Gel isoelectric focusing method for specific diagnosis of familial hyperlipoproteinemia type 3

Warnick, G R, Mayfield, C, Albers, J J, Hazzard, W R·1979·Clinical Chemistry

Abstract

We describe a gel isoelectric focusing procedure for resolving into at least five bands the arginine-rich protein of very-low-density lipoproteins, and use the method in diagnosis of hyperlipoproteinemia type 3. We find that deficiency of one band, designated E3, relative to E2, expressed as an E3/E2 ratio less than or equal to 0.3, is specifically associated with hyperlipoproteinemia type 3 as diagnosed by traditional criteria in a large family study. In addition, we used the procedure to test 47 referral samples with demonstrable beta-migrating very-low-density liproprotein grouped by very-low-density lipoprotein cholesterol/total triglyceride ratios of greater than or equal to 0.3, from 0.25 to 0.3, and less than 0.25. All 24 of the first group, three of six in the second, and only one of 17 in the third had E3/E2 ratios of less than or equal to 0.3. Also, two normolipidemic children, without detectable lipoprotein abnormalities but related to subjects with hyperlipoproteinemia type 3, had E3/E2 ratios of less than or equal to 0.3. Use of our procedure improves the specificity of diagnosis and allows sensitive detection of asymptomatic subjects who may be at risk of developing the disorder.

Overview

Integrity signals

Registry

Crossref · 10.1093/clinchem/25.2.279

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cited by

Sorted by citations

Metadata

Authors
Warnick, G. R., Mayfield, C., Albers, J. J., & Hazzard, W. R.
Venue
Clinical Chemistry
Published
1979-02-01
Volume
25
Issue
2
Pages
279-284
ISSN
  • 0009-9147
  • 1530-8561
Cited by
182
References
0
Language
en

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review