Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 172

The DOI matches its Crossref record.

Electroimmunoassay, radioimmunoassay, and radial immunodiffusion assay evaluated for quantification of human apolipoprotein B.

Curry, M D, Gustafson, A, Alaupovic, P, McConathy, W J · 1978 · Clinical Chemistry

Abstract

We examined three immunoassay techniques for measuring apolipoprotein B in serum and major lipoprotein density fractions from normolipidemic and hyperlipoproteinemic persons, comparing values by electroimmunoassay, radioimmunoassay, and radial immunodiffusion assay with those determined gravimetrically. Electroimmunoassay is faster and simpler than radioimmunoassay, and equally precise (within- and between-assay coefficients of variation for both were 5 and 7%, respectively). All the immunoassays gave results that agreed with those by gravimetry for normolipidemic sera and the corresponding lipoprotein density fractions, but only electroimmunoassay results agreed with those by gravimetry for apolipoprotein B in lipoproteins of d less than 1.019 g/ml isolated from hypertriglyceridemic patients. Concentrations of apolipoprotein B in plasma, determined by electroimmunoassay in a population of normal persons and patients with primary hyperlipoproteinemias, were: normals, 980 +/- 200; type I, 700 +/- 160; type IIa, 2000 +/- 260; type IIb, 2180 +/- 300; type III, 1300 +/- 340; type IV, 1470 +/- 400; and type V, 1550 +/- 390 mg/liter (mean +/- SD). Lipoprotein density fractions from the hyperlipoproteinemic patients each had a characteristic distribution of free and associated forms of lipoprotein family B. The absolute concentration and distribution of apolipoprotein B between the free and associated forms of lipoprotein B may represent a useful indicator of the underlying biochemical defect(s).

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/clinchem/24.2.280

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 172

Metadata

Authors
Curry, M. D., Gustafson, A., Alaupovic, P., & McConathy, W. J.
Venue
Clinical Chemistry
Published
1978-02-01
Volume
24
Issue
2
Pages
280-286
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2109542718
Cited by
172
References
0
FWCI
8.48
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Electroimmunoassay, radioimmunoassay, and radial immunodiffusion assay evaluated for quantification of human apolipoprotein B. https://app.cochat.ai/papers/10.1093/clinchem/24.2.280
The paper
Curry, M. D., Gustafson, A., Alaupovic, P., & McConathy, W. J. (1978). Electroimmunoassay, radioimmunoassay, and radial immunodiffusion assay evaluated for quantification of human apolipoprotein B. Clinical Chemistry. https://doi.org/10.1093/clinchem/24.2.280

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.