The DOI matches its Crossref record.
THE CARPAL TUNNEL SYNDROME: LOCALIZATION OF CONDUCTION ABNORMALITIES WITHIN THE DISTAL SEGMENT OF THE MEDIAN NERVE|_1
Abstract
Palmar stimulation was used to assess median nerve conduction across the carpal tunnel in 61 control patients and 105 patients with the carpal tunnel syndrome. With serial stimulation from midpalm to distal forearm the sensory axons normally showed a predictable latency change of 0.16 to 0.21 ms/cm as the stimulus site was moved proximally in 1 cm increments. In 47 (52 per cent) of 91 affected nerves tested serially, there was a sharply localized latency increase across a 1 cm segment, most commonly 2 to 4 cm distally to the origin of the transverse carpal ligament. In these hands, the focal latency change across the affected 1 cm segment (mean +/- SD: 0.80 +/- 0.22 ms/cm) averaged more than four times that of the adjoining distal (0.19 +/- 0.09 ms/cm) or proximal 1 cm segments (0.19 +/- 0.08 ms/cm). In the remaining 44 (48 per cent) hands, the latency increase was distributed more evenly across the carpal tunnel. Unlike the sensory axons the motor axons were difficult to test serially because of the recurrent course of the thenar nerve, which may be contained in a separate tunnel. The wrist-to-palm latency was significantly greater in the patients with carpal tunnel syndromes than in the controls for sensory (2.18 +/- 0.48 ms v 1.41 +/- 0.18 ms) and motor axons (2.79 +/- 0.93 ms v 1.50 +/- 0.21 ms). Consequently, there was considerable difference between the carpal tunnel syndromes and controls in SNCV (38.5 +/- 7.5 m/s v 57.3 +/- 6.9 m/s), and MNCV (28.2 +/- 4.5 m/s v 49.0 +/- 5.7 m/s). In the remaining distal segment, however, there was only a small difference between the two groups in sensory (1.48 +/- 0.28 ms v 1.41 +/- 0.22 ms) and motor latency (2.15 +/- 0.34 ms v 2.10 +/- 0.31 ms). The exclusion of the relatively normal distal latency made it possible to demonstrate mild slowing across the carpal tunnel in 36 (21 per cent) sensory and 40 (23 per cent) motor axons of 172 affected nerves when the conventional terminal latencies were normal. Sensory or motor conduction abnormalities were found in all but 13 (8 per cent) hands. Without palmar stimulation, however, an additional 32 (19 per cent) hands would have been regarded as normal.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
AAEM minimonograph #26: The electrodiagnosis of carpal tunnel syndrome
Stevens, J. C. (1997) · Muscle & Nerve · doi:10.1002/(sici)1097-4598(199712)20:12 · Cited by 518
The validity of upper-limb neurodynamic tests for detecting peripheral neuropathic pain.
Nee, R. J., Jull, G. A., Vicenzino, B., & Coppieters, M. W. (2012) · Journal of Orthopaedic & Sports Physical Therapy · doi:10.2519/jospt.2012.3988 · Cited by 171
NATHAN, P. A., KENISTON, R. C., & MEADOWS, K. D. (1995) · Journal of Hand Surgery · doi:10.1016/s0266-7681(05)80125-1 · Cited by 96
Metadata
- Authors
- KIMURA, J.
- Venue
- Brain
- Publisher
- Oxford University Press (OUP)
- Published
- 1979
- Volume
- 102
- Issue
- 3
- Pages
- 619-635
- ISSN
- 0006-8950 (ISSN-L)
- 1460-2156
- OpenAlex
- W2014712452
- Cited by
- 755
- References
- 0
- FWCI
- 9.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: THE CARPAL TUNNEL SYNDROME: LOCALIZATION OF CONDUCTION ABNORMALITIES WITHIN THE DISTAL SEGMENT OF THE MEDIAN NERVE|_1. https://app.cochat.ai/papers/10.1093/brain/102.3.619
- The paper
- KIMURA, J. (1979). THE CARPAL TUNNEL SYNDROME: LOCALIZATION OF CONDUCTION ABNORMALITIES WITHIN THE DISTAL SEGMENT OF THE MEDIAN NERVE|_1. Brain. https://doi.org/10.1093/brain/102.3.619
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.