CoChat

Kinetic Colorimetric Measurement of Serum Lactate Dehydrogenase Activity

Babson, Arthur L, Babson, Susan R · 1973 · Clinical Chemistry
Cited by 128

The DOI matches its Crossref record.

Abstract

A kinetic colorimetric assay procedure is described for measuring lactate dehydrogenase activity, in which the reduction of NAD is coupled to the reduction of a tetrazolium salt, 2-p-iodophenyl-3-p-nitrophenyl-5-phenyl tetrazolium chloride (INT), with phenazine methosulfate serving as an intermediate electron carrier. The molar absorptivity of the formazan of INT was found to be 19.3 x 103 at 503 nm, which provides a threefold increase in sensitivity over the ultraviolet (340 nm) kinetic assay. The results correlate well with those obtained by 340-nm kinetic methods and the procedure does not require an ultraviolet spectrophotometer. The method is simple, rapid, and does not rely on secondary enzyme standards. It requires only two reagents, which are stable.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/clinchem/19.7.766

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 128

Metadata

Authors
Babson, A. L., & Babson, S. R.
Venue
Clinical Chemistry
Published
1973-07-01
Volume
19
Issue
7
Pages
766-769
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2139679164
Cited by
128
References
0
FWCI
0.56
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Kinetic Colorimetric Measurement of Serum Lactate Dehydrogenase Activity. https://app.cochat.ai/papers/10.1093/clinchem/19.7.766
The paper
Babson, A. L., & Babson, S. R. (1973). Kinetic Colorimetric Measurement of Serum Lactate Dehydrogenase Activity. Clinical Chemistry. https://doi.org/10.1093/clinchem/19.7.766

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.