Comparison of current methods for high-density lipoprotein cholesterol quantitation.
The DOI matches its Crossref record.
Abstract
We compared six precipitation methods for high-density-lipoprotein cholesterol quantitation with an ultracentrifugation method, the accuracy of which was improved by correcting for 4% manipulative loss in the d greater than 1.063 fractions. For purposes of comparison, the apoprotein B-associated cholesterol (average 56 mg/L) measured by immunoassay in the d greater than 1.063 fractions was subtracted. In 65 plasma samples from men, women, and children, a heparin-Mn2+ procedure with Mn2+ at 46 mmol/L produced results slightly higher (+16 mg/L), while results with Mn2+ at 92 mmol/L averaged slightly lower (-8 mg/L) than the comparison ultracentrifuge method. Results that were about 5% low were obtained by the dextran sulfate 500-Mg2+ (-25 mg/L) and phosphotungstate-Mg2+ (-31 mg/L) methods. A heparin-Ca2+ method produced results 10% high (+58 mg/L). Results by a polyethylene glycol-6000 precipitation method were 12% low (-64 mg/L). Precision was better with the two heparin-Mn2+ and the dextran sulfate 500-Mg2+ procedures, with CVs of 4%, intermediate with phosphotungstate-Mg2+ and polyethylene glycol-6000 (CV 6-7%), and poorest with heparin-Ca2+ (CV 10%). Precipitation by phosphotungate-Mg2+ appeared more sensitive to reagent concentration and temperature variations than either the heparin-Mn2+ or dextran sulfate 500-Mg2+ methods. We conclude that these precipitation methods are not equivalent, but give rise to significant systematic differences in high-density-lipoprotein cholesterol quantitation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Bonanome, A., Pagnan, A., Biffanti, S., Opportuno, A., Sorgato, F., Dorella, M., Maiorino, M., & Ursini, F. (1992) · Arteriosclerosis and Thrombosis: A Journal of Vascular Biology · doi:10.1161/01.atv.12.4.529 · Cited by 292
Borba, E., & Bonfá, E. (1997) · Lupus · doi:10.1177/096120339700600610 · Cited by 289
Precipitation methods for quantification of lipoproteins
Bachorik, P. S., & Albers, J. J. (1986) · Methods in Enzymology · doi:10.1016/0076-6879(86)29063-1 · Cited by 279
Self-citationDE PINIEUX, G., CHARIOT, P., AMMI‐SAÏD, M., LOUARN, F., LEJONC, J. L., ASTIER, A., JACOTOT, B., & GHERARDI, R. (1996) · British Journal of Clinical Pharmacology · doi:10.1046/j.1365-2125.1996.04178.x · Cited by 262
Cohen, J. C., Wang, Z., Grundy, S. M., Stoesz, M. R., & Guerra, R. (1994) · Journal of Clinical Investigation · doi:10.1172/jci117603 · Cited by 162
Arca, M., Zuliani, G., Wilund, K., Campagna, F., Fellin, R., Bertolini, S., Calandra, S., Ricci, G., Glorioso, N., Maioli, M., et al. (2002) · The Lancet · doi:10.1016/s0140-6736(02)07955-2 · Cited by 136
PHENOTYPE STUDY OF APOLIPOPROTEIN E ISOFORMS IN HYPERLIPOPROTEINAEMIC PATIENTS
Ghiselli, G., Zech, L., Gregg, R., Schaefer, E., & Brewer, H. B. (1982) · The Lancet · doi:10.1016/s0140-6736(82)90439-1 · Cited by 93
Gylling, H., Vega, G., & Grundy, S. (1992) · Journal of Lipid Research · doi:10.1016/s0022-2275(20)41407-5 · Cited by 67
Metadata
- Authors
- Warnick, G. R., Cheung, M. C., & Albers, J. J.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1979-04-01
- Volume
- 25
- Issue
- 4
- Pages
- 596-604
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W1524231207
- Cited by
- 224
- References
- 0
- FWCI
- 16.90
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.