CoChat

Impact of wearable wireless continuous vital sign monitoring in abdominal surgical patients: before–after study

Open access

The DOI matches its Crossref record; 82 of the 83 references it cites were found in a registry or an index.

Abstract

Background: Technological advances have enabled continuous monitoring of vital signs (CMVS) by wearable, wireless devices on general hospital wards to facilitate early detection of clinical deterioration, which could potentially improve clinical outcomes. However, evidence on the impact of these CMVS systems on patient outcomes is limited. This research aimed to explore the effect of CMVS on the clinical outcomes in major abdominal surgery patients in a general surgery ward. Methods: A single-centre before–after study was conducted from October 2019 to June 2022. Patients in the intervention group received CMVS in addition to conventional intermittent vital sign monitoring (standard care for control group). With CMVS, heart rate and respiratory rate were measured every 5 min by a patch sensor. Proactive vital signs trends assessments and, when necessary, subsequent nursing activities were performed every nursing shift. The primary outcome of interest was the length of hospital stay (LOS); also, 12 patient-related outcomes were analysed. In the CMVS group, follow-up nursing activities of deviating vital signs trends were described and patient acceptability was measured. Post-hoc subgroup analysis was performed for colorectal and hepatopancreatobiliary surgery. Results: A total of 908 patients were included (colorectal: n = 650; hepatopancreatobiliary: n = 257). Overall, median LOS was lower in the CMVS group (5.0 versus 5.5 days; P = 0.012), respectively. Post-hoc subgroup analysis showed this reduction in LOS was mostly observed in the colorectal group and not in the hepatopancreatobiliary group. Apart from a decrease in nurse-to-house-officer calls (from 15.3% to 7.7%; P = 0.007), all secondary clinical outcomes were similar in CMVS and control groups. However, a non-significant trend towards less-severe complications and reduced ICU LOS was observed in the CMVS group. In CMVS patients, 109 additional nursing activities were performed and 83% of patients indicated CMVS was acceptable. Conclusion: CMVS was associated with a significant reduction in LOS, while other clinical outcomes were unchanged. CMVS triggered additional nursing activities such as extra patient assessments and therapeutic interventions.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/bjsopen/zrad128

Cites

82 of 82 references verified0 citation errors · 0 not checkable

Statistics

Figures

Fig. 1 Flowchart of the study HPB, hepatopancreatobiliary.
Fig. 1 Flowchart of the study HPB, hepatopancreatobiliary.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 82 references

Research works printed but not linked: 1

  1. [34]34. Leenen JPL, Rasing H, Kalkman CJ, Schoonhoven L, Patijn GA. Process evaluation of a wireless wearable continuous vital signs monitoring intervention in 2 general hospital wards: mixed methods study. JMIR Nurs 2023;6:e44061

Cited by

See all 36

Metadata

Authors
Leenen, J. P. L., Ardesch, V., Kalkman, C. J., Schoonhoven, L., & Patijn, G. A.
Affiliations
  • Windesheim University of Applied Sciences (NL)
  • Isala (NL)
  • Utrecht University (NL)
Corresponding author
Leenen, Jobbe P L
Venue
BJS Open
Published
2024-01-03
Volume
8
Issue
1
ISSN
2474-9842 (ISSN-L)
OpenAlex
W4390987008
Cited by
36
References
83
Citations by year
2026: 14 · 2025: 17 · 2024: 5
FWCI
9.65
Type
journal article
Language
en
Open access
Locations
  • BJS Open (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • Utrecht University Repository (Utrecht University) (submittedVersion, other-oa)
  • ResearchSpace (University of Auckland) (submittedVersion, cc-by)
Funders
Isala Innovation & Science Funds (INNO2016)
Topics
  • Health Sciences › Medicine › Surgery › Healthcare Technology and Patient Monitoring
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Surgery › Hemodynamic Monitoring and Therapy
Keywords
continuous vital sign monitoring, wearable sensors, abdominal surgery, length of hospital stay, colorectal surgery, hepatopancreatobiliary surgery, early detection of clinical deterioration, nursing activities, patient acceptability, postoperative complications, ICU length of stay
MeSH terms
Wearable Electronic Devices, Humans, Length of Stay, Colorectal Neoplasms, Vital Signs, Controlled Before-After Studies

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Impact of wearable wireless continuous vital sign monitoring in abdominal surgical patients: before–after study. https://app.cochat.ai/papers/10.1093/bjsopen/zrad128
The paper
Leenen, J. P. L., Ardesch, V., Kalkman, C. J., Schoonhoven, L., & Patijn, G. A. (2024). Impact of wearable wireless continuous vital sign monitoring in abdominal surgical patients: before–after study. BJS Open. https://doi.org/10.1093/bjsopen/zrad128

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.