Effectiveness of Three Decontamination Treatments against Influenza Virus Applied to Filtering Facepiece Respirators
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Filtering facepiece respirators (FFRs) are recommended for use as precautions against airborne pathogenic microorganisms; however, during pandemics demand for FFRs may far exceed availability. Reuse of FFRs following decontamination has been proposed but few reported studies have addressed the feasibility. Concerns regarding biocidal efficacy, respirator performance post decontamination, decontamination cost, and user safety have impeded adoption of reuse measures. This study examined the effectiveness of three energetic decontamination methods [ultraviolet germicidal irradiation (UVGI), microwave-generated steam, and moist heat] on two National Institute for Occupational Safety and Health-certified N95 FFRs (3M models 1860s and 1870) contaminated with H5N1. An aerosol settling chamber was used to apply virus-laden droplets to FFRs in a method designed to simulate respiratory deposition of droplets onto surfaces. When FFRs were examined post decontamination by viral culture, all three decontamination methods were effective, reducing virus load by > 4 log median tissue culture infective dose. Analysis of treated FFRs using a quantitative molecular amplification assay (quantitative real-time polymerase chain reaction) indicated that UVGI decontamination resulted in lower levels of detectable viral RNA than the other two methods. Filter performance was evaluated before and after decontamination using a 1% NaCl aerosol. As all FFRs displayed <5% penetration by 300-nm particles, no profound reduction in filtration performance was caused in the FFRs tested by exposure to virus and subsequent decontamination by the methods used. These findings indicate that, when properly implemented, these methods effectively decontaminate H5N1 on the two FFR models tested and do not drastically affect their filtering function; however, other considerations may influence decisions to reuse FFRs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lore, M. B., Sambol, A. R., Japuntich, D. A., Franklin, L. M., & Hinrichs, S. H. (2011) · Journal of Nanoparticle Research · doi:10.1007/s11051-010-9909-2 · Cited by 17
Self-citation
Cited by
Managing ICU surge during the COVID-19 crisis: Rapid guidelines.
Aziz, S., Arabi, Y. M., Alhazzani, W., Evans, L., Citerio, G., Fischkoff, K., Salluh, J., Meyfroidt, G., Alshamsi, F., Oczkowski, S., et al. (2020) · Intensive Care Medicine · doi:10.1007/s00134-020-06092-5 · Cited by 380
Rubio-Romero, J. C., Pardo-Ferreira, M. D. C., Torrecilla-García, J. A., & Calero-Castro, S. (2020) · Safety Science · doi:10.1016/j.ssci.2020.104830 · Cited by 281
Lindsley, W. G., Martin, S. B., Thewlis, R. E., Sarkisian, K., Nwoko, J. O., Mead, K. R., & Noti, J. D. (2015) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2015.1018518 · Cited by 240
“8 J/cm2 dose was sufficient to reduce the amount of viable influenza virus by a factor of >104 (>4-log reduction).(6,8) This suggests that, for influenza virus, dozens of UVGI disinfection cycles could be performed on respirators without the UVGI affecting their performance.”
BackgroundMethodIppolito, M., Vitale, F., Accurso, G., Iozzo, P., Gregoretti, C., Giarratano, A., & Cortegiani, A. (2020) · Pulmonology · doi:10.1016/j.pulmoe.2020.04.009 · Cited by 181
Metadata
- Venue
- The Annals of Occupational Hygiene
- Publisher
- Oxford University Press (OUP)
- Published
- 2011-08-22
- Volume
- 56
- Issue
- 1
- Pages
- 92-101
- ISSN
- 0003-4878 (ISSN-L)
- 1475-3162
- OpenAlex
- W2168060225
- Cited by
- 176
- References
- 1
- FWCI
- 1.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effectiveness of Three Decontamination Treatments against Influenza Virus Applied to Filtering Facepiece Respirators. https://app.cochat.ai/papers/10.1093/annhyg/mer054
- The paper
- Effectiveness of Three Decontamination Treatments against Influenza Virus Applied to Filtering Facepiece Respirators. (2011). The Annals of Occupational Hygiene. https://doi.org/10.1093/annhyg/mer054
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.