CoChat

The Accuracy and Performance of the A&D TM 2421, a New Ambulatory Blood Pressure Monitoring Device Based on the Cuff-Oscillometric Method and the Korotkoff Sound Technique

Imai, Yutaka, Sasaki, Shuichi, Minami, Naoyoshi, Munakata, Masanori, Hashimoto, Junichiro, Sakuma, Hiromichi, Sakuma, Mariko, Watanabe, Noriko, Imai, Keiko, Sekino, Hiroshi, Abe, Keishi · 1992 · American Journal of Hypertension
Cited by 130

The DOI matches its Crossref record.

Abstract

The accuracy and performance of the A&D TM 2421, a new ambulatory blood pressure (BP) monitoring device using both the cuff-oscillometric method (O) and the Korotkoffsound method (K) were evaluated. The device was tested for accuracy under static and dynamic conditions by simultaneous comparison with two observers using a standard mercury column sphygmomanometer (standard method) and by the objective recording method (ORM). The performance of the device was also evaluated under ordinary ambulatory conditions. The mean differences in BP of standard method from K-method were −1.2 ± 4.7 mm Hg systole and 1.3 ± 4.7 mm Hg diastole (n = 323, mean ± SD) and those of standard method from Omethod were −0.4 ± 5.3 mm Hg systole and 1.4 ± 5.1 mm Hg diastole (n = 323). The agreement between each of the two methods of the device and the standard method was within 10 mm Hg for more than 90% of both systolic and diastolic readings. During bicycle exercise, the mean differences in BP of standard method from K-method were ࢤ3 . 4 ± 4.8 mm Hg systole and 1.8 ± 5.2 mm Hg diastole (n = 71) and those of standard method from O-method were −1.1 ± 7.3 mm Hg systole and 1.7 ± 7.8 mm Hg diastole (n = 67). There was a greater scatter in the individual comparisons of the device and the standard method during exercise, especially in diastolic BP. The relation between the device and ORM was almost similar to that between the device and the standard method. In 130 subjects the mean ambulatory monitoring period with the TM 2421 was 23.7 ± 0.6 h. In the K-method the error codes (failed recordings) were given as 13.0% of measurements, while in the O-method it was 4.3%. When the data obtained by the K-method were added to the failures in the O-method, only 1% of expected recordings had failed. The results suggest that the A&D TM 2421 unit is valid for clinical and research study. Am J Hypertens 1992;5:719-726

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/ajh/5.10.719

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Imai, Y., Sasaki, S., Minami, N., Munakata, M., Hashimoto, J., Sakuma, H., Sakuma, M., Watanabe, N., Imai, K., Sekino, H., & Abe, K.
Venue
American Journal of Hypertension
Published
1992-10
Volume
5
Issue
10
Pages
719-726
ISSN
  • 0895-7061 (ISSN-L)
  • 1941-7225
OpenAlex
W2340316228
Cited by
130
References
0
FWCI
2.71
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.