The DOI matches its Crossref record.
Electroimmunoassay, radioimmunoassay, and radial immunodiffusion assay evaluated for quantification of human apolipoprotein B.
Abstract
We examined three immunoassay techniques for measuring apolipoprotein B in serum and major lipoprotein density fractions from normolipidemic and hyperlipoproteinemic persons, comparing values by electroimmunoassay, radioimmunoassay, and radial immunodiffusion assay with those determined gravimetrically. Electroimmunoassay is faster and simpler than radioimmunoassay, and equally precise (within- and between-assay coefficients of variation for both were 5 and 7%, respectively). All the immunoassays gave results that agreed with those by gravimetry for normolipidemic sera and the corresponding lipoprotein density fractions, but only electroimmunoassay results agreed with those by gravimetry for apolipoprotein B in lipoproteins of d less than 1.019 g/ml isolated from hypertriglyceridemic patients. Concentrations of apolipoprotein B in plasma, determined by electroimmunoassay in a population of normal persons and patients with primary hyperlipoproteinemias, were: normals, 980 +/- 200; type I, 700 +/- 160; type IIa, 2000 +/- 260; type IIb, 2180 +/- 300; type III, 1300 +/- 340; type IV, 1470 +/- 400; and type V, 1550 +/- 390 mg/liter (mean +/- SD). Lipoprotein density fractions from the hyperlipoproteinemic patients each had a characteristic distribution of free and associated forms of lipoprotein family B. The absolute concentration and distribution of apolipoprotein B between the free and associated forms of lipoprotein B may represent a useful indicator of the underlying biochemical defect(s).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Modulation of lipoprotein lipase activity by apolipoproteins. Effect of apolipoprotein C-III.
Wang, C. S., McConathy, W. J., Kloer, H. U., & Alaupovic, P. (1985) · Journal of Clinical Investigation · doi:10.1172/jci111711 · Cited by 414
Self-citationLipoprotein abnormalities associated with a familial deficiency of hepatic lipase
BRECKENRIDGE, W., LITTLE, J., ALAUPOVIC, P., WANG, C., KUKSIS, A., KAKIS, G., LINDGREN, F., & GARDINER, G. (1982) · Atherosclerosis · doi:10.1016/0021-9150(82)90136-8 · Cited by 328
Self-citationHodis, H. N., Mack, W. J., Azen, S. P., Alaupovic, P., Pogoda, J. M., LaBree, L., Hemphill, L. C., Kramsch, D. M., & Blankenhorn, D. H. (1994) · Circulation · doi:10.1161/01.cir.90.1.42 · Cited by 321
Self-citationFamilial Deficiency of Apolipoproteins A-I and C-III and Precocious Coronary-Artery Disease
Norum, R. A., Lakier, J. B., Goldstein, S., Angel, A., Goldberg, R. B., Block, W. D., Noffze, D. K., Dolphin, P. J., Edelglass, J., Bogorad, D. D., et al. (1982) · New England Journal of Medicine · doi:10.1056/nejm198206243062503 · Cited by 304
Self-citationBlankenhorn, D. H., Alaupovic, P., Wickham, E., Chin, H. P., & Azen, S. P. (1990) · Circulation · doi:10.1161/01.cir.81.2.470 · Cited by 278
Self-citation
Metadata
- Authors
- Curry, M. D., Gustafson, A., Alaupovic, P., & McConathy, W. J.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1978-02-01
- Volume
- 24
- Issue
- 2
- Pages
- 280-286
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2109542718
- Cited by
- 172
- References
- 0
- FWCI
- 8.48
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electroimmunoassay, radioimmunoassay, and radial immunodiffusion assay evaluated for quantification of human apolipoprotein B. https://app.cochat.ai/papers/10.1093/clinchem/24.2.280
- The paper
- Curry, M. D., Gustafson, A., Alaupovic, P., & McConathy, W. J. (1978). Electroimmunoassay, radioimmunoassay, and radial immunodiffusion assay evaluated for quantification of human apolipoprotein B. Clinical Chemistry. https://doi.org/10.1093/clinchem/24.2.280
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.