Early immunologic correlates of HIV protection can be identified from computational analysis of complex multivariate T-cell flow cytometry assays
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Motivation: Polychromatic flow cytometry (PFC), has enormous power as a tool to dissect complex immune responses (such as those observed in HIV disease) at a single cell level. However, analysis tools are severely lacking. Although high-throughput systems allow rapid data collection from large cohorts, manual data analysis can take months. Moreover, identification of cell populations can be subjective and analysts rarely examine the entirety of the multidimensional dataset (focusing instead on a limited number of subsets, the biology of which has usually already been well-described). Thus, the value of PFC as a discovery tool is largely wasted. Results: To address this problem, we developed a computational approach that automatically reveals all possible cell subsets. From tens of thousands of subsets, those that correlate strongly with clinical outcome are selected and grouped. Within each group, markers that have minimal relevance to the biological outcome are removed, thereby distilling the complex dataset into the simplest, most clinically relevant subsets. This allows complex information from PFC studies to be translated into clinical or resource-poor settings, where multiparametric analysis is less feasible. We demonstrate the utility of this approach in a large (n=466), retrospective, 14-parameter PFC study of early HIV infection, where we identify three T-cell subsets that strongly predict progression to AIDS (only one of which was identified by an initial manual analysis). Availability: The ‘flowType: Phenotyping Multivariate PFC Assays’ package is available through Bioconductor. Additional documentation and examples are available at: www.terryfoxlab.ca/flowsite/flowType/ Supplementary information: Supplementary data are available at Bioinformatics online. Contact: rbrinkman@bccrc.ca
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bendall, S. C., Simonds, E. F., Qiu, P., Amir, E.-A. D., Krutzik, P. O., Finck, R., Bruggner, R. V., Melamed, R., Trejo, A., Ornatsky, O. I., et al. (2011) · Science · doi:10.1126/science.1198704 · Cited by 2,279
Isolation of Single Human Hematopoietic Stem Cells Capable of Long-Term Multilineage Engraftment
Notta, F., Doulatov, S., Laurenti, E., Poeppl, A., Jurisica, I., & Dick, J. E. (2011) · Science · doi:10.1126/science.1201219 · Cited by 919 · cited 1×
“, 2011), stem cell research (Notta et al., 2011), and cancer (Zimmerlin et al.”
BackgroundHow does multiple testing correction work?
Noble, W. S. (2009) · Nature Biotechnology · doi:10.1038/nbt1209-1135 · Cited by 772
Bard, J., Rhee, S. Y., & Ashburner, M. (2005) · Genome biology · doi:10.1186/gb-2005-6-2-r21 · Cited by 416
A primer on learning in Bayesian networks for computational biology
Needham, C. J., Bradford, J. R., Bulpitt, A. J., & Westhead, D. R. (2007) · PLoS Computational Biology · doi:10.1371/journal.pcbi.0030129 · Cited by 311 · cited 2×
“In future, graph theory (Needham et al., 2007) or graphical modeling tools could be developed both to visualize connections between the cell populations that affect clinical outcome, and to find globally optimized marker sets defining them.”
MethodA model for harmonizing flow cytometry in clinical trials
the FOCIS Human Immunophenotyping Consortium, Maecker, H. T., & McCoy, J. P. (2010) · Nature Immunology · doi:10.1038/ni1110-975 · Cited by 155
Cited by
Fraietta, J. A., Lacey, S. F., Orlando, E. J., Pruteanu-Malinici, I., Gohil, M., Lundh, S., Boesteanu, A. C., Wang, Y., O’Connor, R. S., Hwang, W.-T., et al. (2018) · Nature Medicine · doi:10.1038/s41591-018-0010-1 · Cited by 1,785
Standardizing immunophenotyping for the Human Immunology Project
Maecker, H. T., McCoy, J. P., & Nussenblatt, R. (2012) · Nature Reviews Immunology · doi:10.1038/nri3158 · Cited by 1,176
Guidelines for the use of flow cytometry and cell sorting in immunological studies (second edition)
Cossarizza, A., Chang, H., Radbruch, A., Acs, A., Adam, D., Adam‐Klages, S., Agace, W. W., Aghaeepour, N., Akdis, M., Allez, M., et al. (2019) · European Journal of Immunology · doi:10.1002/eji.201970107 · Cited by 979
Self-citationA deep profiler's guide to cytometry
Bendall, S. C., Nolan, G. P., Roederer, M., & Chattopadhyay, P. K. (2012) · Trends in Immunology · doi:10.1016/j.it.2012.02.010 · Cited by 656
Self-citationCritical assessment of automated flow cytometry data analysis techniques
The FlowCAP Consortium, Aghaeepour, N., The DREAM Consortium, Finak, G., Hoos, H., Mosmann, T. R., Brinkman, R., Gottardo, R., & Scheuermann, R. H. (2013) · Nature Methods · doi:10.1038/nmeth.2365 · Cited by 598
Self-citation
Metadata
- Authors
- Aghaeepour, N., Chattopadhyay, P. K., Ganesan, A., O'Neill, K., Zare, H., Jalali, A., Hoos, H. H., Roederer, M., & Brinkman, R. R.
- Venue
- Bioinformatics
- Publisher
- Oxford University Press (OUP)
- Published
- 2012-02-29
- Volume
- 28
- Issue
- 7
- Pages
- 1009-1016
- ISSN
- 1367-4803 (ISSN-L)
- 1367-4811
- OpenAlex
- W2158404603
- Cited by
- 69
- References
- 6
- FWCI
- 4.74
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.