The Infectious Diseases Society of America Guidelines on the Diagnosis of COVID-19: Antigen Testing (June 2021)

Hanson, Kimberly E, Altayar, Osama, Caliendo, Angela M, Arias, Cesar A, Englund, Janet A, Hayden, Mary K, Lee, Mark J, Loeb, Mark, Patel, Robin, El Alayli, Abdallah, Sultan, Shahnaz, Falck-Ytter, Yngve, Lavergne, Valery, Mansour, Razan, Morgan, Rebecca L, Murad, M Hassan, Patel, Payal, Bhimraj, Adarsh, Mustafa, Reem A · 2024 · Clinical Infectious Diseases
Cited by 55

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

Immunoassays designed to detect SARS-CoV-2 protein antigens are now commercially available. The most widely used tests are rapid lateral flow assays that generate results in ~15 minutes for diagnosis at the point-of-care. Higher throughput, laboratory-based SARS-CoV-2 antigen (Ag) assays have also been developed. The overall accuracy of SARS-CoV-2 Ag tests, however, is not well defined. The Infectious Diseases Society of America (IDSA) convened an expert panel to perform a systematic review of the literature and develop best-practice guidance related to SARS-CoV-2 Ag testing. This guideline is the third in a series of rapid, frequently updated COVID-19 diagnostic guidelines developed by IDSA. IDSA’s goal was to develop evidence-based recommendations or suggestions that assist clinicians, clinical laboratories, patients, public health authorities, administrators, and policymakers in decisions related to the optimal use of SARS-CoV-2 Ag tests in both medical and nonmedical settings. A multidisciplinary panel of infectious diseases clinicians, clinical microbiologists, and experts in systematic literature review identified and prioritized clinical questions related to the use of SARS-CoV-2 Ag tests. Grading of Recommendations Assessment, Development, and Evaluation (GRADE) methodology was used to assess the certainty of evidence and make testing recommendations. The panel agreed on 5 diagnostic recommendations. These recommendations address Ag testing in symptomatic and asymptomatic individuals as well as assess single versus repeat testing strategies. Data on the clinical performance of US Food and Drug Administration SARS-CoV-2 Ag tests with Emergency Use Authorization are mostly limited to single, one-time testing versus standard nucleic acid amplification testing (NAAT) as the reference standard. Rapid Ag tests have high specificity and low to modest sensitivity compared with reference NAAT methods. Antigen test sensitivity is heavily dependent on viral load, with differences observed between symptomatic compared with asymptomatic individuals and the time of testing post-onset of symptoms. Based on these observations, rapid reverse transcriptase–polymerase chain reaction (RT-PCR) or laboratory-based NAAT remain the diagnostic methods of choice for diagnosing SARS-CoV-2 infection. However, when molecular testing is not readily available or is logistically infeasible, Ag testing can help identify some individuals with SARS-CoV-2 infection. The overall quality of available evidence supporting use of Ag testing was graded as very low to moderate.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/cid/ciab557

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 55

Metadata

Authors
Hanson, K. E., Altayar, O., Caliendo, A. M., Arias, C. A., Englund, J. A., Hayden, M. K., Lee, M. J., Loeb, M., Patel, R., El Alayli, A., Sultan, S., Falck-Ytter, Y., Lavergne, V., Mansour, R., Morgan, R. L., Murad, M. H., Patel, P., Bhimraj, A., & Mustafa, R. A.
Venue
Clinical Infectious Diseases
Published
2021-06-23
Volume
78
Issue
7
Pages
e208-e229
ISSN
  • 1058-4838 (ISSN-L)
  • 1537-6591
OpenAlex
W3173937832
Cited by
55
References
8
FWCI
3.85
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.