A New and Rapid Method for the Determination of Glucose by Measurement of Rate of Oxygen Consumption
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Glucose levels in serum, plasma, and urine are determined rapidly and conveniently by a new glucose oxidase method employing a polarographic oxygen sensor with a circuit modified to record the rate of oxygen consumption. The maximum apparent rate of oxygen consumption relative to the rate obtained with a glucose standard provides a direct measure of the glucose level in the sample; results are obtainable within 20 sec. after sample (100 µl.) addition and within 3 min. after a blood sample is withdrawn from a patient. Interferences associated with prior colorimetric glucose oxidase methods are avoided by measuring oxygen consumption instead of hydrogen peroxide formation. The method is described and results are presented showing a standard deviation of less than 1.5% on replicate determinations and a bias of 1% with respect to data obtained on the same samples by the automated ferricyanide method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kinetics and Mechanism of Action of Glucose Oxidase
Gibson, Q. H., Swoboda, B. E. P., & Massey, V. (1964) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)91224-x · Cited by 536
Specificity of glucose oxidase (notatin)
Keilin, D., & Hartree, E. F. (1952) · Biochemical Journal · doi:10.1042/bj0500331 · Cited by 201
A Methodological Study of the Enzymatic Determination of Glucose in Blood
Hjelm, M., & Verdier, C. H. D. (1963) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.3109/00365516309079764 · Cited by 190
Cited by
Electrochemical Glucose Sensors and Their Applications in Diabetes Management
Heller, A., & Feldman, B. (2008) · Chemical Reviews · doi:10.1021/cr068069y · Cited by 1,707
Martin, B. C., Warram, J. H., Krolewski, A. S., Soeldner, J. S., Kahn, C. R., Martin, B. C., & Bergman, R. N. (1992) · The Lancet · doi:10.1016/0140-6736(92)92814-v · Cited by 1,158
Seppala-Lindroos, A. (2002) · Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.87.7.3023 · Cited by 168
Warram, J. H., Martin, B. C., Krolewski, A. S., Soeldner, J. S., & Kahn, C. R. (1990) · Annals of Internal Medicine · doi:10.7326/0003-4819-113-12-909 · Cited by 1,038
Use of metabolic markers to identify overweight individuals who are insulin resistant
McLaughlin, T., Abbasi, F., Cheal, K., Chu, J., Lamendola, C., & Reaven, G. (2003) · Annals of Internal Medicine · doi:10.7326/0003-4819-139-10-200311180-00007 · Cited by 1,022
“Blood samples were obtained before the insulin suppression test to measure plasma glucose (30), insulin (31), and lipid and lipoprotein (32–34) levels by methods that were identical during the period of study.”
MethodFructose-induced insulin resistance and hypertension in rats.
Hwang, I. S., Ho, H., Hoffman, B. B., & Reaven, G. M. (1987) · Hypertension · doi:10.1161/01.hyp.10.5.512 · Cited by 889
Facchini, F. (1991) · JAMA · doi:10.1001/jama.1991.03470210076036 · Cited by 885
Zavaroni, I., Bonora, E., Pagliara, M., Dall'Aglio, E., Luchetti, L., Buonanno, G., Bonati, P. A., Bergonzani, M., Gnudi, L., Passeri, M., et al. (1989) · New England Journal of Medicine · doi:10.1056/nejm198903163201105 · Cited by 771
Reaven, G. M., Chen, Y. D., Jeppesen, J., Maheux, P., & Krauss, R. M. (1993) · Journal of Clinical Investigation · doi:10.1172/jci116541 · Cited by 690
Lin, K. Y., Ito, A., Asagami, T., Tsao, P. S., Adimoolam, S., Kimoto, M., Tsuji, H., Reaven, G. M., & Cooke, J. P. (2002) · Circulation · doi:10.1161/01.cir.0000027109.14149.67 · Cited by 651
An enzyme electrode for the amperometric determination of glucose
Guilbault, G. G., & Lubrano, G. J. (1973) · Analytica Chimica Acta · doi:10.1016/s0003-2670(01)82476-4 · Cited by 571
Ho, K. Y., Veldhuis, J. D., Johnson, M. L., Furlanetto, R., Evans, W. S., Alberti, K. G., & Thorner, M. O. (1988) · Journal of Clinical Investigation · doi:10.1172/jci113450 · Cited by 503
“Blood glucose was measured using the glucose oxidase method and a glucose analyzer (Beckman Instruments, Fullerton, CA) (15).”
MethodLiver Fat in the Metabolic Syndrome
Kotronen, A., Westerbacka, J., Bergholm, R., Pietiläinen, K. H., & Yki-Järvinen, H. (2007) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2007-0482 · Cited by 457
Ryysy, L., Häkkinen, A. M., Goto, T., Vehkavaara, S., Westerbacka, J., Halavaara, J., & Yki-Järvinen, H. (2000) · Diabetes · doi:10.2337/diabetes.49.5.749 · Cited by 431
“sured in duplicate with the glucose oxidase method (24) using a Glucose”
MethodPietiläinen, K. H., Sysi-Aho, M., Rissanen, A., Seppänen-Laakso, T., Yki-Järvinen, H., Kaprio, J., & Orešič, M. (2007) · PLoS ONE · doi:10.1371/journal.pone.0000218 · Cited by 418
Lipid peroxidation and activity of antioxidant enzymes in diabetic rats
Kakkar, R., Kalra, J., Mantha, S. V., & Prasad, K. (1995) · Molecular and Cellular Biochemistry · doi:10.1007/bf01322333 · Cited by 395
Dietary fat content modifies liver fat in overweight nondiabetic subjects
Westerbacka, J., Lammi, K., Häkkinen, A.-M., Rissanen, A., Salminen, I., Aro, A., & Yki-Järvinen, H. (2005) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2004-1983 · Cited by 379
“Plasma glucose concentrations were measured in duplicate with the glucose oxidase method using a Beckman Glucose Analyzer II (Beckman Instruments, Fullerton, CA) (26).”
MethodResistance to Insulin-Mediated Glucose Disposal as a Predictor of Cardiovascular Disease
Yip, J. (1998) · Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.83.8.2773 · Cited by 360
Westerbacka, J., Corn�r, A., Tiikkainen, M., Tamminen, M., Vehkavaara, S., H�kkinen, A.-M., Fredriksson, J., & Yki-J�rvinen, H. (2004) · Diabetologia · doi:10.1007/s00125-004-1460-1 · Cited by 338
Panahi, Y., Hosseini, M. S., Khalili, N., Naimi, E., Simental-Mendía, L. E., Majeed, M., & Sahebkar, A. (2016) · Biomedicine & Pharmacotherapy · doi:10.1016/j.biopha.2016.05.037 · Cited by 328
REAVEN, G. M., CHEN, Y.-D. I., GOLAY, A., SWISLOCKI, A. L. M., & JASPAN, J. B. (1987) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem-64-1-106 · Cited by 326
Defective regulation of triglyceride metabolism by insulin in the liver in NIDDM.
Malmström, R., Packard, C. J., Caslake, M., Bedford, D., Stewart, P., Yki-Järvinen, H., Shepherd, J., & Taskinen, M.-R. (1997) · Diabetologia · doi:10.1007/s001250050700 · Cited by 319
Glucose-free fatty acid cycle operates in human heart and skeletal muscle in vivo.
Nuutila, P., Koivisto, V. A., Knuuti, J., Ruotsalainen, U., Teräs, M., Haaparanta, M., Bergman, J., Solin, O., Voipio-Pulkki, L. M., & Wegelius, U. (1992) · Journal of Clinical Investigation · doi:10.1172/jci115780 · Cited by 313
HOLLENBECK, C., & REAVEN, G. M. (1987) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem-64-6-1169 · Cited by 307
Natural Course of Insulin Resistance in Type I Diabetes
Yki-Järvinen, H., & Koivisto, V. A. (1986) · New England Journal of Medicine · doi:10.1056/nejm198607243150404 · Cited by 304
Kakkar, R., Mantha, S. V., Radhi, J., Prasad, K., & Kalra, J. (1998) · Clinical Science · doi:10.1042/cs0940623 · Cited by 303
LAWS, A., & REAVEN, G. M. (1992) · Journal of Internal Medicine · doi:10.1111/j.1365-2796.1992.tb00494.x · Cited by 291
Kinetics of glucose disposal in whole body and across the forearm in man.
Yki-Järvinen, H., Young, A. A., Lamkin, C., & Foley, J. E. (1987) · Journal of Clinical Investigation · doi:10.1172/jci113011 · Cited by 265
Virkamäki, A., Korsheninnikova, E., Seppälä-Lindroos, A., Vehkavaara, S., Goto, T., Halavaara, J., Häkkinen, A.-M., & Yki-Järvinen, H. (2001) · Diabetes · doi:10.2337/diabetes.50.10.2337 · Cited by 260
Effect of fructose feeding on insulin secretion and insulin action in the rat
Zavaroni, I., Sander, S., Scott, S., & Reaven, G. M. (1980) · Metabolism · doi:10.1016/0026-0495(80)90041-4 · Cited by 254
Kashiwagi, A., Verso, M. A., Andrews, J., Vasquez, B., Reaven, G., & Foley, J. E. (1983) · Journal of Clinical Investigation · doi:10.1172/jci111080 · Cited by 250
Anderson, J. W., Allgood, L. D., Turner, J., Oeltgen, P. R., & Daggy, B. P. (1999) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/70.4.466 · Cited by 247
“Serum glucose concentrations were measured by using glucose oxidase (22).”
MethodTobey, T. A., Greenfield, M., Kraemer, F., & Reaven, G. M. (1981) · Metabolism · doi:10.1016/0026-0495(81)90167-0 · Cited by 243
Jeppesen, J., Schaaf, P., Jones, C., Zhou, M., Chen, Y., & Reaven, G. (1997) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/65.4.1027 · Cited by 232
Jeppesen, J., Hollenbeck, C. B., Zhou, M.-Y., Coulston, A. M., Jones, C., Chen, Y.-D. I., & Reaven, G. M. (1995) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/01.atv.15.3.320 · Cited by 236
Reaven, G. M., Chen, Y. D., Hollenbeck, C. B., Sheu, W. H., Ostrega, D., & Polonsky, K. S. (1993) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem.76.1.8421101 · Cited by 214
Leon, A., Conrad, J., Hunninghake, D., & Serfass, R. (1979) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/32.9.1776 · Cited by 212
Effect of liver fat on insulin clearance
Kotronen, A., Vehkavaara, S., Seppälä-Lindroos, A., Bergholm, R., & Yki-Järvinen, H. (2007) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00444.2007 · Cited by 202
“Plasma glucose concentrations were measured in duplicate with the glucose oxidase method using Beckman Glucose Analyzer II (Beckman Instruments, Fullerton, CA) (13).”
MethodMechanism of insulin resistance in fructose-fed rats
Tobey, T. A., Mondon, C. E., Zavaroni, I., & Reaven, G. M. (1982) · Metabolism · doi:10.1016/0026-0495(82)90100-7 · Cited by 191
Reaven, G. M., Hollenbeck, C. B., & Chen, Y.-D. I. (1989) · Diabetologia · doi:10.1007/bf00265404 · Cited by 182
“The subjects then were given a 75 g oral glucose load, and blood was drawn for measurement of plasma glucose [7] and insulin [8] concentrations 30, 60, 120, and 180 min later.”
MethodKotronen, A., Seppänen‐Laakso, T., Westerbacka, J., Kiviluoto, T., Arola, J., Ruskeepää, A., Yki‐Järvinen, H., & Orešič, M. (2010) · Obesity · doi:10.1038/oby.2009.326 · Cited by 179
“analytical procedures, measurements, and calculations Plasma glucose concentrations were measured in duplicate with the glucose oxidase method using Beckman Glucose Analyzer II (Beckman Instruments, Fullerton, CA) (25).”
MethodLapela, M., Leskinen, S., Minn, H., Lindholm, P., Klemi, P., Soderstrom, K., Bergman, J., Haaparanta, M., Ruotsalainen, U., & Solin, O. (1995) · Blood · doi:10.1182/blood.v86.9.3522.bloodjournal8693522 · Cited by 174
Prevalence of hyperinsulinaemia in patients with high blood pressure
ZAVARONI, I., MAZZA, S., DALL'AGLIO, E., GASPARINI, P., PASSERI, M., & REAVEN, G. M. (1992) · Journal of Internal Medicine · doi:10.1111/j.1365-2796.1992.tb00529.x · Cited by 172
Thompson, D. A., & Campbell, R. G. (1977) · Science · doi:10.1126/science.929188 · Cited by 170
A study of the effects of dietary gum arabic in humans
Ross, A., Eastwood, M., Brydon, W., Anderson, Jr., & Anderson, D. (1983) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/37.3.368 · Cited by 167
Utriainen, T., Malmstr�m, R., M�kimattila, S., & Yki-J�rvinen, H. (1995) · Diabetologia · doi:10.1007/bf00400724 · Cited by 158
“Analytical methods. Plasma glucose concentrations were measured in duplicate using the glucose oxidase method [ 31 ], with the Beckman Glucose Analyzer II (Beckman Instruments, Fullerton, Calif., USA).”
MethodKotronen, A., Seppälä-Lindroos, A., Bergholm, R., & Yki-Järvinen, H. (2007) · Diabetologia · doi:10.1007/s00125-007-0867-x · Cited by 126
“Analytical procedures, calculations and other measurements Plasma glucose concentrations were measured in duplicate with the glucose oxidase method using a Glucose Analyzer II (Beckman Instruments, Fullerton, CA, USA) [28].”
MethodYki-Järvinen, H., Mott, D., Young, A. A., Stone, K., & Bogardus, C. (1987) · Journal of Clinical Investigation · doi:10.1172/jci113069 · Cited by 123
Meal size and frequency: effect on the thermic effect of food
Tai, M., Castillo, P., & Pi-Sunyer, F. (1991) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/54.5.783 · Cited by 97
Gender Differences in Lipoprotein Lipase Activity after Acute Exercise
Perreault, L., Lavely, J. M., Kittelson, J. M., & Horton, T. J. (2004) · Obesity Research · doi:10.1038/oby.2004.31 · Cited by 64
McLaughlin, T. (2000) · Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.85.9.3085 · Cited by 48
Pagliassotti, M. J., Pan, D. A., Prach, P. A., Koppenhafer, T. A., Storlien, L., & Hill, J. O. (1995) · Obesity Research · doi:10.1002/j.1550-8528.1995.tb00175.x · Cited by 47
Sympathetic control of hepatic glycogenolysis during glucopenia in man
Brodows, R. G., Pi-Sunyer, F. X., & Campbell, R. G. (1975) · Metabolism · doi:10.1016/0026-0495(75)90141-9 · Cited by 45
Insulin resistance, dietary cholesterol, and cholesterol concentration in postmenopausal women
Reaven, G. M., Abbasi, F., Bernhart, S., Coulston, A., Darnell, B., Dashti, N., Kim, H.-S., Kulkarni, K., Lamendola, C., McLaughlin, T., et al. (2001) · Metabolism · doi:10.1053/meta.2001.22559 · Cited by 31
Sjöberg, S., Ahrén, B., & Bolinder, J. (2002) · Journal of Internal Medicine · doi:10.1046/j.1365-2796.2002.01043.x · Cited by 13
Reaven, G. M. (1979) · Advances in Experimental Medicine and Biology · doi:10.1007/978-1-4615-9110-8_37 · Cited by 10
Metadata
- Authors
- Kadish, A. H., Litle, R. L., & Sternberg, J. C.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1968-02-01
- Volume
- 14
- Issue
- 2
- Pages
- 116-131
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2112538182
- Cited by
- 740
- References
- 3
- FWCI
- 9.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.