Treatment of Vacutainers for Use in the Analysis of Volatile Organic Compounds in Human Blood at the Low Parts-Per-Tri11ion Level
The DOI matches its Crossref record.
Abstract
Vacutainers that are routinely used for blood collection contain significant amounts of volatile organic compounds (VOCs). These VOCs interfere with the low parts-per-trillion analysis of VOCs in whole blood either by causing false positives or by masking the presence of VOCs because of high background levels. Benzene, bromoform, ethylbenzene, m/p-xylene, o-xylene, styrene, and various hydrocarbons are the most significant sources of VOC contamination present in the vacutainers. A method of removing VOCs from 10-mL gray-top vacutainers is presented. This method uses a combination of heat and vacuum to reduce the VOCs to levels compatible with low parts-per-trillion analysis of VOCs in whole blood.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Nuckols, J. R., Ashley, D. L., Lyu, C., Gordon, S. M., Hinckley, A. F., & Singer, P. (2005) · Environmental Health Perspectives · doi:10.1289/ehp.7141 · Cited by 120
Self-citationDisposition of Bromodichloromethane in Humans Following Oral and Dermal Exposure
Leavens, T. L., Blount, B. C., DeMarini, D. M., Madden, M. C., Valentine, J. L., Case, M. W., Silva, L. K., Warren, S. H., Hanley, N. M., & Pegram, R. A. (2007) · Toxicological Sciences · doi:10.1093/toxsci/kfm190 · Cited by 82
“Whole blood was collected from the unexposed arm through an iv cannula in the antecubital vein into fluoride/ oxalate gray-top vacutainer tubes (Becton Dickinson, Franklin Lakes, NJ) that were pretreated to remove volatile organic contaminants (Cardinali et al., 1995).”
MethodComparison of Trihalomethanes in Tap Water and Blood: A Case Study in the United States
Rivera-Núñez, Z., Wright, J. M., Blount, B. C., Silva, L. K., Jones, E., Chan, R. L., Pegram, R. A., Singer, P. C., & Savitz, D. A. (2012) · Environmental Health Perspectives · doi:10.1289/ehp.1104347 · Cited by 65
Ashley, D. L., Blount, B. C., Singer, P. C., Depaz, E., Wilkes, C., Gordon, S., Lyu, C., & Masters, J. (2005) · Archives of Environmental & Occupational Health · doi:10.3200/aeoh.60.1.7-15 · Cited by 60
Self-citation
Metadata
- Authors
- Cardinali, F. L., McCraw, J. M., Ashley, D. L., Bonin, M., & Wooten, J.
- Venue
- Journal of Chromatographic Science
- Publisher
- Oxford University Press (OUP)
- Published
- 1995-10-01
- Volume
- 33
- Issue
- 10
- Pages
- 557-560
- ISSN
- 0021-9665 (ISSN-L)
- 1945-239X
- OpenAlex
- W2075287089
- Cited by
- 41
- References
- 0
- FWCI
- 0.82
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Treatment of Vacutainers for Use in the Analysis of Volatile Organic Compounds in Human Blood at the Low Parts-Per-Tri11ion Level. https://app.cochat.ai/papers/10.1093/chromsci/33.10.557
- The paper
- Cardinali, F. L., McCraw, J. M., Ashley, D. L., Bonin, M., & Wooten, J. (1995). Treatment of Vacutainers for Use in the Analysis of Volatile Organic Compounds in Human Blood at the Low Parts-Per-Tri11ion Level. Journal of Chromatographic Science. https://doi.org/10.1093/chromsci/33.10.557
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.