Alternative intubation techniques vs Macintosh laryngoscopy in patients with cervical spine immobilization: systematic review and meta-analysis of randomized controlled trials
Open accessAbstract
BACKGROUND: Immobilization of the cervical spine worsens tracheal intubation conditions. Various intubation devices have been tested in this setting. Their relative usefulness remains unclear. METHODS: We searched MEDLINE, EMBASE, and the Cochrane Library for randomized controlled trials comparing any intubation device with the Macintosh laryngoscope in human subjects with cervical spine immobilization. The primary outcome was the risk of tracheal intubation failure at the first attempt. Secondary outcomes were quality of glottis visualization, time until successful intubation, and risk of oropharyngeal complications. RESULTS: Twenty-four trials (1866 patients) met inclusion criteria. With alternative intubation devices, the risk of intubation failure was lower compared with Macintosh laryngoscopy [risk ratio (RR) 0.53; 95% confidence interval (CI) 0.35-0.80]. Meta-analyses could be performed for five intubation devices (Airtraq, Airwayscope, C-Mac, Glidescope, and McGrath). The Airtraq was associated with a statistically significant reduction of the risk of intubation failure at the first attempt (RR 0.14; 95% CI 0.06-0.33), a higher rate of Cormack-Lehane grade 1 (RR 2.98; 95% CI 1.94-4.56), a reduction of time until successful intubation (weighted mean difference -10.1 s; 95% CI -3.2 to -17.0), and a reduction of oropharyngeal complications (RR 0.24; 95% CI 0.06-0.93). Other devices were associated with improved glottis visualization but no statistically significant differences in intubation failure or time to intubation compared with conventional laryngoscopy. CONCLUSIONS: In situations where the spine is immobilized, the Airtraq device reduces the risk of intubation failure. There is a lack of evidence for the usefulness of other intubation devices.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Indirect hyperangulated video laryngoscopy (VL) consistently provides an improved glottic view.
“indirect hyperangulated video laryngoscopy (VL) consistently provides an improved glottic view”
From Airway Management in Trauma (2018) · cites this paper as [45]
The Results (Cormack–Lehane grade; page not provided) report significantly better glottic views than Macintosh laryngoscopy for each of five evaluated devices. The claim omits the study's restriction to adults with cervical spine immobilization and describes the devices collectively as indirect hyperangulated VL, a category the reported result does not establish for all five. (LLM, conf=0.85)
Experimental — accuracy not yet measuredC-spine immobilization consistently impairs the glottic view with DL.
“c-spine immobilization consistently impairs the glottic view with DL”
From Airway Management in Trauma (2018) · cites this paper as [45]
The paper's background says cervical spine immobilization may disrupt airway alignment and jeopardize glottic visualization during direct laryngoscopy. Its Results (Cormack–Lehane grade; page unavailable) also report poorer glottic views with Macintosh laryngoscopy than with alternative devices in immobilized patients. Neither passage establishes that immobilization consistently impairs the view compared with no immobilization, so “consistently” overstates the evidence. (LLM, conf=0.86)
Experimental — accuracy not yet measuredA recent meta-analysis by Suppan and colleagues reported more failed intubations for DL compared with several alternative intubating devices in patients with c-spine immobilization.
“A recent meta-analysis by Suppan and colleagues 45 reported more failed intubations for DL compared with several alternative intubating devices in patients with c-spine immobilization.”
From Airway Management in Trauma (2018) · cites this paper as [45]
The Results (‘Intubation failure at first attempt’; page not provided) report more first-attempt failures with Macintosh laryngoscopy than with alternative devices pooled. But among the five devices analysed individually, only Airtraq significantly reduced failures; the other four did not show a significant difference. The claim overstates the device-specific finding by implying that several alternatives each had fewer failures. (LLM, conf=0.88)
Experimental — accuracy not yet measuredThere was no statistically significant difference in first-attempt success between the more commonly used VL devices (GlideScope, C-MAC) and DL.
“there was no statistically significant difference in first-attempt success between the more commonly used VL devices (GlideScope, C-MAC) and DL. 45”
From Airway Management in Trauma (2018) · cites this paper as [45]
Literature comparing intubation devices in c-spine immobilized patients has yielded inconsistent findings, and no consensus as to the optimal approach.
“Literature comparing intubation devices in c-spine immobilized patients has yielded inconsistent findings, and no consensus as to the optimal approach.38,44,45,48,49”
From Airway Management in Trauma (2018) · cites this paper as [45]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Preferred reporting items for systematic reviews and meta-analyses: The PRISMA statement
Moher, D., Liberati, A., Tetzlaff, J., & Altman, D. G. (2010) · International Journal of Surgery · doi:10.1016/j.ijsu.2010.02.007 · Cited by 12,156 · see citing works
Flagged first, then by citations
Research works printed but not linked: 43
- [1]Hastings RH Kelley SD Neurologic deterioration associated with airway management in a cervical spine-injured patient. Anesthesiology 1993; 78: 580– 3 8457057
- [3]Mayglothling J Duane TM Gibbs M Emergency tracheal intubation immediately following traumatic injury: an Eastern Association for the Surgery of Trauma practice management guideline. J Trauma Acute Care Surg 2012; 73: S333– 40 23114490
- [4]Lennarson PJ Smith DW Sawin PD Todd MM Sato Y Traynelis VC Cervical spinal motion during intubation: efficacy of stabilization maneuvers in the setting of complete segmental instability. J Neurosurg 2001; 94: 265– 70 11302629
- [5]Gerling MC Davis DP Hamilton RS Effects of cervical spine immobilization technique and laryngoscope blade selection on an unstable cervical spine in a cadaver model of intubation. Ann Emerg Med 2000; 36: 293– 300 11020675
- [6]Thiboutot F Nicole PC Trepanier CA Turgeon AF Lessard MR Effect of manual in-line stabilization of the cervical spine in adults on the rate of difficult orotracheal intubation by direct laryngoscopy: a randomized controlled trial. Can J Anaesth 2009; 56: 412– 8 19396507
- [7]Heath KJ The effect of laryngoscopy of different cervical spine immobilisation techniques. Anaesthesia 1994; 49: 843– 5 7802175
- [8]Goutcher CM Lochhead V Reduction in mouth opening with semi-rigid cervical collars. Br J Anaesth 2005; 95: 344– 8 16006487
- [10]Cormack RS Lehane J Difficult tracheal intubation in obstetrics. Anaesthesia 1984; 39: 1105– 11 6507827
- [11]Elia N Tramer MR Ketamine and postoperative pain – a quantitative systematic review of randomised trials. Pain 2005; 113: 61– 70 15621365
- [12]Mantel N Haenszel W Statistical aspects of the analysis of data from retrospective studies of disease. J Natl Cancer Inst 1959; 22: 719– 48 13655060
- [13]Higgins JP Thompson SG Deeks JJ Altman DG Measuring inconsistency in meta-analyses. Br Med J 2003; 327: 557– 60 12958120 PMC192859
- [14]Taylor AM Peck M Launcelott S The McGrath® Series 5 videolaryngoscope vs the Macintosh laryngoscope: a randomised, controlled trial in patients with a simulated difficult airway. Anaesthesia 2013; 68: 142– 7 23121470
- [15]Amor M Nabil S Bensghir M [A comparison of Airtraq laryngoscope and standard direct laryngoscopy in adult patients with immobilized cervical spine]. Ann Fr Anesth Reanim 2013; 32: 296– 301 23561715
- [16]Aoi Y Inagawa G Nakamura K Sato H Kariya T Goto T Airway Scope versus Macintosh laryngoscope in patients with simulated limitation of neck movements. J Trauma 2010; 69: 838– 42 20179653
- [17]Bharti N Arora S Panda NB A comparison of McCoy, TruView, and Macintosh laryngoscopes for tracheal intubation in patients with immobilized cervical spine. Saudi J Anaesth 2014; 8: 188– 92 24843330 PMC4024674
- [18]Byhahn C Nemetz S Breitkreutz R Zwissler B Kaufmann M Meininger D Brief report: tracheal intubation using the Bonfils intubation fibrescope or direct laryngoscopy for patients with a simulated difficult airway. Can J Anaesth 2008; 55: 232– 7 18378968
- [19]Gercek E Wahlen BM Rommens PM In vivo ultrasound real-time motion of the cervical spine during intubation under manual in-line stabilization: a comparison of intubation methods. Eur J Anaesthesiol 2008; 25: 29– 36 17662163
- [20]Gupta N Rath GP Prabhakar H Clinical evaluation of C_MAC videolaryngoscope with or without the use of stylet for endotracheal intubation in patients with cervical spine immobilization. J Anesth 2013; 27: 663– 70 23475442
- [21]Ilyas S Symons J Bradley WP A prospective randomised controlled trial comparing tracheal intubation plus manual in-line stabilisation of the cervical spine using the Macintosh laryngoscope vs the McGrath® Series 5 videolaryngoscope. Anaesthesia 2014; 69: 1345– 50 25087907
- [22]Kihara S Yaguchi Y Taguchi N Brimacombe JR Watanabe S The StyletScope is a better intubation tool than a conventional stylet during simulated cervical spine immobilization. Can J Anaesth 2005; 52: 105– 10 15625266
- [23]Koh JC Lee JS Lee YW Chang CH Comparison of the laryngeal view during intubation using Airtraq and Macintosh laryngoscopes in patients with cervical spine immobilization and mouth opening limitation. Korean J Anesthesiol 2010; 59: 314– 8 21179292 PMC2998650
- [24]Kok T George RB McKeen D Vakharia N Pink A Effectiveness and safety of the Levitan FPS Scope for tracheal intubation under general anesthesia with a simulated difficult airway. Can J Anaesth 2012; 59: 743– 50 22585469
- [25]Lim Y Yeo SW A comparison of the GlideScope with the Macintosh laryngoscope for tracheal intubation in patients with simulated difficult airway. Anaesth Intensive Care 2005; 33: 243– 7 15960409
- [26]Maharaj CH Buckley E Harte BH Laffey JG Endotracheal intubation in patients with cervical spine immobilization: a comparison of Macintosh and Airtraq laryngoscopes. Anesthesiology 2007; 107: 53– 9 17585215
- [27]Malik MA Maharaj CH Harte BH Laffey JG Comparison of Macintosh®, Truview EVO2®, Glidescope®, and Airwayscope® laryngoscope use in patients with cervical spine immobilization. Br J Anaesth 2008; 101: 723– 30 18784069
- [28]Malik MA Subramaniam R Churasia S Maharaj CH Harte BH Laffey JG Tracheal intubation in patients with cervical spine immobilization: a comparison of the Airwayscope®, LMA CTrach®, and the Macintosh laryngoscopes. Br J Anaesth 2009; 102: 654– 61 19336535
- [29]Maruyama K Yamada T Kawakami R Hara K Randomized cross-over comparison of cervical-spine motion with the AirWay Scope or Macintosh laryngoscope with in-line stabilization: a video-fluoroscopic study. Br J Anaesth 2008; 101: 563– 7 18660500
- [30]McElwain J Laffey JG Comparison of the C-MAC®, Airtraq®, and Macintosh laryngoscopes in patients undergoing tracheal intubation with cervical spine immobilization. Br J Anaesth 2011; 107: 258– 64 21586444
- [31]Robitaille A Williams SR Tremblay MH Guilbert F Thériault M Drolet P Cervical spine motion during tracheal intubation with manual in-line stabilization: direct laryngoscopy versus GlideScope® videolaryngoscopy. Anesth Analg 2008; 106: 935– 41, table of contents 18292443
- [32]Smith CE Pinchak AB Sidhu TS Radesic BP Pinchak AC Hagen JF Evaluation of tracheal intubation difficulty in patients with cervical spine immobilization: fiberoptic (WuScope) versus conventional laryngoscopy. Anesthesiology 1999; 91: 1253– 9 10551574
- [33]Tolon MA Zanaty OM Shafshak W Arida EE Comparative study between the use of Macintosh Laryngoscope and Airtraq in patients with cervical spine immobilization. Alexandria Journal of Medicine 2012; 48: 179– 85
- [34]Turkstra TP Craen RA Pelz DM Gelb AW Cervical spine motion: a fluoroscopic comparison during intubation with lighted stylet, GlideScope, and Macintosh laryngoscope. Anesth Analg 2005; 101: 910– 5, table of contents 16116013
- [35]Turkstra TP Pelz DM Jones PM Cervical spine motion: a fluoroscopic comparison of the AirTraq laryngoscope versus the Macintosh laryngoscope. Anesthesiology 2009; 111: 97– 101 19512871
- [36]Turkstra TP Pelz DM Shaikh AA Craen RA Cervical spine motion: a fluoroscopic comparison of Shikani Optical Stylet vs Macintosh laryngoscope. Can J Anaesth 2007; 54: 441– 7 17541072
- [37]Watts AD Gelb AW Bach DB Pelz DM Comparison of the Bullard and Macintosh laryngoscopes for endotracheal intubation of patients with a potential cervical spine injury. Anesthesiology 1997; 87: 1335– 42 9416718
- [38]Gaszynska E Stankiewicz-Rudnicki M Wieczorek A Gaszynski T A comparison of conventional tube and EndoFlex tube for tracheal intubation in patients with a cervical spine immobilisation. Scand J Trauma Resusc Emerg Med 2013; 21: 79 24267640 PMC4222123
- [39]Lu Y Jiang H Zhu YS Airtraq laryngoscope versus conventional Macintosh laryngoscope: a systematic review and meta-analysis. Anaesthesia 2011; 66: 1160– 7 21883130
- [40]Norman A Date A Use of the Airtraq laryngoscope for anticipated difficult laryngoscopy. Anaesthesia 2007; 62: 533– 4 17448079
- [41]Schulz KF Chalmers I Hayes RJ Altman DG Empirical evidence of bias. Dimensions of methodological quality associated with estimates of treatment effects in controlled trials. JAMA 1995; 273: 408– 12 7823387
- [42]Hurford D Cook T Nolan J Mihai R Control group bias: a potential cause of over-estimating the benefit of videolaryngoscopy on laryngeal view. Br J Anaesth 2013; 111: 124– 5 23794660
- [43]Hirabayashi Y Fujita A Seo N Sugimoto H A comparison of cervical spine movement during laryngoscopy using the Airtraq or Macintosh laryngoscopes. Anaesthesia 2008; 63: 635– 40 18477276
- [44]Hirabayashi Y Fujita A Seo N Sugimoto H Cervical spine movement during laryngoscopy using the Airway Scope compared with the Macintosh laryngoscope. Anaesthesia 2007; 62: 1050– 5 17845658
- [45]Prasarn ML Conrad B Rubery PT Comparison of 4 airway devices on cervical spine alignment in a cadaver model with global ligamentous instability at C5–C6. Spine (Phila Pa 1976) 2012; 37: 476– 81 21629162
Cited by
Sorted by citations
Kovacs, G., & Sowers, N. (2018) · Emergency Medicine Clinics of North America · doi:10.1016/j.emc.2017.08.006 · Cited by 115 · see citing works
- Authors
- Suppan, L., Tramèr, M. R., Niquille, M., Grosgurin, O., & Marti, C.
- Affiliations
- University Hospital of Geneva (CH)
- University of Geneva (CH)
- Corresponding author
- Suppan, L.
- Venue
- British Journal of Anaesthesia
- Publisher
- Elsevier BV
- Published
- 2016-01
- Volume
- 116
- Issue
- 1
- Pages
- 27-36
- ISSN
- 0007-0912 (ISSN-L)
- PMC
- PMC4681615
- OpenAlex
- W2198408822
- Cited by
- 126
- References
- 1
- Citations by year
- 2026: 4 · 2025: 9 · 2024: 9 · 2023: 6 · 2022: 10 · 2021: 13 · 2020: 17 · 2019: 8 · 2018: 10 · 2017: 25 · 2016: 11 · 2015: 3 · 2014: 1
- FWCI
- 3.22
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- Locations
- British Journal of Anaesthesia (publishedVersion, cc-by-nc)
- Europe PMC (PubMed Central) (publishedVersion, cc-by-nc)
- PubMed Central (publishedVersion, cc-by-nc)
- PubMed (publishedVersion)
- Archive ouverte UNIGE (University of Geneva) (publishedVersion, other-oa)
- Archive ouverte UNIGE (University of Geneva) (submittedVersion, cc-by)
- Topics
- Health Sciences › Medicine › Anesthesiology and Pain Medicine › Airway Management and Intubation Techniques
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Tracheal and airway disorders
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Respiratory Support and Mechanisms
- Keywords
- difficult intubation, cervical spine immobilization, Macintosh laryngoscope, Airtraq, video laryngoscopy, failed intubation, glottis visualization, Cormack-Lehane grade, intubation time, C-MAC
- MeSH terms
- Cervical Vertebrae, Equipment Design, Humans, Immobilization, Intubation, Intratracheal, Laryngoscopy, Randomized Controlled Trials as Topic, Laryngoscopes
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review