A Dual Point-of-Care Test Shows Good Performance in Simultaneously Detecting Nontreponemal and Treponemal Antibodies in Patients With Syphilis: A Multisite Evaluation Study in China

Open access
Yin, Yue-Ping, Chen, Xiang-Sheng, Wei, Wan-Hui, Gong, Kuang-Long, Cao, Wen-Ling, Yong, Gang, Feng, Liang, Huang, Shu-Jie, Wang, Dong-Mei, Han, Yan, Chen, Shao-Chun, Mabey, David, Peeling, Rosanna W. · 2013 · Clinical Infectious Diseases
Cited by 95

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Rapid point-of-care (POC) syphilis tests based on simultaneous detection of treponemal and nontreponemal antibodies (dual POC tests) offer the opportunity to increase coverage of syphilis screening and treatment. This study aimed to conduct a multisite performance evaluation of a dual POC syphilis test in China. METHODS: Participants were recruited from patients at sexually transmitted infection clinics and high-risk groups in outreach settings in 6 sites in China. Three kinds of specimens (whole blood [WB], fingerprick blood [FB], and blood plasma [BP]) were used for evaluating sensitivity and specificity of the Dual Path Platform (DPP) Syphilis Screen and Confirm test using its treponemal and nontreponemal lines to compare Treponema pallidum particle agglutination (TPPA) assay and toluidine red unheated serum test (TRUST) as reference standards. RESULTS: A total of 3134 specimens (WB 1323, FB 488, and BP 1323) from 1323 individuals were collected. The sensitivities as compared with TPPA were 96.7% for WB, 96.4% for FB, and 94.6% for BP, and the specificities were 99.3%, 99.1%, and 99.6%, respectively. The sensitivities as compared with TRUST were 87.2% for WB, 85.8% for FB, and 88.4% for BP, and the specificities were 94.4%, 96.1%, and 95.0%, respectively. For specimens with a TRUST titer of 1:4 or higher, the sensitivities were 100.0% for WB, 97.8% for FB, and 99.6% for BP. CONCLUSIONS: DPP test shows good sensitivity and specificity in detecting treponemal and nontreponemal antibodies in 3 kinds of specimens. It is hoped that this assay can be considered as an alternative in the diagnosis of syphilis, particularly in resource-limited areas.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/cid/cis928

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 95

Metadata

Authors
Yin, Y.-P., Chen, X.-S., Wei, W.-H., Gong, K.-L., Cao, W.-L., Yong, G., Feng, L., Huang, S.-J., Wang, D.-M., Han, Y., Chen, S.-C., Mabey, D., & Peeling, R. W.
Venue
Clinical Infectious Diseases
Published
2012-11-02
Volume
56
Issue
5
Pages
659-665
ISSN
  • 1058-4838 (ISSN-L)
  • 1537-6591
OpenAlex
W2101088631
Cited by
95
References
2
FWCI
7.36
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Dual Point-of-Care Test Shows Good Performance in Simultaneously Detecting Nontreponemal and Treponemal Antibodies in Patients With Syphilis: A Multisite Evaluation Study in China. https://app.cochat.ai/papers/10.1093/cid/cis928
The paper
Yin, Y.-P., Chen, X.-S., Wei, W.-H., Gong, K.-L., Cao, W.-L., Yong, G., Feng, L., Huang, S.-J., Wang, D.-M., Han, Y., Chen, S.-C., Mabey, D., & Peeling, R. W. (2013). A Dual Point-of-Care Test Shows Good Performance in Simultaneously Detecting Nontreponemal and Treponemal Antibodies in Patients With Syphilis: A Multisite Evaluation Study in China. Clinical Infectious Diseases. https://doi.org/10.1093/cid/cis928

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.