DeconMSn: a software tool for accurate parent ion monoisotopic mass determination for tandem mass spectra
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Summary: DeconMSn accurately determines the monoisotopic mass and charge state of parent ions from high-resolution tandem mass spectrometry data, offering significant improvement for LTQ_FT and LTQ_Orbitrap instruments over the commercially delivered Thermo Fisher Scientific's extract_msn tool. Optimal parent ion mass tolerance values can be determined using accurate mass information, thus improving peptide identifications for high-mass measurement accuracy experiments. For low-resolution data from LCQ and LTQ instruments, DeconMSn incorporates a support-vector-machine-based charge detection algorithm that identifies the most likely charge of a parent species through peak characteristics of its fragmentation pattern. Availability: http://ncrr.pnl.gov/software/ or http://www.proteomicsresource.org/ Contact: rds@pnl.gov Supplementary information: PowerPoint presentation/Poster on http://ncrr.pnl.gov/software/.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Senko, M. W., Beu, S. C., & McLaffertycor, F. W. (1995) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(95)00017-8 · Cited by 451 · cited 1×
“This step is accomplished by first calculating the charge using autocorrelationbased peak fitting methods (Senko et al., 1995), following which the monoisotopic mass is calculated by overlapping a calculated theoretical profile (Senko et al., 1995b; Rockwood et al., 1995) with the observed profile.”
Method
Cited by
LipidBlast in silico tandem mass spectrometry database for lipid identification
Kind, T., Liu, K.-H., Lee, D. Y., DeFelice, B., Meissen, J. K., & Fiehn, O. (2013) · Nature Methods · doi:10.1038/nmeth.2551 · Cited by 981
A guided tour of the Trans‐Proteomic Pipeline
Deutsch, E. W., Mendoza, L., Shteynberg, D., Farrah, T., Lam, H., Tasman, N., Sun, Z., Nilsson, E., Pratt, B., Prazen, B., et al. (2010) · PROTEOMICS · doi:10.1002/pmic.200900375 · Cited by 745
Activated ClpP kills persisters and eradicates a chronic biofilm infection
Conlon, B. P., Nakayasu, E. S., Fleck, L. E., LaFleur, M. D., Isabella, V. M., Coleman, K., Leonard, S. N., Smith, R. D., Adkins, J. N., & Lewis, K. (2013) · Nature · doi:10.1038/nature12790 · Cited by 672
Self-citationNesvizhskii, A. I. (2010) · Journal of Proteomics · doi:10.1016/j.jprot.2010.08.009 · Cited by 536
Orbitrap mass spectrometry: Instrumentation, ion motion and applications
Perry, R. H., Cooks, R. G., & Noll, R. J. (2008) · Mass Spectrometry Reviews · doi:10.1002/mas.20186 · Cited by 514
Metadata
- Authors
- Mayampurath, A. M., Jaitly, N., Purvine, S. O., Monroe, M. E., Auberry, K. J., Adkins, J. N., & Smith, R. D.
- Venue
- Bioinformatics
- Publisher
- Oxford University Press (OUP)
- Published
- 2008-02-26
- Volume
- 24
- Issue
- 7
- Pages
- 1021-1023
- ISSN
- 1367-4803 (ISSN-L)
- 1367-4811
- OpenAlex
- W2095826175
- Cited by
- 142
- References
- 1
- FWCI
- 5.16
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: DeconMSn: a software tool for accurate parent ion monoisotopic mass determination for tandem mass spectra. https://app.cochat.ai/papers/10.1093/bioinformatics/btn063
- The paper
- Mayampurath, A. M., Jaitly, N., Purvine, S. O., Monroe, M. E., Auberry, K. J., Adkins, J. N., & Smith, R. D. (2008). DeconMSn: a software tool for accurate parent ion monoisotopic mass determination for tandem mass spectra. Bioinformatics. https://doi.org/10.1093/bioinformatics/btn063
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.