A NEW PERSONAL SAMPLER FOR AIRBORNE TOTAL DUST IN WORKPLACES
Abstract
This paper describes the development and testing of a new personal dust sampler for airborne ‘total’ dust in workplaces. The cornerstone of the work involves the use of a full-size tailor's mannequin to represent the human worker both for the mounting of the personal samplers and as the reference against which the personal samplers are tested. This resultant evaluation is therefore consistent with the concept of inspirability which is now gaining acceptance as a biologically relevant criterion for ‘total’ dust. In the initial part of the work it was found that the performances of a number of commercially available personal samplers of the type currently recommended for the assessment of ‘total’ dust in workplaces are not only substantially different from one another but also substantially different from inspirability. A study of the parameters governing performance was then carried out, leading to the development of a new sampler comprising a 15 mm dia. circular entry through which air is drawn at 2 1. min −1 . It was shown that this sampler when worn on the lapel collects the inspirable fraction of airborne dust satisfactorily over a representative range of particle aerodynamic sizes and wind speeds. The design incorporates a dust-collecting cassette which has the advantage of minimizing errors due both to particle blow-off from external surface and to internal wall losses.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Elemental Carbon-Based Method for Monitoring Occupational Exposures to Particulate Diesel Exhaust
Birch, M. E., & Cary, R. A. (1996) · Aerosol Science and Technology · doi:10.1080/02786829608965393 · Cited by 1,783
Concentrations and Emissions of Airborne Dust in Livestock Buildings in Northern Europe
Takai, H., Pedersen, S., Johnsen, J. O., Metz, J. H. M., Groot Koerkamp, P. W. G., Uenk, G. H., Phillips, V. R., Holden, M. R., Sneath, R. W., Short, J. L., et al. (1998) · Journal of Agricultural Engineering Research · doi:10.1006/jaer.1997.0280 · Cited by 342
Birch, M. E., & Cary, R. A. (1996) · The Analyst · doi:10.1039/an9962101183 · Cited by 275
Assessing exposure to airborne nanomaterials: Current abilities and future requirements
Maynard, A. D., & Aitken, R. J. (2007) · Nanotoxicology · doi:10.1080/17435390701314720 · Cited by 261
The assessment of bioaerosols: A critical review
Griffiths, W. D., & DeCosemo, G. A. L. (1994) · Journal of Aerosol Science · doi:10.1016/0021-8502(94)90218-6 · Cited by 215
Metadata
- Authors
- MARK, D., & VINCENT, J. H.
- Venue
- Annals of Occupational Hygiene
- Publisher
- Oxford University Press (OUP)
- Published
- 1986
- Volume
- 30
- Issue
- 1
- Pages
- 89-102
- ISSN
- 0003-4878 (ISSN-L)
- 1475-3162
- OpenAlex
- W1991804971
- Cited by
- 281
- References
- 0
- FWCI
- 15.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A NEW PERSONAL SAMPLER FOR AIRBORNE TOTAL DUST IN WORKPLACES. https://app.cochat.ai/papers/10.1093/annhyg/30.1.89
- The paper
- MARK, D., & VINCENT, J. H. (1986). A NEW PERSONAL SAMPLER FOR AIRBORNE TOTAL DUST IN WORKPLACES. Annals of Occupational Hygiene. https://doi.org/10.1093/annhyg/30.1.89
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.