White Coat Hypertension Diagnosed by 24-h Ambulatory Monitoring
The DOI matches its Crossref record.
Abstract
The study was conducted to estimate the frequency of white coat hypertension, ie, hypertension when in contact with the doctor only, in patients with newly diagnosed hypertension. We studied 159 consecutive patients (median age 47 years, 86 women) referred from primary health care to a hypertension clinic. For all patients, their general practitioner had decided to treat the hypertension pharmacologically, but the treatment had not yet begun. The blood pressure measurements reported from the referring doctors were 164.1 +/- 18.1/104.3 +/- 7.1 mm Hg (mean +/- SD). Measured at the hypertension clinic with random zero sphygmomanometer the pressures were 156.8 +/- 22.5/99.8 +/- 11.7 mm Hg. The indirectly measured day-time ambulatory blood pressures were 145.2 +/- 18.1/95.9 +/- 11.5 mm Hg. When a cut-off level of 90 mm Hg diastolic was applied, all patients were considered hypertensive by the referring doctors' measurements; the random zero office measurements regarded 18.3% of the patients as normotensive. The ambulatory measurements regarded a further 24.8% as normotensive (white coat hypertensive), whereas five patients considered normotensive by office measurements were hypertensive when evaluated by ambulatory monitoring (reverse white coat phenomenon). The difference between systolic office measurements and the daytime ambulatory blood pressures was significantly larger for female patients; age was positively correlated and weight negatively correlated to this difference. No significant difference was found for the diastolic measurements. It is concluded that white coat hypertension is present in approximately a quarter of the patients with newly diagnosed hypertension. By implementing ambulatory monitoring in clinical practice some of the overdiagnosing will possibly be avoided, but further studies on the subject are needed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Recommendations for the use of home (self) and ambulatory blood pressure monitoring
Pickering, T. (1996) · American Journal of Hypertension · doi:10.1016/0895-7061(95)00341-x · Cited by 472
24-h ambulatory blood pressure in 352 normal Danish subjects, related to age and gender*
Wiinberg, N., Høegholm, A., Christensen, H. R., Bang, L. E., Mikkelsen, K. L., Nielsen, P. E., Svendsen, T. L., Kampmann, J. P., Madsen, N. H., & Bentzon, M. W. (1995) · American Journal of Hypertension · doi:10.1016/0895-7061(95)00216-2 · Cited by 412
Self-citationVerdecchia, P., Schillaci, G., Boldrini, F., Zampi, I., & Porcellati, C. (1992) · Hypertension · doi:10.1161/01.hyp.20.4.555 · Cited by 185
Reference Values for Self-recorded Blood Pressure: A Meta-analysis of Summary Data
Thijs, L., Staessen, J. A., Celis, H., de Gaudemaris, R., Imai, Y., Julius, S., & Fagard, R. (1998) · Archives of Internal Medicine · doi:10.1001/archinte.158.5.481 · Cited by 143
White coat hypertension.: No harm for the heart.
Gosse, P., Promax, H., Durandet, P., & Clementy, J. (1993) · Hypertension · doi:10.1161/01.hyp.22.5.766 · Cited by 125
Metadata
- Authors
- Høegholm, A., Kristensen, K. S., Madsen, N. H., & Svendsen, T. L.
- Venue
- American Journal of Hypertension
- Publisher
- Oxford University Press (OUP)
- Published
- 1992-01
- Volume
- 5
- Issue
- 2
- Pages
- 64-70
- ISSN
- 0895-7061 (ISSN-L)
- 1941-7225
- OpenAlex
- W1903963968
- Cited by
- 108
- References
- 0
- FWCI
- 7.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: White Coat Hypertension Diagnosed by 24-h Ambulatory Monitoring. https://app.cochat.ai/papers/10.1093/ajh/5.2.64
- The paper
- Høegholm, A., Kristensen, K. S., Madsen, N. H., & Svendsen, T. L. (1992). White Coat Hypertension Diagnosed by 24-h Ambulatory Monitoring. American Journal of Hypertension. https://doi.org/10.1093/ajh/5.2.64
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.