Determination of Clinical Accuracy and Nocturnal Blood Pressure Pattern by New Portable Device for Monitoring Indirect Ambulatory Blood Pressure
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The accuracy and clinical application of a new portable device for measuring ambulatory blood pressure (BP) (ABPM 630, Nippon Colin, Nagoya, Japan) were assessed. The device uses a conventional arm cuff inflated by CO2 gas from a compact cartridge and is based on a cuff-oscillometric as well as a Korotkoff sound (microphone) technique. Blood pressure values obtained by ABPM 630 were compared with those measured by the auscultatory method. With the microphone method the mean differences from the auscultatory method were -0.28 +/- 6.15 mm Hg (mean +/- SD) for SBP and 0.96 +/- 6.28 mm Hg for DBP (n = 256), while for the cuff-oscillometric method the mean differences were -1.77 +/- 6.07 mm Hg for SBP and 3.06 +/- 6.87 mm Hg for DBP (n = 297). There was a highly significant correlation between BP values measured by the auscultatory method and ABPM 630. In 40 untreated subjects, 24 h BP was monitored simultaneously with the ABPM 630 and with a finger volume-oscillometric device (UBP-100, UEDA, Tokyo, Japan). The daytime average of SBP with the former (126 +/- 11.6 mm Hg) was almost the same as that with the latter (123 +/- 16.0 mm Hg), while the nighttime average in the former (117 +/- 9.7 mm Hg) was significantly higher than that in the latter (108 +/- 14.1 mm Hg, P less than .01). Only 4 out of 40 subjects experienced no sleep disturbance from the arm-cuff inflation. Five of the 40 subjects complained that their sleep was frequently interrupted by the arm-cuff inflation.(ABSTRACT TRUNCATED AT 250 WORDS)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Yamakoshi, K., Shimazu, H., Shibata, M., & Kamiya, A. (1982) · Medical & Biological Engineering & Computing · doi:10.1007/bf02442797 · Cited by 129
Cited by
The Japanese Society of Hypertension Guidelines for the Management of Hypertension (JSH 2019)
Umemura, S., Arima, H., Arima, S., Asayama, K., Dohi, Y., Hirooka, Y., Horio, T., Hoshide, S., Ikeda, S., Ishimitsu, T., et al. (2019) · Hypertension Research · doi:10.1038/s41440-019-0284-9 · Cited by 1,880
Ohkubo, T., Hozawa, A., Yamaguchi, J., Kikuya, M., Ohmori, K., Michimata, M., Matsubara, M., Hashimoto, J., Hoshi, H., Araki, T., et al. (2002) · Journal of Hypertension · doi:10.1097/00004872-200211000-00017 · Cited by 1,053
Self-citationPrognostic accuracy of day versus night ambulatory blood pressure: a cohort study
Boggia, J., Li, Y., Thijs, L., Hansen, T. W., Kikuya, M., Björklund-Bodegård, K., Richart, T., Ohkubo, T., Kuznetsova, T., Torp-Pedersen, C., et al. (2007) · The Lancet · doi:10.1016/s0140-6736(07)61538-4 · Cited by 887
Self-citationPrognostic Significance of Blood Pressure and Heart Rate Variabilities: The Ohasama Study
Kikuya, M., Hozawa, A., Ohokubo, T., Tsuji, I., Michimata, M., Matsubara, M., Ota, M., Nagai, K., Araki, T., Satoh, H., et al. (2000) · Hypertension · doi:10.1161/01.hyp.36.5.901 · Cited by 609
Self-citationOhkubo, T., Kikuya, M., Metoki, H., Asayama, K., Obara, T., Hashimoto, J., Totsune, K., Hoshi, H., Satoh, H., & Imai, Y. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.03.070 · Cited by 575
Self-citation
Metadata
- Authors
- Imai, Y., Abe, K., Sasaki, S., Mxnami, N., Munakata, M., Sekino, H., Nihei, M., & Yoshinaga, K.
- Venue
- American Journal of Hypertension
- Publisher
- Oxford University Press (OUP)
- Published
- 1990-04-01
- Volume
- 3
- Issue
- 4
- Pages
- 293-301
- ISSN
- 0895-7061 (ISSN-L)
- 1941-7225
- OpenAlex
- W2330581560
- Cited by
- 78
- References
- 1
- FWCI
- 2.94
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.