IsoCor: isotope correction for high-resolution MS labeling experiments
Open accessThe DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
Summary: Mass spectrometry (MS) is widely used for isotopic studies of metabolism and other (bio)chemical processes. Quantitative applications in systems and synthetic biology require to correct the raw MS data for the contribution of naturally occurring isotopes. Several tools are available to correct low-resolution MS data, and recent developments made substantial improvements by introducing resolution-dependent correction methods, hence opening the way to the correction of high-resolution MS (HRMS) data. Nevertheless, current HRMS correction methods partly fail to determine which isotopic species are resolved from the tracer isotopologues and should thus be corrected. We present an updated version of our isotope correction software (IsoCor) with a novel correction algorithm which ensures to accurately exploit any chemical species with any isotopic tracer, at any MS resolution. IsoCor v2 also includes a novel graphical user interface for intuitive use by end-users and a command-line interface to streamline integration into existing pipelines. Availability and implementation: IsoCor v2 is implemented in Python 3 and was tested on Windows, Unix and MacOS platforms. The source code and the documentation are freely distributed under GPL3 license at https://github.com/MetaSys-LISBP/IsoCor/ and https://isocor.readthedocs.io/.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Limited Memory Algorithm for Bound Constrained Optimization
Byrd, R. H., Lu, P., Nocedal, J., & Zhu, C. (1995) · SIAM Journal on Scientific Computing · doi:10.1137/0916069 · Cited by 6,221
Determination of confidence intervals of metabolic fluxes estimated from stable isotope measurements
Antoniewicz, M. R., Kelleher, J. K., & Stephanopoulos, G. (2006) · Metabolic Engineering · doi:10.1016/j.ymben.2006.01.004 · Cited by 449
Metabolite Spectral Accuracy on Orbitraps
Su, X., Lu, W., & Rabinowitz, J. D. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b00396 · Cited by 285
IsoCor: correcting MS data in isotope labeling experiments
Millard, P., Letisse, F., Sokol, S., & Portais, J.-C. (2012) · Bioinformatics · doi:10.1093/bioinformatics/bts127 · Cited by 278
Self-citationCorrecting mass isotopomer distributions for naturally occurring isotopes
Van Winden, W. A., Wittmann, C., Heinzle, E., & Heijnen, J. J. (2002) · Biotechnology and Bioengineering · doi:10.1002/bit.10393 · Cited by 229
Heinrich, P., Kohler, C., Ellmann, L., Kuerner, P., Spang, R., Oefner, P. J., & Dettmer, K. (2018) · Scientific Reports · doi:10.1038/s41598-018-36293-4 · Cited by 180
The importance of accurately correcting for the natural abundance of stable isotopes
Midani, F. S., Wynn, M. L., & Schnell, S. D. (2017) · Analytical Biochemistry · doi:10.1016/j.ab.2016.12.011 · Cited by 68
The isotopic mass defect: a tool for limiting molecular formulas by accurate mass
Thurman, E. M., & Ferrer, I. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-3562-6 · Cited by 62
Heuillet, M., Bellvert, F., Cahoreau, E., Létisse, F., Millard, P., & Portais, J. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b03886 · Cited by 51
Self-citationComprehensive assessment of measurement uncertainty in 13C-based metabolic flux experiments
Mairinger, T., Wegscheider, W., Peña, D. A., Steiger, M. G., Koellensperger, G., Zanghellini, J., & Hann, S. (2018) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-018-1017-7 · Cited by 16
Cited by
A non-canonical tricarboxylic acid cycle underlies cellular identity
Arnold, P. K., Jackson, B. T., Paras, K. I., Brunner, J. S., Hart, M. L., Newsom, O. J., Alibeckoff, S. P., Endress, J., Drill, E., Sullivan, L. B., et al. (2022) · Nature · doi:10.1038/s41586-022-04475-w · Cited by 304
Lactate Rewires Lipid Metabolism and Sustains a Metabolic–Epigenetic Axis in Prostate Cancer
Ippolito, L., Comito, G., Parri, M., Iozzo, M., Duatti, A., Virgilio, F., Lorito, N., Bacci, M., Pardella, E., Sandrini, G., et al. (2022) · Cancer Research · doi:10.1158/0008-5472.can-21-0914 · Cited by 174
Metadata
- Authors
- Millard, P., Delépine, B., Guionnet, M., Heuillet, M., Bellvert, F., & Létisse, F.
- Venue
- Bioinformatics
- Publisher
- Oxford University Press (OUP)
- Published
- 2019-03-23
- Volume
- 35
- Issue
- 21
- Pages
- 4484-4487
- ISSN
- 1367-4803 (ISSN-L)
- 1367-4811
- OpenAlex
- W2937049592
- Cited by
- 194
- References
- 10
- FWCI
- 4.23
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: IsoCor: isotope correction for high-resolution MS labeling experiments. https://app.cochat.ai/papers/10.1093/bioinformatics/btz209
- The paper
- Millard, P., Delépine, B., Guionnet, M., Heuillet, M., Bellvert, F., & Létisse, F. (2019). IsoCor: isotope correction for high-resolution MS labeling experiments. Bioinformatics. https://doi.org/10.1093/bioinformatics/btz209
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.