CoChat

High STOP-Bang score indicates a high probability of obstructive sleep apnoea

Open access
Chung, F., Subramanyam, R., Liao, P., Sasaki, E., Shapiro, C., Sun, Y. · 2012 · British Journal of Anaesthesia

The DOI matches its Crossref record; 34 of the 36 references it cites were found in a registry or an index.

Abstract

BACKGROUND: The STOP-Bang questionnaire is used to screen patients for obstructive sleep apnoea (OSA). We evaluated the association between STOP-Bang scores and the probability of OSA. METHODS: After Institutional Review Board approval, patients who visited the preoperative clinics for a scheduled inpatient surgery were approached for informed consent. Patients answered STOP questionnaire and underwent either laboratory or portable polysomnography (PSG). PSG recordings were scored manually. The BMI, age, neck circumference, and gender (Bang) were documented. Over 4 yr, 6369 patients were approached and 1312 (20.6%) consented. Of them, 930 completed PSG, and 746 patients with complete data on PSG and STOP-Bang questionnaire were included for data analysis. RESULTS: The median age of 746 patients was 60 yr, 49% males, BMI 30 kg m(-2), and neck circumference 39 cm. OSA was present in 68.4% with 29.9% mild, 20.5% moderate, and 18.0% severe OSA. For a STOP-Bang score of 5, the odds ratio (OR) for moderate/severe and severe OSA was 4.8 and 10.4, respectively. For STOP-Bang 6, the OR for moderate/severe and severe OSA was 6.3 and 11.6, respectively. For STOP-Bang 7 and 8, the OR for moderate/severe and severe OSA was 6.9 and 14.9, respectively. The predicted probabilities for moderate/severe OSA increased from 0.36 to 0.60 as the STOP-Bang score increased from 3 to 7 and 8. CONCLUSIONS: In the surgical population, a STOP-Bang score of 5-8 identified patients with high probability of moderate/severe OSA. The STOP-Bang score can help the healthcare team to stratify patients for unrecognized OSA, practice perioperative precautions, or triage patients for diagnosis and treatment.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/bja/aes022

Cites

34 of 34 references verified0 citation errors · 0 not checkable

Statistics

Figures

Fig 1 Screening flow chart of patients. PSG, polysomnography.
Fig 1 Screening flow chart of patients. PSG, polysomnography.CC BY-NC · PubMed Central
Fig 2 Distribution of patients according to their STOP-Bang score.
Fig 2 Distribution of patients according to their STOP-Bang score.CC BY-NC · PubMed Central
Fig 3 Plot of predicted probabilities for AHI cut-offs of >5, >15, and >30 with the corresponding STOP-Bang score. The vertical bars indicate the 95% confidence intervals. STOP-Bang scores of 0, 1, and 2 are grouped together and are shown as score 2. Scores 7 and 8 are grouped together and is shown as score 7. As the STOP-Bang scores increased, the predicted probabilities were greater. AHI, apnoea–hypopnoea index.
Fig 3 Plot of predicted probabilities for AHI cut-offs of >5, >15, and >30 with the corresponding STOP-Bang score. The vertical bars indicate the 95% confidence intervals. STOP-Bang scores of 0, 1, and 2 are grouped together and are shown as score 2. Scores 7 and 8 are grouped together and is shown as score 7. As the STOP-Bang scores increased, the predicted probabilities were greater. AHI, apnoea–hypopnoea index.CC BY-NC · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 34 references

Cited by

Items 801–900 of 1,000

Metadata

Authors
Chung, F., Subramanyam, R., Liao, P., Sasaki, E., Shapiro, C., & Sun, Y.
Affiliations
University Health Network (CA)
Corresponding author
Chung, F.
Venue
British Journal of Anaesthesia
Publisher
Elsevier BV
Published
2012-05
Volume
108
Issue
5
Pages
768-775
ISSN
0007-0912 (ISSN-L)
OpenAlex
W2130254450
Cited by
988
References
36
Citations by year
2026: 31 · 2025: 82 · 2024: 67 · 2023: 50 · 2022: 58 · 2021: 93 · 2020: 77 · 2019: 65 · 2018: 82 · 2017: 120 · 2016: 72 · 2015: 69 · 2014: 63 · 2013: 40 · 2012: 16
FWCI
40.30
Type
journal article
Language
en
Open access
Licence
Locations
  • British Journal of Anaesthesia (publishedVersion, cc-by-nc)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by-nc)
  • PubMed Central (publishedVersion, cc-by-nc)
  • PubMed (publishedVersion)
Funders
  • ResMed
  • University of Toronto
  • University Health Network Foundation
Topics
  • Health Sciences › Medicine › Physiology (medical) › Obstructive Sleep Apnea Research
  • Social Sciences › Psychology › Experimental and Cognitive Psychology › Sleep and related disorders
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Chronic Obstructive Pulmonary Disease (COPD) Research
Keywords
obstructive sleep apnea, STOP-BANG questionnaire, OSA screening, polysomnography, preoperative screening, surgical patients, OSA severity, patient stratification
MeSH terms
Aged, Female, Humans, Male, Mass Screening, Middle Aged, Neck, Predictive Value of Tests, Prospective Studies, Severity of Illness Index, Body Mass Index, Polysomnography, Sleep Apnea, Obstructive

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.