CoChat

Evaluating de novo sequencing in proteomics: already an accurate alternative to database-driven peptide identification?

Muth, Thilo, Renard, Bernhard Y · 2018 · Briefings in Bioinformatics
Cited by 119

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

While peptide identifications in mass spectrometry (MS)-based shotgun proteomics are mostly obtained using database search methods, high-resolution spectrum data from modern MS instruments nowadays offer the prospect of improving the performance of computational de novo peptide sequencing. The major benefit of de novo sequencing is that it does not require a reference database to deduce full-length or partial tag-based peptide sequences directly from experimental tandem mass spectrometry spectra. Although various algorithms have been developed for automated de novo sequencing, the prediction accuracy of proposed solutions has been rarely evaluated in independent benchmarking studies. The main objective of this work is to provide a detailed evaluation on the performance of de novo sequencing algorithms on high-resolution data. For this purpose, we processed four experimental data sets acquired from different instrument types from collision-induced dissociation and higher energy collisional dissociation (HCD) fragmentation mode using the software packages Novor, PEAKS and PepNovo. Moreover, the accuracy of these algorithms is also tested on ground truth data based on simulated spectra generated from peak intensity prediction software. We found that Novor shows the overall best performance compared with PEAKS and PepNovo with respect to the accuracy of correct full peptide, tag-based and single-residue predictions. In addition, the same tool outpaced the commercial competitor PEAKS in terms of running time speedup by factors of around 12-17. Despite around 35% prediction accuracy for complete peptide sequences on HCD data sets, taken as a whole, the evaluated algorithms perform moderately on experimental data but show a significantly better performance on simulated data (up to 84% accuracy). Further, we describe the most frequently occurring de novo sequencing errors and evaluate the influence of missing fragment ion peaks and spectral noise on the accuracy. Finally, we discuss the potential of de novo sequencing for now becoming more widely used in the field.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/bib/bbx033

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

Metadata

Authors
Muth, T., & Renard, B. Y.
Venue
Briefings in Bioinformatics
Published
2017-03-21
Volume
19
Issue
5
Pages
954-970
ISSN
  • 1467-5463 (ISSN-L)
  • 1477-4054
OpenAlex
W2603081759
Cited by
119
References
6
FWCI
3.97
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.