Rapid, Accurate Technique for Determination of Carbon Monoxide in Blood
Open accessThe DOI matches its Crossref record.
Abstract
We report a chromatographic technique in which a vortex method of gas extraction and a thermal conductivity detector are used to measure carbon monoxide in blood. This method has the advantages of a small sample volume (100 µl), a rapid analysis time (3 min), ease of operation, and a high correlation with results of the standard gasometric method over the entire possible range (r = 0.999). The accuracy of this method (coefficient of variation) for measuring CO in human blood samples was 1.7%. With it, dissolved CO can be accurately measured, as demonstrated by the Bunsen solubility coefficient for plasma CO by this method of 22.0 ml of CO per liter of water per atm. (101 kN/m2) at 24 °C (theoretical value: 21.8).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Expired air carbon monoxide: a simple breath test of tobacco smoke intake.
Jarvis, M. J., Russell, M. A., & Saloojee, Y. (1980) · BMJ · doi:10.1136/bmj.281.6238.484 · Cited by 372
Subnormal norepinephrine release relates to presyncope in astronauts after spaceflight
Fritsch-Yelle, J. M., Whitson, P. A., Bondar, R. L., & Brown, T. E. (1996) · Journal of Applied Physiology · doi:10.1152/jappl.1996.81.5.2134 · Cited by 238
Waters, W. W., Ziegler, M. G., & Meck, J. V. (2002) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00544.2001 · Cited by 232
Metadata
- Authors
- Dahms, T. E., & Horvath, S. M.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1974-05-01
- Volume
- 20
- Issue
- 5
- Pages
- 533-537
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W1882327227
- Cited by
- 50
- References
- 0
- FWCI
- 2.46
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Rapid, Accurate Technique for Determination of Carbon Monoxide in Blood. https://app.cochat.ai/papers/10.1093/clinchem/20.5.533
- The paper
- Dahms, T. E., & Horvath, S. M. (1974). Rapid, Accurate Technique for Determination of Carbon Monoxide in Blood. Clinical Chemistry. https://doi.org/10.1093/clinchem/20.5.533
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.