Regional hippocampal [11C]flumazenil PET in temporal lobe epilepsy with unilateral and bilateral hippocampal sclerosis
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Using statistical parametric mapping and [11C]flumazenil (FMZ) PET we have previously shown reduction of central benzodiazepine receptor (cBZR) binding restricted to the hippocampus in mesial temporal lobe epilepsy due to unilateral hippocampal sclerosis. However, bilateral hippocampal pathology can be present in up to 50% of patients with mesial temporal lobe epilepsy. Additionally, the limited spatial resolution of PET results in a partial volume effect that affects quantitative analysis of cBZRs and such an effect can mask hippocampal dysfunction. We analysed changes in the [11C]FMZ volume of distribution (FMZ-Vd) before and after correction for partial volume effect in six patients with refractory mesial temporal lobe epilepsy and a quantitative MRI diagnosis of bilateral hippocampal sclerosis, which appeared either symmetrical on MRI (bilateral symmetrical hippocampal sclerosis; three patients) or bilateral but asymmetrical (asymmetrical hippocampal sclerosis; three patients), and in nine patients with refractory mesial temporal lobe epilepsy and unilateral hippocampal sclerosis on MRI than was subsequently histologically verified. Fifteen healthy controls were also studied for comparison. Before correction for partial volume effects, significant unilateral reductions of FMZ-Vd were found in one of the three patients with bilateral symmetrical hippocampal sclerosis, in one of the three asymmetrical hippocampal sclerosis patients and in six of the nine unilateral hippocampal sclerosis patients. No significant bilateral reductions of hippocampal FMZ-Vd were detected. After correction for partial volume effect, all three patients with bilateral symmetrical hippocampal sclerosis showed significant bilateral reductions of FMZ-Vd, and these were asymmetrical in two. All three patients with asymmetrical hippocampal sclerosis and all nine patients with unilateral hippocampal sclerosis on MRI showed unilateral reductions of FMZ-Vd concordant with the side of the EEG focus. In addition one of the three patients with asymmetrical hippocampal sclerosis and three of the nine patients with unilateral hippocampal sclerosis showed significant reductions of FMZ-Vd in the hippocampus contralateral to the side of the EEG focus. Absolute quantification of [11C]FMZ-PET, corrected for partial volume effect, within multiple hippocampal volumes of interest was necessary in order to detect bilateral changes of cBZR in mesial temporal lobe epilepsy due to hippocampal sclerosis with optimal sensitivity. This [11C]FMZ-PET approach was able to demonstrate subtle contralateral abnormalities in one-third of patients thought to have unilateral or bilateral asymmetrical hippocampal sclerosis on MRI. Reduction of cBZR binding was consistently over and above loss of hippocampal volume indicating that atrophy is not the sole determinant of cBZR loss in mesial temporal lobe epilepsy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Statistical methods for assessing agreement between two methods of clinical measurement
Bland, J. M., & Altman, D. G. (2010) · International Journal of Nursing Studies · doi:10.1016/j.ijnurstu.2009.10.001 · Cited by 5,220
Cited by
PET and SPECT in epilepsy: a critical review.
la Fougère, C., Rominger, A., Förster, S., Geisler, J., & Bartenstein, P. (2009) · Epilepsy & Behavior · doi:10.1016/j.yebeh.2009.02.025 · Cited by 224
“In unilateral hippocampal sclerosis, reduction of binding of [(11)C]flumazenil has been shown to be confined to the hippocampus and to be over and above that caused by neuron loss and hippocampal atrophy [34].”
BackgroundGABA and Its Receptors in Epilepsy
Sperk, G., Furtinger, S., Schwarzer, C., & Pirker, S. (2004) · Advances in Experimental Medicine and Biology · doi:10.1007/978-1-4757-6376-8_7 · Cited by 193
Progressive neocortical damage in epilepsy
Liu, R. S. N., Lemieux, L., Bell, G. S., Hammers, A., Sisodiya, S. M., Bartlett, P. A., Shorvon, S. D., Sander, J. W. A. S., & Duncan, J. S. (2003) · Annals of Neurology · doi:10.1002/ana.10463 · Cited by 173
When should temporal-lobe epilepsy be treated surgically?
Spencer, S. S. (2002) · The Lancet Neurology · doi:10.1016/s1474-4422(02)00163-1 · Cited by 172
Cortical activity related to accuracy of letter recognition
Garrett, A. S., Flowers, D. L., Absher, J. R., Fahey, F. H., Gage, H. D., Keyes, J. W., Porrino, L. J., & Wood, F. B. (2000) · NeuroImage · doi:10.1006/nimg.1999.0528 · Cited by 62
Metadata
- Authors
- Koepp, M.
- Venue
- Brain
- Publisher
- Oxford University Press (OUP)
- Published
- 1997-10-01
- Volume
- 120
- Issue
- 10
- Pages
- 1865-1876
- ISSN
- 0006-8950 (ISSN-L)
- 1460-2156
- OpenAlex
- W2100391054
- Cited by
- 91
- References
- 2
- FWCI
- 4.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.