CoChat

Intra- and inter-observer agreement of brain MRI lesion volume measurements in multiple sclerosis: A comparison of techniques

Filippi, M., Horsfield, M. A., Bressi, S., Martinelli, V., Baratti, C., Reganati, P., Campi, A., Miller, D. H., Comi, G. · 1995 · Brain
Cited by 124

The DOI matches its Crossref record.

Abstract

The measurement of MRI lesion load in multiple sclerosis is increasingly being used to evaluate the natural history of the disease and to monitor the efficacy of treatments. If, as might occur in multicentre studies, lesion load is measured by several observers in different patients or by the same observer in serial scans, it would be necessary to utilize a technique which provides results with high inter- and intra-observer agreements. This study was performed to evaluate the intra- and inter-observer agreement of semi-automated lesion volume measurement using thresholding, and to compare them with those obtained using an arbitrary scoring system (ASS) and a quantitative manual tracing method (MTM). Brain MRIs were obtained for 20 clinically definite multiple sclerosis patients and were evaluated independently by three observers. The median intra- and inter-observer agreements were, respectively, 88.5% (range 69.0-96.8%) and 79.0% (range 73.3-98.3%) using the ASS, 95.0% (range 85.1-99.4%) and 93.4% (range 77.3-98.3%) for the MTM, 96.3% (range 94.2-98.9%) and 93.7% (range 83.8-98.3%) for the semi-automated technique. The intra- and inter-observer agreements for the semi-automated technique increased to 98.5% (range 96.3-99.8%) and 96.1% (range 90.5-98.6%) when a consensus in the choice of threshold for lesion segmentation was reached. The intra- and inter-observer agreements were significantly greater for the semi-automated method compared with both the arbitrary scoring and the MTMs. The intra-observer variability for the semi-automated technique was significantly lower (P < 0.0001) than the inter-observer variability obtained using the same technique. These data indicate that it is possible to obtain high intra- and inter-observer agreements using a semi-automatic thresholding technique to quantify lesion volumes in multiple sclerosis. The technique may prove useful in multicentre studies, in which a single observer is still preferable.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/brain/118.6.1593

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 124

Metadata

Authors
Filippi, M., Horsfield, M. A., Bressi, S., Martinelli, V., Baratti, C., Reganati, P., Campi, A., Miller, D. H., & Comi, G.
Venue
Brain
Published
1995
Volume
118
Issue
6
Pages
1593-1600
ISSN
  • 0006-8950 (ISSN-L)
  • 1460-2156
OpenAlex
W2047667601
Cited by
124
References
0
FWCI
6.52
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Intra- and inter-observer agreement of brain MRI lesion volume measurements in multiple sclerosis: A comparison of techniques. https://app.cochat.ai/papers/10.1093/brain/118.6.1593
The paper
Filippi, M., Horsfield, M. A., Bressi, S., Martinelli, V., Baratti, C., Reganati, P., Campi, A., Miller, D. H., & Comi, G. (1995). Intra- and inter-observer agreement of brain MRI lesion volume measurements in multiple sclerosis: A comparison of techniques. Brain. https://doi.org/10.1093/brain/118.6.1593

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.