The DOI matches its Crossref record.
Enzymic fluorometric continuous-flow assays for blood glucose, lactate, pyruvate, alanine, glycerol, and 3-hydroxybutyrate.
Abstract
We describe enzymic fluorometric methods of automated analysis for glucose, lactate, pyruvate, 3-hydroxybutyrate, glycerol, and alanine in perchloric acid extracts of blood. Unmodified Technicon AutoAnalyzer II apparatus is used. The usual concentrations of all these metabolites can be measured in as little as 0.1 ml of blood from a fasting subject. Within-batch and between-batch coefficients of variation ranged from 0.4 to 4.4% for all metabolites except 3-hydroxybutyrate, for which CV's were higher for low concentrations. Analytical recovery of added metabolites ranged from 92 to 98%. Glucose, lactate, alanine, and 3-hydroxybutyrate are stable in perchloric acid extracts for at least 13 days at room temperature, and a year at -20 degrees C; pyruvate shows a 6--8% loss after 3 days and 52% by one year at -20 degrees C; glycerol concentrations were stable at -20 degrees C for at least 13 days. Blank fluorescence is found in perchloric acid extracts of blood, necessitating blank runs for pyruvate, 3-hydroxybutyrate, glycerol, and alanine. The systems are simple to use, relatively inexpensive to operate, and are recommended for any laboratory with high throughput of samples.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ho, K. Y., Veldhuis, J. D., Johnson, M. L., Furlanetto, R., Evans, W. S., Alberti, K. G., & Thorner, M. O. (1988) · Journal of Clinical Investigation · doi:10.1172/jci113450 · Cited by 503
Self-citationNibbling versus gorging: metabolic advantages of increased meal frequency
Jenkins, D. J. A., Wolever, T. M. S., Vuksan, V., Brighenti, F., Cunnane, S. C., Rao, A. V., Jenkins, A. L., Buckley, G., Patten, R., Singer, W., et al. (1989) · New England Journal of Medicine · doi:10.1056/nejm198910053211403 · Cited by 467
Levenhagen, D. K., Gresham, J. D., Carlson, M. G., Maron, D. J., Borel, M. J., & Flakoll, P. J. (2001) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.2001.280.6.e982 · Cited by 239
Effects of cortisol on lipolysis and regional interstitial glycerol levels in humans
Djurhuus, C. B., Gravholt, C. H., Nielsen, S., Mengel, A., Christiansen, J. S., Schmitz, O. E., & Møller, N. (2002) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00544.2001 · Cited by 219
Effects of growth hormone on insulin sensitivity and forearm metabolism in normal man
M�ller, N., Butler, P. C., Antsiferov, M. A., & Alberti, K. G. M. M. (1989) · Diabetologia · doi:10.1007/bf00505182 · Cited by 192
Self-citation
Metadata
- Authors
- Lloyd, B., Burrin, J., Smythe, P., & Alberti, K. G.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1978-10-01
- Volume
- 24
- Issue
- 10
- Pages
- 1724-1729
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W1896604741
- Cited by
- 579
- References
- 0
- FWCI
- 13.69
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Enzymic fluorometric continuous-flow assays for blood glucose, lactate, pyruvate, alanine, glycerol, and 3-hydroxybutyrate. https://app.cochat.ai/papers/10.1093/clinchem/24.10.1724
- The paper
- Lloyd, B., Burrin, J., Smythe, P., & Alberti, K. G. (1978). Enzymic fluorometric continuous-flow assays for blood glucose, lactate, pyruvate, alanine, glycerol, and 3-hydroxybutyrate. Clinical Chemistry. https://doi.org/10.1093/clinchem/24.10.1724
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.