The DOI matches its Crossref record; 50 of the 50 references it cites were found in a registry or an index.
Electrocorticographic high gamma activity versus electrical cortical stimulation mapping of naming
Open accessAbstract
Subdural electrocorticographic (ECoG) recordings in patients undergoing epilepsy surgery have shown that functional activation is associated with event-related broadband gamma activity in a higher frequency range (>70 Hz) than previously studied in human scalp EEG. To investigate the utility of this high gamma activity (HGA) for mapping language cortex, we compared its neuroanatomical distribution with functional maps derived from electrical cortical stimulation (ECS), which remains the gold standard for predicting functional impairment after surgery for epilepsy, tumours or vascular malformations. Thirteen patients had undergone subdural electrode implantation for the surgical management of intractable epilepsy. Subdural ECoG signals were recorded while each patient verbally named sequentially presented line drawings of objects, and estimates of event-related HGA (80-100 Hz) were made at each recording site. Routine clinical ECS mapping used a subset of the same naming stimuli at each cortical site. If ECS disrupted mouth-related motor function, i.e. if it affected the mouth, lips or tongue, naming could not be tested with ECS at the same cortical site. Because naming during ECoG involved these muscles of articulation, the sensitivity and specificity of ECoG HGA were estimated relative to both ECS-induced impairments of naming and ECS disruption of mouth-related motor function. When these estimates were made separately for 12 electrode sites per patient (the average number with significant HGA), the specificity of ECoG HGA with respect to ECS was 78% for naming and 81% for mouth-related motor function, and equivalent sensitivities were 38% and 46%, respectively. When ECS maps of naming and mouth-related motor function were combined, the specificity and sensitivity of ECoG HGA with respect to ECS were 84% and 43%, respectively. This study indicates that event-related ECoG HGA during confrontation naming predicts ECS interference with naming and mouth-related motor function with good specificity but relatively low sensitivity. Its favourable specificity suggests that ECoG HGA can be used to construct a preliminary functional map that may help identify cortical sites of lower priority for ECS mapping. Passive recordings of ECoG gamma activity may be done simultaneously at all electrode sites without the risk of after-discharges associated with ECS mapping, which must be done sequentially at pairs of electrodes. We discuss the relative merits of these two functional mapping techniques.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Event-related EEG/MEG synchronization and desynchronization: basic principles
Pfurtscheller, G., & Lopes da Silva, F. H. (1999) · Clinical Neurophysiology · doi:10.1016/s1388-2457(99)00141-8 · Cited by 7,328
Kaplan, E., Goodglass, H., Weıntraub, S., & Segal, O. (2001) · Medical Entomology and Zoology · Cited by 4,378
Visual Feature Integration and the Temporal Correlation Hypothesis
Singer, W., & Gray, C. M. (1995) · Annual Review of Neuroscience · doi:10.1146/annurev.ne.18.030195.003011 · Cited by 3,123
Oscillatory gamma activity in humans and its role in object representation
Tallon-Baudry, C. (1999) · Trends in Cognitive Sciences · doi:10.1016/s1364-6613(99)01299-1 · Cited by 2,129
Ojemann, G., Ojemann, J., Lettich, E., & Berger, M. (1989) · Journal of Neurosurgery · doi:10.3171/jns.1989.71.3.0316 · Cited by 1,489
Tombaugh, T. (1999) · Archives of Clinical Neuropsychology · doi:10.1016/s0887-6177(97)00095-4 · Cited by 1,439
Temporal binding and the neural correlates of sensory awareness.
Engel, A. K., & Singer, W. (2001) · Trends in Cognitive Sciences · doi:10.1016/s1364-6613(00)01568-0 · Cited by 1,372
A brain–computer interface using electrocorticographic signals in humans
Leuthardt, E. C., Schalk, G., Wolpaw, J. R., Ojemann, J. G., & Moran, D. W. (2004) · Journal of Neural Engineering · doi:10.1088/1741-2560/1/2/001 · Cited by 1,188
Crone, N. (1998) · Brain · doi:10.1093/brain/121.12.2301 · Cited by 1,044
Self-citationCrone, N. (1998) · Brain · doi:10.1093/brain/121.12.2271 · Cited by 942
Self-citation
Cited by
High-Frequency Brain Activity and Muscle Artifacts in MEG/EEG: A Review and Recommendations
Muthukumaraswamy, S. D. (2013) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2013.00138 · Cited by 697
High-frequency gamma oscillations and human brain mapping with electrocorticography
Crone, N. E., Sinai, A., & Korzeniewska, A. (2006) · Progress in Brain Research · doi:10.1016/s0079-6123(06)59019-3 · Cited by 526
Self-citationLachaux, J.-P., Axmacher, N., Mormann, F., Halgren, E., & Crone, N. E. (2012) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2012.06.008 · Cited by 506
Self-citationTwo-dimensional movement control using electrocorticographic signals in humans
Schalk, G., Miller, K. J., Anderson, N. R., Wilson, J. A., Smyth, M. D., Ojemann, J. G., Moran, D. W., Wolpaw, J. R., & Leuthardt, E. C. (2008) · Journal of Neural Engineering · doi:10.1088/1741-2560/5/1/008 · Cited by 482
Brain-Computer Interfaces Using Electrocorticographic Signals
Schalk, G., & Leuthardt, E. C. (2011) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2011.2172408 · Cited by 427
Signal quality of simultaneously recorded invasive and non-invasive EEG
Ball, T., Kern, M., Mutschler, I., Aertsen, A., & Schulze-Bonhage, A. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.02.028 · Cited by 403
Clinical applications of the functional connectome
Castellanos, F. X., Di Martino, A., Craddock, R. C., Mehta, A. D., & Milham, M. P. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.04.083 · Cited by 312
Advanced Neurotechnologies for Chronic Neural Interfaces: New Horizons and Clinical Opportunities
Kipke, D. R., Shain, W., Buzsáki, G., Fetz, E., Henderson, J. M., Hetke, J. F., & Schalk, G. (2008) · The Journal of Neuroscience · doi:10.1523/jneurosci.3879-08.2008 · Cited by 286
Movement related activity in the high gamma range of the human EEG
Ball, T., Demandt, E., Mutschler, I., Neitzel, E., Mehring, C., Vogt, K., Aertsen, A., & Schulze-Bonhage, A. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2008.02.032 · Cited by 274
Automated electrocorticographic electrode localization on individually rendered brain surfaces
Hermes, D., Miller, K. J., Noordmans, H. J., Vansteensel, M. J., & Ramsey, N. F. (2010) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2009.10.005 · Cited by 262
High-frequency gamma activity (80–150 Hz) is increased in human cortex during selective attention
Ray, S., Niebur, E., Hsiao, S. S., Sinai, A., & Crone, N. E. (2008) · Clinical Neurophysiology · doi:10.1016/j.clinph.2007.09.136 · Cited by 257
Self-citationPei, X., Barbour, D. L., Leuthardt, E. C., & Schalk, G. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/4/046028 · Cited by 237
Cortical gamma responses: Searching high and low
Crone, N. E., Korzeniewska, A., & Franaszczuk, P. J. (2011) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2010.10.013 · Cited by 201
Self-citationPei, X., Leuthardt, E. C., Gaona, C. M., Brunner, P., Wolpaw, J. R., & Schalk, G. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.10.029 · Cited by 204
Kern, M., Aertsen, A., Schulze-Bonhage, A., & Ball, T. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.042 · Cited by 153
“Yet, at the same time, many previous ECoG studies rely on time–frequency representations of ECoG activity (Ball et al., 2008; Crone et al., 1998a,b, 2006; Lachaux et al., 2005; Pistohl et al., 2012; Schalk et al., 2008; Sinai et al., 2005).”
High-density mapping of primate digit representations with a 1152-channel µECoG array
Kaiju, T., Inoue, M., Hirata, M., & Suzuki, T. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abe245 · Cited by 42
“Generally, when mapping the brain activity using ECoG signals, the increase in power at a high frequency called a highgamma band (or broadband gamma) is often used as an indicator of cortical activity [33].”
MethodElectrocorticography and functional mapping
(2019) · Handbook of Clinical Neurology · doi:10.1016/b978-0-444-64032-1.00020-5 · Cited by 28
Wilmskoetter, J., Del Gaizo, J., Phillip, L., Behroozmand, R., Gleichgerrcht, E., Fridriksson, J., Riley, E., & Bonilha, L. (2019) · Clinical Neurophysiology · doi:10.1016/j.clinph.2019.08.011 · Cited by 9
Metadata
- Authors
- Sinai, A., Bowers, C. W., Crainiceanu, C. M., Boatman, D., Gordon, B., Lesser, R. P., Lenz, F. A., & Crone, N. E.
- Venue
- Brain
- Publisher
- Oxford University Press (OUP)
- Published
- 2005-04-07
- Volume
- 128
- Issue
- 7
- Pages
- 1556-1570
- ISSN
- 0006-8950 (ISSN-L)
- 1460-2156
- OpenAlex
- W2112585267
- Cited by
- 266
- References
- 50
- FWCI
- 5.91
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.