CoChat

A simple, direct radioimmunoassay for plasma cortisol, featuring a 125I radioligand and a solid-phase separation technique.

Riad-Fahmy, D, Read, G F, Gaskell, S J, Dyas, J, Hindawi, R · 1979 · Clinical Chemistry
Cited by 74

The DOI matches its Crossref record.

Abstract

A simple, direct radioimmunoassay for cortisol in human serum and plasma is described. An antiserum, raised in sheep to a cortisol-3-(O-carboxymethyl)oxime/bovine serum albumin conjugate, is coupled to microcellulose. No extraction is required because plasma samples and standards are incubated with the antiserum and an 125I radioligand in a low-pH buffer, which denatures cortisol-binding globulins. The assay satisfies accepted validation criteria. In addition, results from the radioimmunoassay compare well with those obtained by a gas chromatographic-mass spectrometric technique (r = 0.968; FRIA = 0.97 FGCMS + 2.0 nmol/L). The latter procedure features the very high intrinsic specificity obtained by selected ion monitoring at high mass-spectrometric resolution (M/deltaM = 8500) with a Varian MAT-731 instrument. The simplicity of the radioimmunoassay procedure, with use of reagents prepared "in house," makes this a very practical and economical assay for use in the medium or large endocrine laboratory.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/clinchem/25.5.665

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 74

Metadata

Authors
Riad-Fahmy, D., Read, G. F., Gaskell, S. J., Dyas, J., & Hindawi, R.
Venue
Clinical Chemistry
Published
1979-05-01
Volume
25
Issue
5
Pages
665-668
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2121047543
Cited by
74
References
0
FWCI
5.84
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A simple, direct radioimmunoassay for plasma cortisol, featuring a 125I radioligand and a solid-phase separation technique. https://app.cochat.ai/papers/10.1093/clinchem/25.5.665
The paper
Riad-Fahmy, D., Read, G. F., Gaskell, S. J., Dyas, J., & Hindawi, R. (1979). A simple, direct radioimmunoassay for plasma cortisol, featuring a 125I radioligand and a solid-phase separation technique. Clinical Chemistry. https://doi.org/10.1093/clinchem/25.5.665

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.