Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 172

The DOI matches its Crossref record.

AN ELECTROPHYSIOLOGICAL INVESTIGATION INTO THE PAIN-RELIEVING EFFECTS OF HETEROTOPIC NOCICEPTIVE STIMULI: PROBABLE INVOLVEMENT OF A SUPRASPINAL LOOP

ROBY-BRAMI, A., BUSSEL, B., WILLER, J. C., LEBARS, D.·1987·Brain

Abstract

It has previously been shown that, in normal subjects, heterotopic painful stimuli induce parallel decreases in the sensation of pain and the nociceptive spinal flexion reflex RIII simultaneously evoked by electrical stimulation of the sural nerve. By contrast, heterotopic non-noxious stimuli were ineffective in this respect. In order to assess the possible involvement of supraspinal structures in these changes, we have now compared the effects of nociceptive electrical stimuli applied to the fourth and fifth fingers of the hand on the contralateral RIII reflex in 5 normal subjects and 5 tetraplegic patients suffering from a clinically complete spinal cord transection of traumatic origin. The tetraplegic patient had a C5, C6 or C7 spinal cord transection with lower segments, notably C8 and T1, clinically uninjured. In these patients, sural nerve stimulation induced a biceps femoris reflex which did not differ from the RIII reflex recorded in normal subjects, either in terms of latency or of threshold. In both groups, the RIII reflex threshold was determined and a juxta-threshold RIII reflex was studied before, during and after a 2 min period of conditioning stimulation. The conditioning procedure consisted of nociceptive electrical stimulation applied to the digital branches of the ulnar nerve which arises from C8 and T1, i.e., below the level of the patients' spinal transection. In normal subjects such conditioning elicited painful sensations of 'pin prick', 'burning' and 'squeezing'. It simultaneously induced a strong inhibition of the RIII reflex which outlasted the conditioning period by several minutes. By contrast, non-nociceptive electrical conditioning stimuli (0.1 ms duration pulses of 6 to 8 mA intensity, at 3/s), similarly applied to the digital branches of the ulnar nerve were totally ineffective. In tetraplegic patients not only was the RIII reflex never decreased by the heterotopic nociceptive stimulation but it was, in fact, slightly enhanced. These results show that the effects of heterotopic nociceptive stimulation observed in normal man are possibly mediated by a complex loop involving supraspinal structures. This further underlines the similarity between this phenomenon and the Diffuse Noxious Inhibitory Controls (DNIC) described in the rat, since the latter are observed in intact but not in spinal animals. These findings are discussed with reference to counter-irritation phenomena and procedures aimed at producing analgesia by somatic electrical stimulation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/brain/110.6.1497

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Metadata

Authors
ROBY-BRAMI, A., BUSSEL, B., WILLER, J. C., & LEBARS, D.
Venue
Brain
Published
1987
Volume
110
Issue
6
Pages
1497-1508
ISSN
  • 0006-8950 (ISSN-L)
  • 1460-2156
OpenAlex
W1996483810
Cited by
172
References
0
FWCI
2.47
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: AN ELECTROPHYSIOLOGICAL INVESTIGATION INTO THE PAIN-RELIEVING EFFECTS OF HETEROTOPIC NOCICEPTIVE STIMULI: PROBABLE INVOLVEMENT OF A SUPRASPINAL LOOP. https://app.cochat.ai/papers/10.1093/brain/110.6.1497
The paper
ROBY-BRAMI, A., BUSSEL, B., WILLER, J. C., & LEBARS, D. (1987). AN ELECTROPHYSIOLOGICAL INVESTIGATION INTO THE PAIN-RELIEVING EFFECTS OF HETEROTOPIC NOCICEPTIVE STIMULI: PROBABLE INVOLVEMENT OF A SUPRASPINAL LOOP. Brain. https://doi.org/10.1093/brain/110.6.1497

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.