, K. R., Shin, H., & Kim, S. (2023) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2022-1098 · Cited by 9
Machine learning-based error detection in the clinical laboratory: a critical review
Lin, Y., Mensah, I. K., Doering, M. M., Shean, R. C., & Spies, N. C. (2025) · Critical Reviews in Clinical Laboratory Sciences · doi:10.1080/10408363.2025.2512468 · Cited by 6
Artificial Intelligence in the Clinical Laboratory
Baron, J. M. (2022) · Clinics in Laboratory Medicine · doi:10.1016/j.cll.2022.09.002 · Cited by 7
Self-citationLoh, T. P., Tan, R. Z., Sethi, S. K., Lim, C. Y., & Markus, C. (2023) · Advances in clinical chemistry · doi:10.1016/bs.acc.2023.03.005 · Cited by 7
Graham, B. V., Master, S. R., Obstfeld, A. E., & Wilson, R. B. (2025) · Clinical Chemistry · doi:10.1093/clinchem/hvae210 · Cited by 7
The role of AI in pre-analytical phase – use cases
Çubukçu, H. C. (2025) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2025-1220 · Cited by 6
Choudhury, A., Saremi, M. L., & Urena, E. (2022) · Advances in medical technologies and clinical practice book series · doi:10.4018/978-1-6684-5092-5.ch005 · Cited by 8
Kim, M., Park, C., Namgoong, S., Kim, S.-I., Cho, Y., & Jang, S. (2023) · Annals of Laboratory Medicine · doi:10.3343/alm.2023.43.5.418 · Cited by 5
“Some recent studies have used machine learning for delta check [14, 15]; however, few studies on hematologic tests have been published.”
Implementing Delta Checks for Laboratory Investigations Module of Hospital Management Systems
Kumar, A., Soman, S., & Ranjan, P. (2020) · Lecture notes in electrical engineering · doi:10.1007/978-981-15-7804-5_34 · Cited by 2
Sürmeli, B. G., Staritzbichler, R., Ringel, C., Al-Dakkak, S., Dörksen, H., & Kaiser, T. (2025) · Journal of Personalized Medicine · doi:10.3390/jpm15090404 · Cited by 1
“Other widely used machine learning algorithms, including Neural Networks and Support Vector Machines (SVMs), have also been successfully applied in related work [14,15,20].”
InfluentialData analytics for error detection in clinical laboratories
Chan, C. W. (2025) · Critical Reviews in Clinical Laboratory Sciences · doi:10.1080/10408363.2025.2555261 · Cited by 2
Urgent samples in clinical laboratories: stochastic batching to minimize patient turnaround time
Novák, A., Gnatowski, A., & Šůcha, P. (2026) · Health Care Management Science · doi:10.1007/s10729-026-09756-8 · Cited by 1
“From a laboratory management point of view, this is an important step in eliminating manual and routine work (which is often a source of mistakes, such as incorrect blood in tube errors [20]).”
Machine learning to optimize cerebrospinal fluid dilution for analysis of MRZH reaction
Turčić, A., Štajduhar, A., Vogrinc, Ž., Zaninović, L., & Rogić, D. (2023) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2023-1013 · Cited by 2
Raymond, C., Dell’Osso, L., Guerra, D., Hernandez, J., Rendon, L., Fuller, D., Tezanos, A. G. V., Garcia, J., McCaffrey, P., & Zahner, C. J. (2024) · Journal of Clinical Pathology · doi:10.1136/jcp-2024-209544 · Cited by 1
Blood urea nitrogen/creatinine change ratio as a delta check method for dialysis specimens.
Jeon, B. R. (2020) · PubMed Central
Machine learning and big data in pediatric laboratory medicine
Haymond, S., Julian, R. K., Gill, E. L., & Master, S. R. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-817962-8.00018-4
Cardozo, G., Tirloni, S. F., Moro, A. R. P., & Marques, J. L. B. (2022) · doi:10.2196/preprints.40473
Shater, K., Gerhards, C., Evliyaoğlu, O., Nittka, S., & Fischer, A. (2026) · AI in Medicine · doi:10.3390/aimed1020013
“Related work has used machine learning to detect specimen misidentification through multi-analyte delta checks [9,10], and broader perspectives have argued that artificial intelligence in laboratory medicine is most valuable as decision support rather than as autonomous diagnosis [11,12].”
Yang, J., Wang, L., Hu, G., & Tacker, D. H. (2026) · Laboratory Medicine · doi:10.1093/labmed/lmag034
Spies, N. C., & Farnsworth, C. W. (2026) · The Journal of Applied Laboratory Medicine · doi:10.1093/jalm/jfag128
Metadata
- Authors
- Rosenbaum, M. W., & Baron, J. M.
- Affiliations
- Harvard University (US)
- Corresponding author
- Baron, Jason M
- Venue
- American Journal of Clinical Pathology
- Publisher
- Oxford University Press (OUP)
- Published
- 2018-08-30
- Volume
- 150
- Issue
- 6
- Pages
- 555-566
- ISSN
- 0002-9173 (ISSN-L)
- 1943-7722
- OpenAlex
- W2889512148
- Cited by
- 58
- References
- 21
- Citations by year
- 2026: 4 · 2025: 6 · 2024: 6 · 2023: 11 · 2022: 10 · 2021: 8 · 2020: 10 · 2019: 3
- FWCI
- 3.60
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- academic.oup.com/journals/pages/open_access/funder_policies/chorus/standard_publication_model (vor)
- Locations
- American Journal of Clinical Pathology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Patient Safety and Medication Errors
- Health Sciences › Health Professions › Health Information Management › Artificial Intelligence in Healthcare
- Keywords
- patient identification errors, machine learning, support vector machine, patient safety, error detection algorithm
- MeSH terms
- Machine Learning, Algorithms, Blood Specimen Collection, Humans, Medical Errors, Patient Safety
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.