A Structural Basis for How Motile Cilia Beat
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The motile cilium is a mechanical wonder, a cellular nanomachine that produces a high-speed beat based on a cycle of bends that move along an axoneme made of 9+2 microtubules. The molecular motors, dyneins, power the ciliary beat. The dyneins are compacted into inner and outer dynein arms, whose activity is highly regulated to produce microtubule sliding and axonemal bending. The switch point hypothesis was developed long ago to account for how sliding in the presence of axonemal radial spoke-central pair interactions causes the ciliary beat. Since then, a new genetic, biochemical, and structural complexity has been discovered, in part, with Chlamydomonas mutants, with high-speed, high-resolution analysis of movement and with cryoelectron tomography. We stand poised on the brink of new discoveries relating to the molecular control of motility that extend and refine our understanding of the basic events underlying the switching of arm activity and of bend formation and propagation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Stages of ciliogenesis and regulation of ciliary length
Avasthi, P., & Marshall, W. F. (2012) · Differentiation · doi:10.1016/j.diff.2011.11.015 · Cited by 234 · cited 1×
“…and regulators of motility Chlamydomonas mutants have been particularly informative, yielding insight into the composition and structure of the axoneme, the regulation of motility, the role of different dynein motors, and the assembly and length regulation of the cilium (Avasthi and Marshall 2012).”
Background
Cited by
Wallmeier, J., Nielsen, K. G., Kuehni, C. E., Lucas, J. S., Leigh, M. W., Zariwala, M. A., & Omran, H. (2020) · Nature Reviews Disease Primers · doi:10.1038/s41572-020-0209-6 · Cited by 403
Magnetic Actuation Methods in Bio/Soft Robotics
Ebrahimi, N., Bi, C., Cappelleri, D. J., Ciuti, G., Conn, A. T., Faivre, D., Habibi, N., Hošovský, A., Iacovacci, V., Khalil, I. S. M., et al. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202005137 · Cited by 353
Jiao, S.-Y., Yang, Y.-H., & Chen, S.-R. (2021) · Human Reproduction Update · doi:10.1093/humupd/dmaa034 · Cited by 276
Axoneme Structure from Motile Cilia
Ishikawa, T. (2017) · Cold Spring Harbor Perspectives in Biology · doi:10.1101/cshperspect.a028076 · Cited by 255
Jungnickel, M. K., Sutton, K. A., Baker, M. A., Cohen, M. G., Sanderson, M. J., & Florman, H. M. (2018) · Biology of Reproduction · doi:10.1093/biolre/ioy105 · Cited by 27
Metadata
- Authors
- Satir, P., Heuser, T., & Sale, W. S.
- Venue
- BioScience
- Publisher
- Oxford University Press (OUP)
- Published
- 2014-11-25
- Volume
- 64
- Issue
- 12
- Pages
- 1073-1083
- ISSN
- 0006-3568 (ISSN-L)
- 1525-3244
- OpenAlex
- W2088290371
- Cited by
- 127
- References
- 1
- FWCI
- 2.77
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Structural Basis for How Motile Cilia Beat. https://app.cochat.ai/papers/10.1093/biosci/biu180
- The paper
- Satir, P., Heuser, T., & Sale, W. S. (2014). A Structural Basis for How Motile Cilia Beat. BioScience. https://doi.org/10.1093/biosci/biu180
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.