The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Evidence for axonal membrane hyperpolarization in multifocal motor neuropathy with conduction block
Abstract
Multiple nerve excitability measurements were used to investigate axonal membrane properties of patients diagnosed with multifocal motor neuropathy (MMN). Six patients were selected, all with evidence of distal focal motor conduction block involving the median nerve in the forearm. In all patients, the median nerve was stimulated at the wrist, just distal to the site of block, and the resulting compound muscle action potentials were recorded from abductor pollicis brevis. Stimulus-response behaviour, the strength--duration time constant, threshold electrotonus to 100 ms polarizing currents, a current-threshold relationship and the recovery of excitability following supramaximal activation were recorded using a protocol described recently. When compared with control values, patients demonstrated significantly greater superexcitability, a 'fanning out' of threshold electrotonus recordings, and a significant change in the slope of the current--threshold relationship. These abnormalities in axonal membrane excitability parameters closely resembled those in normal axons hyperpolarized following release from ischaemia. To test for axonal hyperpolarization, DC depolarizing currents were applied to the nerves of three patients, and all the excitability parameters were normalized by depolarization. Attempts to trace excitability measures proximally towards the site of block were unsuccessful, as the nerve became inexcitable in all cases. It is suggested that the distal hyperpolarization is probably linked to focal depolarization and that the clinical features of MMN are consistent with a depolarizing/hyperpolarizing lesion.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Paraesthesiae induced by prolonged high frequency stimulation of human cutaneous afferents
Kiernan, M. C., Hales, J. P., Gracies, J., Mogyoros, I., & Burke, D. (1997) · The Journal of Physiology · doi:10.1111/j.1469-7793.1997.461bn.x · Cited by 32
Self-citation
Cited by
Minhas, P., Bansal, V., Patel, J., Ho, J. S., Diaz, J., Datta, A., & Bikson, M. (2010) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2010.05.007 · Cited by 267
Nerve excitability changes in critical illness polyneuropathy
Z'Graggen, W. J. (2006) · Brain · doi:10.1093/brain/awl191 · Cited by 255
The tibialis anterior response revisited
Lehn, A. C., Dionisio, S., Airey, C. A., Brown, H., Blum, S., & Henderson, R. (2014) · Journal of Neurology · doi:10.1007/s00415-014-7329-4 · Cited by 6
Contraction response to muscle percussion: A reappraisal of the mechanism of this bedside test
Czarnetzki, C., Truffert, A., Mekideche, A., Poncet, A., Lysakowski, C., Tramèr, M. R., & Magistris, M. R. (2018) · Clinical Neurophysiology · doi:10.1016/j.clinph.2017.10.013 · Cited by 1
Metadata
- Authors
- Kiernan, M. C., Guglielmi, J.-M., Kaji, R., Murray, N. M. F., & Bostock, H.
- Venue
- Brain
- Publisher
- Oxford University Press (OUP)
- Published
- 2002-03-01
- Volume
- 125
- Issue
- 3
- Pages
- 664-675
- ISSN
- 0006-8950 (ISSN-L)
- 1460-2156
- OpenAlex
- W2114959484
- Cited by
- 186
- References
- 1
- FWCI
- 7.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evidence for axonal membrane hyperpolarization in multifocal motor neuropathy with conduction block. https://app.cochat.ai/papers/10.1093/brain/awf041
- The paper
- Kiernan, M. C., Guglielmi, J.-M., Kaji, R., Murray, N. M. F., & Bostock, H. (2002). Evidence for axonal membrane hyperpolarization in multifocal motor neuropathy with conduction block. Brain. https://doi.org/10.1093/brain/awf041
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.