Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 312

The DOI matches its Crossref record.

Evaluation of Trinder's Glucose Oxidase Method for Measuring Glucose in Serum and Urine

Lott, John A, Turner, Kathie · 1975 · Clinical Chemistry

Abstract

Trinder's method for glucose has nearly all the attributes of an ideal automated colorimetric glucose oxidase procedure. The chemicals used in the color reaction with peroxidase are readily available, the solutions are stable and can be prepared by the user, the method is highly specific and largely free of interferences, the sensitivity can be adjusted by the user to cover a wide range of glucose concentrations, and the reagents are not hazardous. We found very good agreement between results by this method and by the hexokinase and Beckman Glucose Analyzer methods. The method has been modified and adapted to the AutoAnalyzer I and SMA 6/60 (Technicon) with manifolds that give very little interaction between specimens. A study of the method by the simplex technique revealed that the glucose oxidase activity in the reagent is the most critical variable.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/clinchem/21.12.1754

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 312

Metadata

Authors
Lott, J. A., & Turner, K.
Venue
Clinical Chemistry
Published
1975-11-01
Volume
21
Issue
12
Pages
1754-1760
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W1836660506
Cited by
312
References
0
FWCI
2.99
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Evaluation of Trinder's Glucose Oxidase Method for Measuring Glucose in Serum and Urine. https://app.cochat.ai/papers/10.1093/clinchem/21.12.1754
The paper
Lott, J. A., & Turner, K. (1975). Evaluation of Trinder's Glucose Oxidase Method for Measuring Glucose in Serum and Urine. Clinical Chemistry. https://doi.org/10.1093/clinchem/21.12.1754

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.