A New and Rapid Method for the Determination of Glucose by Measurement of Rate of Oxygen Consumption
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Glucose levels in serum, plasma, and urine are determined rapidly and conveniently by a new glucose oxidase method employing a polarographic oxygen sensor with a circuit modified to record the rate of oxygen consumption. The maximum apparent rate of oxygen consumption relative to the rate obtained with a glucose standard provides a direct measure of the glucose level in the sample; results are obtainable within 20 sec. after sample (100 µl.) addition and within 3 min. after a blood sample is withdrawn from a patient. Interferences associated with prior colorimetric glucose oxidase methods are avoided by measuring oxygen consumption instead of hydrogen peroxide formation. The method is described and results are presented showing a standard deviation of less than 1.5% on replicate determinations and a bias of 1% with respect to data obtained on the same samples by the automated ferricyanide method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kinetics and Mechanism of Action of Glucose Oxidase
Gibson, Q. H., Swoboda, B. E. P., & Massey, V. (1964) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)91224-x · Cited by 536
Specificity of glucose oxidase (notatin)
Keilin, D., & Hartree, E. F. (1952) · Biochemical Journal · doi:10.1042/bj0500331 · Cited by 201
A Methodological Study of the Enzymatic Determination of Glucose in Blood
Hjelm, M., & Verdier, C. H. D. (1963) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.3109/00365516309079764 · Cited by 190
Cited by
Electrochemical Glucose Sensors and Their Applications in Diabetes Management
Heller, A., & Feldman, B. (2008) · Chemical Reviews · doi:10.1021/cr068069y · Cited by 1,707
Martin, B. C., Warram, J. H., Krolewski, A. S., Soeldner, J. S., Kahn, C. R., Martin, B. C., & Bergman, R. N. (1992) · The Lancet · doi:10.1016/0140-6736(92)92814-v · Cited by 1,158
Seppala-Lindroos, A. (2002) · Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.87.7.3023 · Cited by 168
Warram, J. H., Martin, B. C., Krolewski, A. S., Soeldner, J. S., & Kahn, C. R. (1990) · Annals of Internal Medicine · doi:10.7326/0003-4819-113-12-909 · Cited by 1,038
Use of metabolic markers to identify overweight individuals who are insulin resistant
McLaughlin, T., Abbasi, F., Cheal, K., Chu, J., Lamendola, C., & Reaven, G. (2003) · Annals of Internal Medicine · doi:10.7326/0003-4819-139-10-200311180-00007 · Cited by 1,022
“Blood samples were obtained before the insulin suppression test to measure plasma glucose (30), insulin (31), and lipid and lipoprotein (32–34) levels by methods that were identical during the period of study.”
Method
Metadata
- Authors
- Kadish, A. H., Litle, R. L., & Sternberg, J. C.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1968-02-01
- Volume
- 14
- Issue
- 2
- Pages
- 116-131
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2112538182
- Cited by
- 740
- References
- 3
- FWCI
- 9.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.